AmScope B490

AmScope B490 Compound Binocular Microscope Instruction Manual

Model: B490

1. Izdelek je končanview

The AmScope B490 is a compound binocular microscope designed for biological and educational applications, offering high magnification and clear imaging. It features a sliding head for adjustable interpupillary distance, 10x widefield eyepieces, and a forward-facing nosepiece with four DIN achromatic objectives (4x, 10x, 40xS, 100xS oil). Illumination is provided by Brightfield halogen light with a rheostat for intensity control, paired with a 1.25 NA Abbe condenser and iris diaphragm. The microscope includes a double-layer mechanical stage z astage stop and graduated coarse and fine focus with tension control.

AmScope B490 Compound Binocular Microscope

Figure 1: AmScope B490 Compound Binocular Microscope, front-side view.

Vključene komponente:

  • AmScope B490 microscope with double-layer mechanical stage
  • 10x widefield eyepieces (one pair)
  • 4x DIN achromatic objective
  • 10x DIN achromatic objective
  • 40xS DIN achromatic objective
  • 100xS (oil) DIN achromatic objective
  • Immersion oil (one bottle)
  • Color filters (blue and green)
  • Spare halogen bulb
  • Rezervna varovalka
  • Navodila za uporabo
AmScope B490 Microscope Accessories

Figure 2: Included accessories: eyepieces, objectives, immersion oil, color filters, spare bulb, and fuse.

2. Navodila za nastavitev

  1. Razpakiranje: Previdno odstranite vse komponente iz embalaže. Originalno embalažo shranite za kasnejši transport ali shranjevanje.
  2. Umestitev: Place the microscope on a stable, level surface away from direct sunlight, excessive heat, dust, and vibrations.
  3. Glavni sklop: Loosen the head retaining screw on the microscope body. Gently insert the binocular head into the top opening, ensuring it is fully seated. Tighten the retaining screw to secure the head.
  4. Eyepiece Installation: Remove the protective caps from the eyepiece tubes and the eyepieces. Insert the two WF10x eyepieces into the binocular head's eyepiece tubes.
  5. Objective Installation: Rotate the revolving nosepiece until the 4x objective is positioned over the stage opening. Install the remaining objectives (10x, 40xS, 100xS oil) clockwise into the nosepiece.
  6. Napajalni priključek: Ensure the power switch is in the 'OFF' position. Connect the power cord to the microscope's power input and then to a suitable electrical outlet (110V).
AmScope B490 Microscope Side View

Slika 3: stran view of the microscope, showing focus knobs and power input location.

3. Navodila za uporabo

3.1 Power and Illumination

  1. Turn on the main power switch located on the base of the microscope.
  2. Adjust the illumination intensity using the rheostat knob on the side of the base. Start with a lower intensity and increase as needed for comfortable viewing.

3.2 Specimen Placement

  1. Rotate the revolving nosepiece to select the lowest power objective (4x).
  2. Dvignite stage using the coarse focus knob to create enough space to place the specimen slide.
  3. Odprite stage clips on the mechanical stage and carefully place the specimen slide, securing it with the clips.
  4. Uporabite XY stage control knobs to position the desired area of the specimen directly under the objective lens.
AmScope B490 Microscope Front View

Slika 4: Spredaj view of the microscope, highlighting the mechanical stage and objectives.

3.3 Fokusiranje in povečava

  1. Medzenična razdalja: While looking through the eyepieces, adjust the sliding head to match your eye distance until a single, circular field of view is observed. The range is 55 to 75mm.
  2. Dioptrična prilagoditev: If one eye is stronger than the other, use the diopter adjustment ring on one eyepiece to compensate, ensuring both eyes are in focus.
  3. Coarse Focus: Slowly lower the stage using the coarse focus knob until the specimen comes into rough focus.
  4. Fino ostrenje: Use the fine focus knob for precise focusing and to achieve a sharp image.
  5. Spreminjanje ciljev: To increase magnification, rotate the revolving nosepiece clockwise to the next objective (e.g., from 4x to 10x). Due to the parfocal design, only minor fine focus adjustments should be needed.
  6. Using 100xS Oil Immersion Objective: When using the 100xS objective, apply a small drop of immersion oil directly onto the specimen slide in the area to be viewed. Carefully lower the 100xS objective into the oil drop until it makes contact. Focus using the fine focus knob only. Always clean the 100xS objective and slide immediately after use to prevent oil from drying.
AmScope B490 Objectives and Stage Close-up

Slika 5: Bližnji posnetek view of the objectives and mechanical stage.

3.4 Condenser and Iris Diaphragm Adjustment

  1. The 1.25 NA Abbe condenser is mounted on a rack-and-pinion system, allowing its height to be adjusted. Raise or lower the condenser to optimize illumination for different objectives.
  2. The iris diaphragm lever controls the aperture of the light beam. Adjust it to achieve optimal contrast and resolution for the specimen and objective in use. Generally, a smaller aperture increases contrast but reduces resolution, while a larger aperture increases resolution but reduces contrast.

4. Vzdrževanje

4.1 Čiščenje

  • Optical Components: Use only specialized lens cleaning paper and lens cleaning solution. Gently wipe lenses in a circular motion. Avoid touching optical surfaces with bare hands.
  • Telo: Clean the microscope body with a soft, damp krpo. Izogibajte se uporabi močnih kemikalij ali topil.
  • Potopno olje: After using the 100xS oil immersion objective, immediately clean the objective lens and the specimen slide with lens cleaning solution to prevent oil residue from hardening.

4.2 Zamenjava žarnice

If the halogen illumination fails, the bulb may need replacement. Ensure the microscope is unplugged and the bulb has cooled before attempting replacement. Refer to the diagram in the original packaging for specific bulb access. Use the provided spare halogen bulb (6V/20W).

4.3 Zamenjava varovalke

If the microscope does not power on, check the fuse. Ensure the microscope is unplugged. The fuse holder is typically located near the power input. Replace with the provided spare fuse of the correct rating.

4.4 Shranjevanje

When not in use, cover the microscope with a dust cover to protect it from dust and debris. Store in a cool, dry place. The anti-mold surfaces help preserve optics in high-humidity environments, but proper storage is still recommended.

5. Odpravljanje težav

TežavaMožen vzrokrešitev
Brez osvetlitvePower cord disconnected, power switch off, bulb burnt out, fuse blownCheck power connection, turn on switch, replace bulb, replace fuse
Image is blurry/out of focusIncorrect focus, objective not fully engaged, dirty lenses, incorrect interpupillary distance/diopter settingAdjust coarse/fine focus, rotate nosepiece until objective clicks into place, clean lenses, adjust interpupillary distance/diopter
Insufficient contrastIris diaphragm too open, condenser height incorrectAdjust iris diaphragm to a smaller aperture, adjust condenser height
Dark spots in field of viewDust on eyepieces or objectives, dirty specimen slideClean eyepieces, objectives, and specimen slide
Stage not moving smoothlyStage lock engaged, debris in mechanismZagotovite stage lock is disengaged, clean stage area (consult professional if persistent)

6. Specifikacije

FunkcijaSpecifikacija
glavaCompound Binocular, Sliding Head, 30-degree inclination, 360-degree rotation
OkularjiWF10x
Cilji4x, 10x, 40xS (spring), 100xS (spring, oil) DIN Achromatic
Obseg povečave40X-1000X
StageDouble-layer Mechanical Stage (140 x 140mm), 75 x 45mm traveling range, 1mm divisions, Stage Stop
OsredotočanjeCoaxial Coarse and Fine Focus, 30mm focusing range, 0.002mm fine-focus divisions, Tension Control
OsvetlitevTransmitted (lower) Brightfield Halogen with Rheostat (6V/20W)
Kondenzator1.25 NA Abbe Condenser with Iris Diaphragm, Rack-and-Pinion Control
Medzenična razdalja55-75 mm
Moč110V (US standard)
Dimenzije (V x Š x G)16 x 9 x 12 palcev (približno)
Teža15.32 funta (približno)
MaterialSolid-metal enamel-coated body, optical glass components
Posebne lastnostiAnti-mold surfaces

7. Garancija in podpora

For warranty information, technical support, or service inquiries, please refer to the official AmScope website or contact AmScope customer service directly. Details regarding specific warranty periods and support procedures are typically provided with your purchase documentation or on the manufacturer's official channels.

Manufacturer: AmScope

Headquarters: Irvine, CA, USA

Povezani dokumenti - B490

Prejview Uporabniški priročnik za mikroskop AmScope serije 120
Obsežen uporabniški priročnik za mikroskope AmScope serije 120 (B120 in T120), ki zajema nastavitev, delovanje, specifikacije in odpravljanje težav.
Prejview Navodila za uporabo sestavljenega mikroskopa AmScope serije 490
Ta navodila za uporabo vsebujejo obsežna navodila za sestavljeni mikroskop AmScope serije 490, ki zajemajo nastavitev, delovanje, vzdrževanje in odpravljanje težav za optimalno uporabo.
Prejview Uporabniški priročnik za sestavljeni mikroskop AmScope serije 490 | Uporabniški priročnik
This operator's manual provides comprehensive instructions for the AmScope 490 Series Compound Microscope, covering setup, operation, maintenance, troubleshooting, and specifications. Learn to use your AmScope microscope effectively with this detailed guide.
Prejview Uporabniški priročnik za stereo mikroskop AmScope serije PM240
Uporabniški priročnik za stereo mikroskope AmScope serije PM240, ki zajema nastavitev, delovanje, specifikacije in odpravljanje težav za binokularne in trinokularne modele.
Prejview Uporabniški priročnik za mikroskop AmScope serije 120
Obsežen uporabniški priročnik za mikroskope AmScope serije 120, ki zajema nastavitev, delovanje, specifikacije in odpravljanje težav za modele, kot sta B120 in T120.
Prejview Uporabniški priročnik za mikroskop AmScope serije M150
Uporabniški priročnik za mikroskope AmScope serije M150, ki zajema nastavitev, delovanje, vzdrževanje, specifikacije in odpravljanje težav.