sindcon RS485 Modbus LoRaWAN Bridge User Manual

Product Overview

Sindcon’s Neptune series Modbus-LoRaWAN bridge is an affordable solution for converting traditional wired Modbus devices into Lo RaWAN wireless nodes. It enables reading and writing of any register of the connected Modbus device through the Lo RaWAN. The configuration of Modbus register mapping of the Modbus-LoRaWAN bridge device can be easily done remotely from the Sindcon LoRaWAN server by downlink commands. Moreover, users can use the Mobile App (Busy Box) which are available from Apple Store and Google Store, to configure the device to different Modbus devices on field.

Features

  • AC Power Supply with wide input range (85V to 250V)
  • LoRa SoC (STM32WLESXX) integrating ARM.
  • Cortex-M4 Core as processor
  • Compliant with standard Modbus Protocol
  • Compliant with Standard LoRaWAN Protocol 1.0.3
  • Remotely configuration of Modbus register mapping from mobile APP
  • Maximum upload data size can be up to 128 bytes by utilizing the Sindcon LoRaWAN Server

Product Diagrams and Installation


DIN rail installation

Installation Instructions

Pin Description
ANT Antenna port
RST Reset Botton
A RS485-A(+)
B RS485-B(-)
L 220V-L
N 220V-N
NC No Connection

Install the RS485_LoRa Bridge Model NPL-IN(AC) on the Energy Meter and connect the cables, follow the steps below:
Step 1: Connect to Energy Meter (Modbus Port):

  • Locate the RS485_LoRa Bridge Model NPL-IN(AC).
  • Identify the upper port on the RS485_LoRa Bridge, labeled as “Modbus Port” (AB).
  • Connect one end of a suitable RS485 cable to the Modbus Port (AB) of the RS485_LoRa Bridge.
  • Connect the other end of the RS485 cable to the corresponding Modbus communication port on the Energy Meter.

Step 2: Power Supply Connection:

  • Find the lower port on the R5485_LoRa Bridge, labeled as “Power Supply Port.”
  • Connect the power supply source. Port on the RS485_LoRa Bridge. Ensure that the voltage and current rating of the power supply match the requirements of the RS485_LoRa Bridge.

Step 3: Install the Antenna,

  • Locate the antenna port on the RS485_LoRa Bridge, situated on top.
  • Connect the provided antenna to the Antenna Port securely. The antenna is crucial for establishing wireless  communication between the RS485_LoRa Bridge and other LoRa devices.

Step 4: Check Connections and Power Up:

  • Double-check all the connections to make sure they are correctly installed according to the connection definitions.
  • Ensure that the RS485 cable is securely connected to both the RS485_LoRa Bridge and the Energy Meter.
  • Confirm that the power supply is correctly connected to the Power Supply Port.
  • Verify that the antenna is securely attached to the Antenna Port.
  • Once everything is in place, power on the RS485_LoRa Bridge by turning on the connected power supply.

Multi-Protocol LoRaWAN Bridge NPL-IN (AC)

DESCRIPTION

Powered by ARM Cortex-M4 Core integrated in LoRa SoC, Sindcon’s Neptune series Multi-Protocol LoRaWAN Bridge is an affordable solution for converting traditional wired Modbus devices into LoRaWAN wireless nodes. It enables reading and writing of any register of the connected Modbus device through the LoRaWAN. The configuration of Modbus register mapping of the Multi-Protocol LoRaWAN Bridge device can be easily done remotely from the Sindcon LoRaWAN server by downlink commands. Moreover, users can use the Mobile App (Busy Box) which are available from Apple Store and Google Store, to configure the device to different Modbus devices on field.

FEATURES AND BENEFITS

Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.

  • AC Power Supply with wide input range (85V to 250V)
  • LoRa SoC (STM32WLE5XX) integrating ARM
  • Cortex-M4 Core as processor
  • Compliant with standard Modbus Protocol
  • Compliant with Standard LoRaWAN Protocol 1.0.3
  • Remotely configuration of Modbus register mapping from mobile APP
  • Maximum upload data size can be up to 128 bytes by utilizing the Sindcon LoRaWAN Server
  • Provide support for local server alarms

TECHNICAL PARAMETER

Electrical Parameters
Power Supply 85V-250V AC
Standby Current 54mA
TX Current 80mA
MCU Arm® 32-bit Cortex®-M4
Memories 256KB Flash: 64KB RAM
LoRaWAN Parameters
LoRaWAN Class Class C
ISM Band AS923, AU915, EU868
RX Sensitivity Down to -125dBm@BW = 125 kHz. SF = 7
Channels 16
Spreading Factor SF7-SF10 (adaptive)
LBT(Listen Before Talk) Yes
Number of Data cached when wireless network interrupted 10*

*Can be configured and need to consult Sindcon for details

7 Tampines Industrial Drive, #03-01 Zulin Building, Singapore 528547
+65 69095529
sales@sindcon.com.sg
www.sindcon.com.sg

Documents / Resources

sindcon RS485 Modbus LoRaWAN Bridge [pdf] User Manual
ST0301, 2BHSMST0301, RS485 Modbus LoRaWAN Bridge, RS485, Modbus LoRaWAN Bridge, LoRaWAN Bridge, Bridge

References

Leave a comment

Your email address will not be published. Required fields are marked *