Simx LogoInstruction Manual

Window Fans – SELV and Auto Shutter

These fans are designed for installation situations where an existing window fan is being replaced or where there is no available external wall, or ceiling, space access. SELV fans are designed for use in wet area zones 1, 2 and 3 and incorporate a 12V AC motor and a 12V AC isolating transformer. Auto shutter models have automated backflow prevention vanes. 5 year warranty.

Simx WF100PLV Window Fans And Auto Shutter

Note: Installed system performance is always influenced by duct length and layoutc
Electrically operated louvre shutters open automatically when fan is running – prevents backdraughts.

Switching Options

Standard Remote switch (not supplied).
Pull Cord Timer Pull cord is integral part of fan. Fan continues operating for 7 minutes after switching off.
Pull Cord Integral part of fan.
Standard/Auto Remote switch (not supplied) and internal thermo-activation of shutters
Standard/Pull Cord Remote switch (not supplied) and manual operation of shutters by pull cord

Dimensions (mm)

Model Cut-Out Size A B C

D

WF300 310-345 362 4-32 112 29
WF230 255-270 286 4-32 112 25
WF150 165-190mm 203 125 23
WF100 115-155mm 163 120 30
COM300 310-345 362 170 145 25
COM230 255-270 286 154 125 25

Simx WF100PLV Window Fans And Auto Shutter - Figure

Technical

Supply SELV 12V AC
Auto Shutter 220-240V AC, 50Hz
Max. Operating Temp 50°C
IP Rating IPX4

www.simx.co.nz