Simx-LOGO

Simx FAN6085 New Humidity Sensor

Simx-FAN6085-New-Humidity-Sensor-PRODUCT

Specifications

  • Product Name: ULTECON Humidistat (UT-H1)
  • Order Code: FAN6085
  • Compatibility: Only compatible with AC wire wound fans
  • Power Supply: 230V / 50Hz
  • Suggested Use: Ideal for environments prone to mold like bathrooms, laundries, kitchens

Product Usage Instructions

Mounting and Installation:

  1. Remove the terminal cover to access the terminals for wiring.
  2. Connect the 230V / 50Hz mains cable to terminals N and L (the first two on the right).
  3. Connect terminals labelled N and OUT to the device you want to operate, e.g., fan (Scheme #1).
  4. Terminal labelled as 1 may be connected for separate switching of the fan (Scheme #2).
  5. After connecting the wires, install back cover on Humidistat terminals.

Settings

  • Set Up for Damp Conditions: Adjust the dial until the RED light comes on. Ventilation will run until humidity is reduced. Re-adjust if required.
  • Set Up for Dry Conditions: In low humidity environments adjust the dial until the RED light comes on and then turn it back until the RED light goes off. Re-adjust if required.

Suggested Products:

The ULTECON Humidistat (UT-H1/FAN6085) is recommended for use with:

  • Manrose Wall/Ceiling fans & kits
  • Manrose In-line fans & kits
  • Manrose (SELV) Safety Extra Low Voltage fans & kits
  • ULTECON Thermostats (UT-M1 and UT-T1)

Contact Information:

Distributed by: Simx Limited
Ph: +64 9 259 1660 | Tech Ph: +64 9 259 1662
Email: sales@simx.co.nz | Website: www.simx.co.nz

Simx reserves the right to alter technical specifications without prior warning

Frequently Asked Questions

Q: Can this humidistat be used with DC fans?

A: No, this humidistat is only compatible with AC wire wound fans.

Q: How do I know if the ventilation is running?

A: When the RED light on the humidistat comes on, it indicates that the ventilation is running.

ULTECON Humidistat (UT-H1)
Order Code: FAN6085
The ULTECON Humidistat is an ideal solution for environments where there is a high risk of mould occurring e.g., bathrooms, laundries, kitchens. The function of FAN6085 is to maintain the relative humidity (RH) level
in a room by controlling a ventilation device.
Note: Relative Humidity (RH) is the percentage of water vapour content in the air versus air fully saturated with water vapour at the same temperature.

Components

Simx-FAN6085-New-Humidity-Sensor-FIG-1

Settings
Set Up for Damp Conditions: In high humidity environments adjust the dial until the RED light comes on. Ventilation will run until humidity is reduced. Re-adjust if required.

Set Up for Dry Conditions:
In low humidity environments adjust the dial until the RED light comes on and then turn it back until the RED light goes off. Re-adjust if required.

Suggested Products
The Ultecon Humidistat (UT-H1/FAN6085) is recommended for use with Manrose Wall/Ceiling fans & kits, Manrose In-line fans & kits, Manrose (SELV) Safety Extra Low Voltage fans & kits and the Ultecon Themostats (UT-M1 and UT-T1).

Only compatible with AC wire wound fans

Mounting
Remove the terminal cover (Fig.1). Connect 230V / 50Hz mains cable to terminals N and L (the first two on the right). Connect terminals labelled N and OUT to the device you want to operate, e.g., fan (Scheme #1). Terminal labelled as 1 may be connected for separate switching of the fan (Scheme #2). After connecting the wires, install back cover on Humidistat terminals.

Installation Scheme

Simx-FAN6085-New-Humidity-Sensor-FIG-2

Important Notice

  • When replacing the fuse always use type F2 Amp, 250V.
  • Isolate the mains supply before making any electrical connections.
  • This system should be installed by a qualified electrician.
  • Humidistat should only be installed by fixed wiring, a flexible cord should not be used.
  • The appliance is not intended for use by young children or infirm persons without supervision.

Simx reserves the right to alter technical specifications without prior warning

Distributed by: Simx Limited
Ph: +64 9 259 1660 | Tech Ph: +64 9 259 1662 Email: sales@simx.co.nz | www.simx.co.nz

Documents / Resources

Simx FAN6085 New Humidity Sensor [pdf] Instruction Manual
FAN6085, FAN6085 New Humidity Sensor, FAN6085, New Humidity Sensor, Humidity Sensor, Sensor

References

Leave a comment

Your email address will not be published. Required fields are marked *