simplehuman PD6309 Rectangular Sensor

Lid assembly PD6254
for ST2031 rectangular sensor can
Tools you need:
small flathead screwdriver
video guide
Removing Lid
- Remove batteries or AC adapter from the sensor can.
Wave hand over sensor to make sure there is no power.
- Open lid and liner rim and push back until it is locked into place.

- Insert screwdriver between the lid and panel, then push the screwdriver down to unlock the panel.

- Remove inner panel around the lid.

- Unplug connector from the electronic board.

- Unhook wire from its groove.

- Use screwdriver to slide tabs toward the center. Make sure both tabs have been moved to their end-most positions.

- Firmly grasp lid assembly and pull it upward.

Installing Lid
- Remove inner panel from the new lid assembly. Place new lid assembly onto the sensor can in the open position.

- Slide tabs outward using screwdriver. Start with the left side first. Tip: You may need to constantly adjust lid while sliding the right tab.

- Hook wire through its groove.

- Plug connector into the electronic board.

- Place inner panel back into lid. Make sure panel snaps into place.

- Close lid and insert batteries or connect AC adaptor.

Final Result