SIMARINE SN01 N2K Gateway
Specifications
- Operating Voltage Range: N2K backbone Connectivity
- Temperature range: 0,6 mA
- Power consumption at 12V: 111.80 x 77.52 x 32.11 mm / 4.40 x 3.05 x 1.26 in
- Operating Dimensions: 1 SiCOM
FAQs
- Q: What PGNs are supported by the SN01 N2K Gateway?
- A: The SN01 N2K Gateway supports various PGNs including ISO Request, ISO Address Claim, Product Information, Attitude, Switch Bank Control, Fluid Level, DC Detailed Status, Battery Status, Environmental Parameters, and Actual Pressure. Refer to the manual for detailed information on transmitting and receiving capabilities for each PGN.
- Q: What is the recommended cable type for SiCOM connection?
- A: For the SiCOM connection, it is recommended to use a 2 x 2 x 0.25 mm2 Twister pair cable, especially for cable lengths greater than or equal to 5 meters.
Introduction
Simarine’s SN01 SiCOM N2K Gateway module allows your PICO to transmit data.
Safety
- Electrical specialists with proper safety equipment should make installation of Simarine electronics. When working with batteries, you should wear protective clothing and eye protection.
- CAUTION: Batteries contain acid, a corrosive, colorless liquid that will burn your eyes, skin, and clothing. Should the acid come in contact with eyes, skin, or clothing, wash it immediately under fresh water for at least 15 minutes, and seek medical support immediately.
- CAUTION: Do NOT connect anything to a damaged battery. It could heat up, catch fire, or explode.
- CAUTION: Lead-acid batteries can generate explosive gases during operation. Never smoke, allow flames or sparks near the battery. Make sure to keep sufficient ventilation around the battery.
Schematics
Overview
- A – 1x N2K port
- B – 2x SiCOM port
List of supported N2K PGN
Below is a list of supported N2K PGN’s. PICO allows the transmitting or receiving of certain PGN according to the table below.
Installation
Mounting
CAUTION: install the shunt module in a clean dry place, protected from accidental spilling of liquids.
- You can mount the module with the supplied screws using two holes on both sides of the module.
- Connect all cables.
Cables
For the SiCOM connection use the supplied cable. If not possible, use the following table to determine the right cable type.
Cable length Cable type | |
< 5m No limitations | |
>= 5m | 2 x 2 x 0.25 mm2 Twister pair |
(recommended) |
Note: Minimum power cable cross-section requirement at maximal temperature of insulation 70 °C (160 °F).
Connecting
For the proper function of Simarine’s SN01 N2K gateway module it is necessary to take the following steps:
- Connect SN01 to Simarine PICO via the SICOM port
- Connect to the N2K backbone via the marked N2K port connector
- PICO manual & other user manuals: https://simarine.net/support/.
Technical specifications
Operating | |
Voltage range | 6 – 35 V |
Temperature range | -20°C – 70°C (-4°F – 158°F) |
Power consumption at 12V | |
Operating | 0,6 mA |
Dimensions | |
SN01 N2K Gateway | 111.80 x 77.52 x 32.11 mm |
4.40 x 3.05 x 1.26 in | |
N2K backbone | 1 |
Connectivity | SiCOM |
Documents / Resources
![]() |
SIMARINE SN01 N2K Gateway [pdf] User Manual SN01 N2K Gateway, SN01, N2K Gateway, Gateway |