SIMARINE SN01 N2K Gateway

SIMARINE-SN01-N2K-Gateway-PRODUCT

Specifications

  • Operating Voltage Range: N2K backbone Connectivity
  • Temperature range: 0,6 mA
  • Power consumption at 12V: 111.80 x 77.52 x 32.11 mm / 4.40 x 3.05 x 1.26 in
  • Operating Dimensions: 1 SiCOM

FAQs

  • Q: What PGNs are supported by the SN01 N2K Gateway?
    • A: The SN01 N2K Gateway supports various PGNs including ISO Request, ISO Address Claim, Product Information, Attitude, Switch Bank Control, Fluid Level, DC Detailed Status, Battery Status, Environmental Parameters, and Actual Pressure. Refer to the manual for detailed information on transmitting and receiving capabilities for each PGN.
  • Q: What is the recommended cable type for SiCOM connection?
    • A: For the SiCOM connection, it is recommended to use a 2 x 2 x 0.25 mm2 Twister pair cable, especially for cable lengths greater than or equal to 5 meters.

Introduction

Simarine’s SN01 SiCOM N2K Gateway module allows your PICO to transmit data.

Safety

  • Electrical specialists with proper safety equipment should make installation of Simarine electronics. When working with batteries, you should wear protective clothing and eye protection.
  • CAUTION: Batteries contain acid, a corrosive, colorless liquid that will burn your eyes, skin, and clothing. Should the acid come in contact with eyes, skin, or clothing, wash it immediately under fresh water for at least 15 minutes, and seek medical support immediately.
  • CAUTION: Do NOT connect anything to a damaged battery. It could heat up, catch fire, or explode.
  • CAUTION: Lead-acid batteries can generate explosive gases during operation. Never smoke, allow flames or sparks near the battery. Make sure to keep sufficient ventilation around the battery.

Schematics

SIMARINE-SN01-N2K-Gateway-FIG- (1)

Overview

SIMARINE-SN01-N2K-Gateway-FIG- (2)

  • A – 1x N2K port
  • B – 2x SiCOM port

List of supported N2K PGN

Below is a list of supported N2K PGN’s. PICO allows the transmitting or receiving of certain PGN according to the table below.

SIMARINE-SN01-N2K-Gateway-FIG- (3)

Installation

Mounting
CAUTION: install the shunt module in a clean dry place, protected from accidental spilling of liquids.

  1. You can mount the module with the supplied screws using two holes on both sides of the module.
  2. Connect all cables.

Cables

For the SiCOM connection use the supplied cable. If not possible, use the following table to determine the right cable type.

Cable length                                           Cable type
< 5m                                                        No limitations
>= 5m 2 x 2 x 0.25 mm2 Twister pair
(recommended)

Note: Minimum power cable cross-section requirement at maximal temperature of insulation 70 °C (160 °F).

Connecting

For the proper function of Simarine’s SN01 N2K gateway module it is necessary to take the following steps:

  1. Connect SN01 to Simarine PICO via the SICOM port
  2. Connect to the N2K backbone via the marked N2K port connector

Technical specifications

Operating  
Voltage range 6 – 35 V
Temperature range -20°C – 70°C (-4°F – 158°F)
Power consumption at 12V  
Operating 0,6 mA
Dimensions  
SN01 N2K Gateway 111.80 x 77.52 x 32.11 mm
  4.40 x 3.05 x 1.26 in
N2K backbone 1
Connectivity SiCOM