SHOWVEN SPARKULAR Waver Fall
Specifications:
- Manufacturer: Showven Technologies Co., Ltd.
- Model: HC8200
- Max. Effect Height:
- LARGE: 4m (Safety Radius: 5m, Safety Distance at Firing Direction: 1.5m)
- LARGE I: 5m (Safety Radius: 6m, Safety Distance at Firing Direction: 1.5m)
- LARGE II: 7m (Safety Radius: 8m, Safety Distance at Firing Direction: 1.5m)
Product Usage Instructions
Safety Instructions:
- Ensure a safety radius around the machine of 1.5m. No person or flammable materials should be within this radius.
- In windy environments, adjust the safety distance based on wind direction and speed.
- Always wear safety goggles when entering the safety zone to protect against eye injuries from sparks and consumables.
Operation Panel:
Use the keypad area to navigate through the menu options:
- MENU: Press to enter the settings interface
- UP: Move parameter values up
- DOWN: Move parameter values down
- MONI: Monitor the status of the main parts inside the machine
Display Interface:
The main interface provides information on the machine’s status:
- Red background color in DMX area indicates DMX connection
- Red background color in TEMP area indicates heating chamber temperature has reached the set temperature
- Indicator light status on power switch provides information on heating up and readiness for firing
Set Up Menu:
To access the setup menu, press MENU. Navigate through the menus using LEFT and RIGHT buttons. Press EDIT to enter specific menus and adjust parameters. Remember to press SAVE to save the settings.
FAQ:
- Q: What should I do if the machine displays an error code?
A: Refer to the error code explanations provided in the manual. For example, E0 indicates a systematic error, E1 relates to motor conditions, and so on. Follow the instructions to troubleshoot or seek professional assistance if needed.
USER MANUAL
SPARKULAR® waverFALL
V1.1
2024/07/02
Showven Technologies Co., Ltd.
Thanks for choosing SPARKULAR® waverFALL, we wish it will sparks up your show. Please read the following manual carefully before operating this product.
Safety Instructions
- Unauthorized repair are prohibited, it may cause serious incident.
- SPARKULAR® waverFALL can be used in rain, please keep the device dry after use.
- Make sure lid of feeding hopper are well covered when use SPARKULAR® waverFALL.
- Consumable should keep away from moisture and stored in a dry sealed environment.
- Check whether there is consumable aggregate in the output nozzle both before and after each show, if any, please clean it up, or it will affect the firing effect, damage machine, even cause serious incident.
- There will be some sparks drop to ground, make sure there are no flammable objects such as carpet on the ground within the safety radius of the machine.
- The SPARKULAR® waverFALL power supply cable maximum allowed cascade of 6pcs (220V version) / 3pcs (110V version), exceed connecting may result in damage or even cause fire.
- Cover the output nozzle of SPARKULAR® waverFALL is forbidden, inspect the machine before each show, making sure no objects or material will block the output nozzle.
- Never touch the nozzle of SPARKULAR® waverFALL danger of getting burnt.
- Never touch the sparks which shooting out from the nozzle.
- Make sure no staff, audience and flammable materials stays under the SPARKULAR® waverFALL.
Safety Distance
- Safety distance for SPARKULAR® waverFALL divided into two parts safety radius around machine (a) and safety distance at firing direction (b). No person and flammable materials are allowed to stay inside the safety isolation zone when SPARKULAR® waverFALL was armed.
- The safety radius around machine of 1.5m.
- For safety distance at firing direction equals to maximum firing height + 1m. SPARKULAR® waverFALL with maximum 90 waving firing angles, when firing wave sequence the safety isolation zone is a three-dimensional sector area.
HC8200 Type | Max. Effect Height | Safety Radius around SPARKULAR (a) | Safety Distance at Firing Direction (b) |
LARGE | 4m |
1.5m |
5m |
LARGE I | 5m | 6m | |
LARGE II | 7m | 8m |
- The SPARKULAR® WAVERFALL safety isolation zone is a three-dimensional space with a cross- section of 180° sector enclosed by a and b (check below diagram). We can understand it as a safety area formed by a safety column with diameter of a, height of b rotate of ±90 degrees. Unauthorized persons and objects are strictly prohibited from entering. Depending on the firing sequence / angles the sector area changes accordingly.
- In windy environment, increase the safety distance according to the wind direction and speed.
- Sparks and consumables from the machine can lead to serious eye injury. Always wear safety goggles when enter the safety zone.
Description
SPARKULAR® waverFALL is 180°waving spark fall effect originally developed by SHOWVEN. It can firing in any single direction between -90° to 90° or in waving sequences. With 72 preset firing sequences and various editable sparks effect brings infinite creativity to your stage. It can also combined with SPARKULAR WAVER to generate a spark effect in any direction of 360 degrees.]
Technical Specifications
- DIMENSION: 309 305 285mm
- WEIGHT: 17kg
- VOLTAGE: AC200-240V / AC100-120V, 50/60Hz
- WORK POWER: 500W
- HC8200 CONSUMPTION: 22g/min
- EFFECT HEIGHT ADJUSTBLE: YES
- EFFECT ANGLE ADJUSTBLE: -90°~ 90° (180° waving angles)
- INTERFACE: 3-pin and 5-pin XLR, POWER IN/OUT
- CONTROL: 6 DMX channels
- WORK TEMP.: -20 C~40 C
- CONSUMABLE AND EFFECT HEIGHT: LARGE (3-4m), LARGE I (4-5m), LARGE II (5-7m)
Structure of SPARKULAR® waverFALL
- Feeding Hopper Lid
- Clamp
- ARM alarming light
- Display Screen
- Power Switch
- Fuse
- Power IN
- Power OUT
- 3-PIN DMX OUT
- 3-PIN DMX IN
- 5-PIN DMX OUT
- 5-PIN DMX IN
Operation Panel
- Keypad area
- MENU: Press enter setting interface
- UP: Parameter up
- DOWN: Parameter down
- MONI: Status monitoring of main part inside machine
- Monitoring Interface
From this interface, we can check the voltage and motor status of machine. - RFID area
RFID card come with consumable HC8200 bags, swiping card to identify parameters and types of granules. The RFID card is disposable, one card can only use one time. Each card can increase single machine 20min working time, the maximum recharge time for SPARKULAR® waverFALL is 30min. - ARM alarming light
- ON: DMX connected or wireless remote function
- ON. BLINK: DMX armed, ready for firing
- OFF: No DMX connection and wireless remote function OFF.
Display Interface
- Main Interface:
- Background color of DMX area: red means DMX connected.
- Background color of TEMP area: red means heating chamber temp. reached setting temp. machine is ready for firing.
- Indicator light status on power switch: flash means machine is heating up, long on means temp. reached setting temp.
Error information
Error information | Explanation |
E0 System IC | Systematic error |
E1 Motor condition | Blower motor, shaft motor or feeding motor error |
E2 Temp. Sensor | Temperature sensor is not connected or damaged |
E3 P Temp. Over | Machine shutdown due to chassis over temperature |
E4 Time Remain | Firing time is insufficient, please swipe RFID card |
E5 K Temp. Over | Machine shutdown due to heating chamber over temperature |
E6 Heat Fail | Heating fail, problem on heating PCB or mainboard, if disappear automatically, please check the power supply. |
E7 Tip Over | Tilt sensor activated when machine slant over 45 degrees |
Set Up Menu
Press “MENU” enter setup menu, press LEFT, RIGHT to choose main menu, advanced menu or factory menu. Press “EIDT” can entering related menu and setting up related parameters.
Main Menu
Parameters in main menu show in below table, press “UP”/ “DOWN” to change the value, please remember to press “SAVE” to save the setting.
Options | Range | Default | Explanation |
Set DMX Address | 1-512 | 1 | Set DMX Address |
Manual Heat | ON/OFF | OFF | Manual heat ON/OFF setting |
Manual Fountain | ON/OFF | OFF | Manual Fountain ON/OFF setting |
Sequence | 2 – 72 | 2 | Preset sequence setting |
Max. Angle | 0°~90° | 90° | Max. Angle limit |
Min. Angle | -90°~0° | -90° | Min. Angle limit |
Invert | ON/OFF | OFF | When turned on, all angles will be mirrored. |
Head to middle |
ON/OFF |
ON |
When ON and Channel 1 DMX value is 0, output
nozzle will back to middle position after running a preset sequence. |
Advanced Menu
Options | Range | Default | Explanation |
Set Temperature | 400-620 | 580 | Setup SPARKULAR® heat chamber temperature |
Auto Clear Delay | 0.1-0.9s | 0.1s | Automatic clear material time setting |
Wireless 2.4G | ON/OFF | OFF | 2.4G wireless function setting |
LCD Backlight | ON/OFF | ON | LCD backlight setting |
Density | 70-100 | 100 | Feeding amount |
Mode Selection |
Factory Mode User Mode |
User Mode |
Factory mode is for engineer only. When in Factory mode machine
can’t controlled by DMX console |
Default Parameter | ON/OFF | OFF | Parameters reset to default setting |
Motor Protect | ON/OFF | ON | Motor protect function |
Tip Over |
ON/OFF |
ON |
Tilt function switch, when machine slant over 45 degree it will stop
working. |
Standby Switch | ON/OFF | OFF | When ON, the machine can firing only when heating up was finished |
Motor Disabled | ON/OFF | OFF | Motor can’t waving when OFF |
Key Sound | ON/OFF | ON | Keypad press sound setting |
Middle Set |
ON/OFF |
OFF |
When it is ON, after firing nozzle will move to around 15 degree and then back to middle slowly |
*For better performance of SPARKULAR® waverFALL, please don’t change the default value without permission from SHOWVEN® .
DMX Channel Mode
SPARKULAR waverFALL occupies 6 operational channels.
Channel | Function | Value |
CH1 | Manual Angle setup | 0~255: angle change from -90° to 90°
128: straight upward (0°) |
CH2 | Manual Nozzle
Waving Speed setup |
0 and 255: Max Speed
1~254: Speed increase |
CH3 |
Firing ON/OFF |
0~15: Firing OFF
16~90: Firing height low 91~170: Firing height medium 171~255: Firing height high Maxi. Single firing duration is 60s |
CH4 | n/a | Reserved |
CH5 |
Preset sequence setup |
0-2: no preset sequence 3-255: preset sequence
DMX value = 2 + Sequence No.*2.55 (ROUND OFF) |
CH6 |
Mode setup |
0~49: Heating Up OFF (Emergency Stop) 50~200: Heating Up ON
201~255: Heating Up OFF (Emergency Stop) |
Channel 1 (CH1): Manual Angle Setup
SPARKUALR waverFALL output nozzle can be stayed at any angle between -90° to 90°, below is a list of typical angles used in our preset sequence with related DMX value.
Angle No. | Angle | DMX value |
1 | -90° | 5 |
2 | -75° | 24 |
3 | -60° | 47 |
4 | -45° | 66 |
5 | -30° | 85 |
6 | -15° | 108 |
7 | 0° | 128 or 0 |
8 | 15° | 148 |
9 | 30° | 169 |
10 | 45° | 190 |
11 | 60° | 213 |
12 | 75° | 234 |
13 | 90° | 255 |
Angle Definition
SPARKUALR waverFALL with waving output nozzle firing between -90° to +90°, we divided 180 degree into 13 firing directions as below (audience side view).
Channel 5 (CH5): Firing Sequence
SPARKULAR waverFALL has 72 preset sequences, operator use related channel DMX value or sequence No. to access certain sequence. Below, you can find sequence list.
No. |
Ignition angle |
Description |
Firing Duration |
CH5 DMX
Reference Value |
1 | Any angle | Clear material | Depends on CH3 | 3-5 |
2 | -90° | Fixed angle firing | Depends on CH3 | 6-7 |
3 | -75° | Fixed angle firing | Depends on CH3 | 8-10 |
4 | -60° | Fixed angle firing | Depends on CH3 | 11-12 |
5 | -45° | Fixed angle firing | Depends on CH3 | 13-15 |
6 | -30° | Fixed angle firing | Depends on CH3 | 16-17 |
7 | -15° | Fixed angle firing | Depends on CH3 | 18-20 |
8 | 0° | Fixed angle firing | Depends on CH3 | 21-22 |
9 | 15° | Fixed angle firing | Depends on CH3 | 23-25 |
10 | 30° | Fixed angle firing | Depends on CH3 | 26-28 |
11 | 45° | Fixed angle firing | Depends on CH3 | 29-30 |
12 | 60° | Fixed angle firing | Depends on CH3 | 31-33 |
13 | 75° | Fixed angle firing | Depends on CH3 | 34-35 |
14 | 90° | Fixed angle firing | Depends on CH3 | 36-38 |
15 | (-90°) ~ 90° | Slow waving once | 8s | 39-40 |
16 | 90°~ (-90°) | Slow waving once | 8s | 41-43 |
17 | (-90°)~ 90° ~(-90°) | Slow waving once | 14s | 44-45 |
18 | (-75°)~ 75°~ (-75°) | Slow waving once | 12s | 46-48 |
19 | (-60°)~ 60° ~ (-60°) | Slow waving once | 10s | 49-50 |
20 | (-45°)~ 45° ~ (-45°) | Slow waving 3 times | 17s | 51-53 |
21 | (-30°)~ 30° ~ (-30°) | Slow waving 3 times | 12s | 54-56 |
22 | (-15°)~ 15° ~ (-15°) | Slow waving 3 times | 7s | 57-58 |
23 | (-90°)~ 90° ~ (-90°) | Medium waving 5 times | 12s | 59-61 |
24 | (-75°)~ 75° ~ (-75°) | Medium waving 5 times | 10s | 62-63 |
25 | (-60°)~ 60° ~ (-60°) | Medium waving 5 times | 8s | 64-66 |
26 | (-45°)~ 45° ~ (-45°) | Medium waving 5 times | 7s | 67-68 |
27 | (-30°)~ 30° ~ (-30° | Medium waving 5 times | 5s | 69-71 |
28 | (-15°)~ 15° ~ (-15°) | Medium waving 5 times | 3s | 72-73 |
29 | (-60°)~ 60° ~ (-60°) | Fast waving 10 times | 5s | 74-76 |
30 | (-45°)~ 45° ~ (-45°) | Fast waving 10 times | 5s | 77-79 |
31 | (-30°)~ 30° ~ (-30°) | Fast waving 10 times | 4s | 80-81 |
32 | (-15°)~ 15° ~ (-15°) | Fast waving 10 times | 3s | 82-84 |
33 | (-75°)~ 0° ~ (-75°) | Fast waving 10 times | 4s | 85-86 |
34 | (-60°)~ 0° ~ (-60°) | Fast waving 10 times | 3s | 87-89 |
35 | (-45°)~ 0° ~ (-45°) | Fast waving 10 times | 2s | 90-91 |
36 | (-30°)~ 0° ~ (-30°) | Fast waving 10 times | 2s | 92-94 |
37 | 75° ~ 0° ~ 75° | Fast waving 10 times | 5s | 95-96 |
38 | 60° ~ 0° ~ 60° | Fast waving 10 times | 4s | 97-99 |
39 | 45° ~ 0° ~ 45° | Fast waving 10 times | 3s | 100-101 |
40 | 30° ~ 0° ~ 30° | Fast waving 10 times | 3s | 102-104 |
41 | (-90°)~ 0° ~ (-90°) | Slow waving twice | 11s | 105-107 |
42 | (-75°)~ 0° ~ (-75°) | Slow waving twice | 10s | 108-109 |
43 | (-60°)~ 0° ~ (-60°) | Slow waving twice | 8s | 110-112 |
44 | (-45°)~ 0° ~ (-45°) | Slow waving twice | 6s | 113-114 |
45 | (-30°)~ 0° ~ (-30°) | Slow waving twice | 5s | 115-117 |
46 | 90° ~ 0° ~ 90° | Slow waving twice | 11s | 118-119 |
47 | 75° ~ 0° ~ 75° | Slow waving twice | 10s | 120-122 |
48 | 60° ~ 0° ~ 60° | Slow waving twice | 8s | 123-124 |
49 | 45° ~ 0° ~ 45° | Slow waving twice | 6s | 125-127 |
50 | 30° ~ 0° ~ 30° | Slow waving twice | 5s | 128-130 |
51 | (-90°)~ 0° ~ (-90°) | Medium waving 5 times | 7s | 131-132 |
52 | (-75°)~ 0° ~ (-75°) | Medium waving 5 times | 6s | 133-135 |
53 | (-60°)~ 0° ~ (-60°) | Medium waving 5 times | 5s | 136-137 |
54 | (-45°)~ 0° ~ (-45°) | Medium waving 5 times | 4s | 138-140 |
55 | (-30°)~ 0° ~ (-30°) | Medium waving 5 times | 3s | 141-142 |
56 | 90° ~ 0° ~ 90° | Medium waving 5 times | 7s | 143-145 |
57 | 75° ~ 0° ~ 75° | Medium waving 5 times | 6s | 146-147 |
58 | 60° ~ 0° ~ 60° | Medium waving 5 times | 5s | 148-150 |
59 | 45° ~ 0° ~ 45° | Medium waving 5 times | 4s | 151-152 |
60 | 30° ~ 0° ~ 30° | Medium waving 5 times | 3s | 153-155 |
61 | 90° ~ 45° ~ 90° | Slow waving 3 times | 10s | 156-158 |
62 | 90° ~ 30°~ 90° | Slow waving 3 times | 13s | 159-160 |
63 | (-90°) ~ (-45°) ~ (-90°) | Slow waving 3 times | 10s | 161-163 |
64 | (-90°) ~ (-30°) ~ (-90°) | Slow waving 3 times | 12s | 164-165 |
65 | (-90°) ~ 0° | Slow waving gradually decreases angle | 18s | 166-168 |
66 | 90° ~ 0° | Slow waving gradually decreases angle | 18s | 169-170 |
67 | (-90°) ~ 90° | Slow waving gradually decreases angle | 41s | 171-173 |
68 | 0° ~ (-90°) | Slow waving once | 5s | 174-175 |
69 | (-90°) ~ 0° | Slow waving once | 5s | 176-178 |
70 | 0° ~ 90° | Slow waving once | 5s | 179-180 |
71 | 90° ~ 0° | Slow waving once | 5s | 181-183 |
72 | 0° | Fixed angle firing | 12s | 184-185 |
DMX control example 1: firing sequence No. 42
- Set output nozzle straight up
CH1 = 128, CH2 = 0, CH3 = 0, CH4 = 0, CH5 = 0, CH6 = 128 - Set preset Sequence No. 42
CH1 = 128, CH2 = 0, CH3 = 0, CH4 = 0, CH5 = 108, CH6 = 128 - Firing
CH1 = 128, CH2 = 0, CH3 = 255, CH4 = 0, CH5 = 108, CH6 = 128
DMX control example 2: firing sequence No. 8, firing time 10s
- Set output nozzle straight up
CH1 = 0, CH2 = 0, CH3 = 0, CH4 = 0, CH5 = 0, CH6 = 128 - Set preset Sequence No. 8
CH1 = 0, CH2 = 0, CH3 = 0, CH4 = 0, CH5 = 21, CH6 = 128 - Firing, default firing duration is 60s
CH1 = 0, CH2 = 0, CH3 = 255, CH4 = 0, CH5 = 21, CH6 = 128 Keep 10s. - Firing OFF
CH1 = 0, CH2 = 0, CH3 = 0, CH4 = 0, CH5 = 21, CH6 = 128
Wireless Control Mode
When use remote controller, please disconnect DMX cable connection, set machine to Wireless 2.4G to ON status. Match machine with remote controller by Press “A” on remote controller when machine at Wireless Control interface.
- A: OFF / SET, Firing OFF, SET means match machine with remote controller.
- B: Firing, vertical up (0°)
- C: Firing, according to the sequence setting on machine
- D: Clear Material 3s.
- Please replace the battery when the indicator light on remote controller is weak. Battery mode: 9V stacked battery.
- Remote controller for SPARKULAR waverFALL is optional accessory.
SHOWVEN HOST CONTROLLER ZK6200/6300 control:
When use our host controller control SPARKULAR® waverFALL please press “F3” and switch the device on HOST CONTROLLER to CIRCLE FLAMER-6CH. Due to host controller with bi-directional communication with SPARKULAR® waverFALL, for each unit of machine please do allocate a unique DMX address as below:
SPARKULAR No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 |
DMX Address | 1 | 7 | 13 | 19 | 25 | 31 | 37 | 43 | 49 | 55 | 61 | 67 | 73 | 79 | 85 | 91 | 97 | 103 |
Operation Guide
- Install SPARKULAR® waverFALL
- SPARKULAR® waverFALL suggest to be hanged horizontally.
- Make sure the machine is securely installed to avoid falling, make sure to install extra safety rope for each machine.
- Check carefully the output nozzle of each machine, make sure the output nozzle is in good shape and there is no powder aggregate.
- Fill SPARKULAR® waverFALL
- Open powder bags and fill the feeding hopper.
- Choose correct consumable according to the hanging height and safety distance.. SPARKULAR® waverFALL can only use HC8200 LARGE / LARGE I / LARGE II.
HC8200 | Effect length (Low Output) | Effect length (High Output) |
LARGE | 3m | 4m |
LARGE-Ⅰ | 4m | 5m |
LARGE-Ⅱ | 5m | 7m |
Please be noted that there may sparks or remains fall to the ground. Make sure no flammable material on ground in the safety zone.
Make sure the lid of hopper is locked tight after filling.
SAFETY NOTICE: Accidentally burning of consumable HC8200 in the hopper can only use sands
Connect Power / DMX cable
- Connect a power cable to the POWER IN socket of SPARKULAR® waverFALL. Connect the other end of power cable to the power source. Make sure power supply in consistent with the rated voltage of the equipment, and the socket must well grounded.
- If connect machine in sequence, please connect a power link cable to the POWER OUT of previous machine, connect the other end of the power link cable to POWER IN of the next machine.
- The SPARKULAR® waverFALL power supply cable maximum allowed cascade is 6 units (220V version) / 3pcs (110V version). Do not connect exceed units to a single electrical circuit.
- Power ON all SPARKULAR® waverFALL.
- Assign DMX address for each unit of SPARKULAR® waverFALL. If use SHOWVEN host controller or FXcommander to control the machine please allocate a unique DMX address for each unit of machine.
If use remote controller to control SPARKULAR® waverFALL wirelessly, please set machine to wireless ON status and match machine with remote controller. For DMX cable control please execute below operations (f to h). - Connect a DMX cable to the DMX IN socket of first unit of SPARKULAR® waverFALL, connect the male connector end of DMX cable to your DMX controller (FXcommander, HOST CONTROLLER, light console etc).
- Connect a DMX cable to the DMX OUT of previous machine, and the other end of to the DMX IN of next machine. Connect all devices in series in this way.
- Plug in a DMX terminator into the DMX OUT in last unit of machine to improve signal reliability. Signal amplifier is required for long distance (>200m) DMX signal transmission (SHOWVEN DMX splitter 8 with bidirectional signal transmission, thus can get signal feedback from device).
Activate SPARKULAR® waverFALL by swipe RFID card
- Swipe an RFID card. Read the card as show below. SPARKULAR® waverFALL shows time remain if read successfully. SPARKULAR® waverFALL report E4 when remaining time is less than 10 minutes.
- Please note each RFID card come with 200g package HC8200 can increase single machine 20min working time, the maximum recharge time for SPARKULAR® waverFALL is 30min, when time remain reached 30min, it can’t recharge anymore RFID card.
Programming and Firing
- Programming SPARKULAR® waverFALL, set the firing sequences etc.
- Heating up, it takes few minutes, it varies according to the voltage and environment temperature.
- Make sure the prescribed safety zone of related firing sequences are clear.
- Suggest to clear material for SPARKULAR® waverFALL before firing.
- Firing. In order to prevent overheat in the heating chamber and protect machine, the maximum continuous firing time for SPARKULAR® waverFALL is 60s.
- The operator should always have a clear view of the device, so that he/she can stop the show immediately when there is danger.
- Running preset sequence No.1 to clear material for SPARKULAR® waverFALL after show, clear material will remove the remaining particles from heating chamber.
- NOTE:
If use SHOWVEN HOST CONTROLLER ZK6200/6300 to control the firing, please press “F3” to choose “CIRCLE FLAMER-6CH”, then set the firing sequence, as for preset sequence the firing duration is fixed, so please set firing duration 1s. Please do allocate different DMX address for each unit of SPARKULAR WAVERFALL (6 channels), otherwise it will cause signal interference.
Turn Off and clean up
- Power off SPARKULAR® waverFALL, allow SPARKULAR® waverFALL to cool down.
- Disconnect all POWER and DMX cables.
- Empty the remaining HC8200 in hopper, and store the remaining HC8200 in a dry sealed bottle for next time use. Never touch the output nozzle of SPARKULAR® waverFALL when empty the hopper. DANGER OF GET BURNT!
- Operators can use handheld vacuum cleaner to empty the feeding hopper. Do make sure the machine was cool down when clean it. Do NOT use high-power vacuum cleaners to avoid hot consumables being sucked into the vacuum cleaner from the heating chamber and cause fire.
- Clean the surroundings to remove powder residues.
Maintenance
- Empty the feeding hopper before shipment of machine.
- Empty the feeding hopper if long time not use, for high humidity environment we suggest to empty feeding hopper after each show.
- Clear material both before and after the show.
Warranty Instructions
- Sincere thanks for your choosing our products, you will receive quality service from us
- The product warranty period is one year. If there are any quality problems within 7 days after shipping out from our factory, we can exchange a brand new same model machine for you
- We will offer free of charge maintenance service for machines which with hardware malfunction (except for the instrument damage caused by human factors) in warranty period. Please don’t repair machine without factory permission Below situations NOT included in warranty service:
- Damage caused by use other type of consumable which is not originally from SHOWVEN® .
- Damage caused by improper transportation, usage, management, and maintenance, or damage caused by human factors;
- Disassemble, modify or repair products without permission;
- Damage caused by external reasons (lightning strike, power supply etc.)
- Damage caused by improper installation or use;
- For product damage not included in warranty range, we can provide paid service.
- Invoice is necessary when applying for maintenance service from SHOWVEN® .
Showven Technologies Co., Ltd.
Tel: +86-731-83833068
Web: www.showven.cn E-mail: info@showven.cn
Add: No.1 Tengda Road, Liuyang Economic & Technical Development Zone, Changsha, Hunan, 410300, P.R.China
Documents / Resources
![]() |
SHOWVEN SPARKULAR Waver Fall [pdf] User Manual HC8200 Type, LARGE I, LARGE II, SPARKULAR Waver Fall, SPARKULAR, Waver Fall, Fall |