SHOWVEN DMX Relay R12 Allows SFX Technicians
Thanks for choosing SHOWVEN DMX Relay R12, we wish it will bring you lots of exciting moments.
Please read the following manual carefully before operating this product.
Safety Instructions
- The device must be grounded, when replacing the fuse, always replace with the same type.
- Do not allow any flammable materials, water or metal objects enter the machine.
- Please keep the device dry.
- For professional use only, and keep away from children.
- Do not expose to water and/or high humidity. Use between -10 to 50
- There are no user serviceable parts inside this unit. Do not attempt any repairs yourself.
Description
The DMX Relay R12 allows sfx technicians to add DMX control to any switchable device which not include onboard DMX such as CO2 jet, confetti blasters etc. It can convert the DMX signal from the master console into a voltage signal for output. DMX Relay R12 maximum support 12units of switchable devices.
Technical Specifications
- DIMENSION: 485330130mm
- WEIGHT: 7kg
- MAX. OUTPUT POWER: 3800W
- HOUSING MATERIAL: 304 stainless steel
- INPUT VOLTAGE: AC100-240V, 50/60Hz
- VOLTAGE OUTPUT: AC100-240V, 50/60Hz
- VOLTAGE OUTPUT INTERFACE: 12
- MAX. OUPUT CURRENT/OUTPUT: 10A
- CONTROL: DMX
- POWER INPUT CONNECTOR: Neutrik NAC3PX-TOP
- VOLTAGE OUTPUT CONNECTOR: Neutrik NAC3FPX-TOP * 12
Structure
- Voltage output interface (12)
- Output indicator light (12)
- LCD operational panel
- Label
- E-Stop button
- Power IN
- 3-PIN DMX
- Self-resetting main fuse
- 10A fuse (12)
Installation hole diagram
Display and setting
- Control button area:
MENU: Press to switch through menu, press and hold for 3s enter advanced menu
+ : Parameter up
– : Parameter down
ENTER: Confirm and save parameters
NOTE: Screen will switch to main interface automatically if not press any button in about 15s. - Welcome interface:
Display product model and software version.
- Main interface:
First Line: DMX address
Second Line: DMX channel mode 12CH - Main Menu:
Press “MENU” enter main menu interface and switch through different items
NOTE: DMX address and Safety Address can’t overlap.Options Range Default Explanation DMX Address 1-499 1 Set DMX Address DMX Channel Mode 12CH / 12CH-P 12CH-P DMX channel mode Safety Address
13-512
13
Individual safety address setting, when DMX channel mode is 12CH, this item is hidden
Language English English Language switch - DMX Control:
DMX Relay R12 with 2 different channel mode: 12CH-P and 12CH.
12CH-P:
In this channel mode DMX Relay R12 occupies 12 functional channels CH1 to CH12 and 1 separate safety channel CH-S (this channel is independent from operational channel, can be shared with other device).Channel Function Value CH1 OUTPUT 1 ON/OFF control 0~99: OFF
100~255: ON
CH2 OUTPUT 2 ON/OFF control CH3 OUTPUT 3 ON/OFF control CH4 OUTPUT 4 ON/OFF control CH5 OUTPUT 5 ON/OFF control CH6 OUTPUT 6 ON/OFF control CH7 OUTPUT 7 ON/OFF control CH8 OUTPUT 8 ON/OFF control CH9 OUTPUT 9 ON/OFF control CH10 OUTPUT 10 ON/OFF control CH11 OUTPUT 11 ON/OFF control CH12 OUTPUT 12 ON/OFF control CH-S Output enable / disable 0~49 and 201~255: disable output 50~200: enable output 12CH:
In this channel mode DMX Relay R12 occupies 12 functional channels CH1 to CH12.Channel Function Value CH1 OUTPUT 1 ON/OFF control 0~99: OFF
100~255: ON
CH2 OUTPUT 2 ON/OFF control CH3 OUTPUT 3 ON/OFF control CH4 OUTPUT 4 ON/OFF control CH5 OUTPUT 5 ON/OFF control CH6 OUTPUT 6 ON/OFF control CH7 OUTPUT 7 ON/OFF control CH8 OUTPUT 8 ON/OFF control CH9 OUTPUT 9 ON/OFF control CH10 OUTPUT 10 ON/OFF control CH11 OUTPUT 11 ON/OFF control CH12 OUTPUT 12 ON/OFF control
Warranty Instructions
- Sincere thanks for your choosing our products, you will receive quality service from us
- The product warranty period is one year. If there are any quality problems within 7 days after shipping out from our factory, we can exchange a brand new same model machine for you
- We will offer free of charge maintenance service for machines which with hardware malfunction (except for the instrument damage caused by human factors) in warranty period. Please don’t repair machine without factory permission
Below situations NOT included in warranty service:
- Damage caused by improper transportation, usage, management, and maintenance, or damage caused by human factors;
- Disassemble, modify or repair products without permission;
- Damage caused by external reasons (lightning strike, power supply etc.)
- Damage caused by improper installation or use;
For product damage not included in the warranty range, we can provide paid service.
Invoice is necessary when applying for maintenance service from SHOWVEN®.
CONTACT
Showven Technologies Co., Ltd.
Tel: +86-731-83833068
Web: www.showven.cn E-mail: info@showven.cn
Add: No.1 Tengda Road, Liuyang Economic & Technical Development Zone, Changsha, Hunan, 410300, P.R.China
Documents / Resources
![]() |