SHO FPC-1808-II-MB ScanLogic Programming Basic Security Lock
Product Information
Specifications
- Security Levels: Security Level 1 = Fingerprint or code, Security Level 2 = Fingerprint and code
- Manager Code: Default 123456
- Reset Code: Default 999999
- Fingerprint Capacity: Manager – Up to 5, User1 & User2 – Up to 5 each
- Battery Type: Duracell or Energizer
Open lock
- Enter default Manager code 123456
Change Code
- Enter 000000
- Enter existing code, 1 beep
- Enter new 6 digit code, 1 beep
- Repeat new 6 digit code, 2 beeps
* Manager code of 123456 must be changed before any other Users can be added; Manager code cannot be changed back to 123456
**Reset Code must be changed from default
***1 long beep means code is not allowed
Add Manager fingerprint(s)
- Open with Manager code/fingerprint
- Hold “+,” and hold until 2 beeps
- Place fingerprint 4X, 1 beep each
- 2 beeps confirms fingerprint addition
* Manager can add up to 5 fingerprints
Add User1 Code
- Open with Manager code/fingerprint
- Hold “1,” 1 beep
- Enter new 6 digit code, 1 beep
- Repeat new 6 digit code, 2 beeps
Add User2 Code
- Open with User1 code/fingerprint
- Hold “1,” 1 beep
- Enter new 6 digit code, 1 beep
- Repeat new 6 digit code, 2 beeps
Add fingerprints - Open with own code/fingerprint
- Hold “+,” 1 beep
- Place fingerprint 4X, 1 beep each
- 2 beeps confirms fingerprint addition
* User1 and User2 can add up to 5 fingerprints
Delete own fingerprints (All)
- Open with your own code/fingerprint
- Hold “-”, 2 beeps
Delete User2 (Code & fingerprints)
- Open with User1 code/fingerprint
- Hold “3”, 2 beeps
* User2 code and fingerprints are deleted
Delete All (Codes/fingerprints)
- Open with manager code/fingerprint
- Hold “3”, 2 beeps
* Manager code remains unchanged, User1 and User2 are deleted
Reset (resets codes to factory default)
- Input reset code, default is 999999
- Hold “6”, 2 beeps
* Lock is in default mode, Manager code reverts to 123456, Reset code remains unchanged
Turn beeper off
- Open with Manager or User1 code/fingerprint
- Hold “4,” 1 beep
Turn beeper on
- Open with Manager or User1 code/fingerprint
- Hold “4,” 2 beeps
Security Levels
- Security Level 1 = Fingerprint or code
- Security Level 2 = Fingerprint and code
Change to Security Level 2 (fingerprint and code)
- Open with Manager or User1 code/fingerprint
- Hold “5,” 1 beep, then 2 beeps
Change to Security Level 1 (fingerprint or code)
- Open with Manager or User1 code and fingerprint
*All of your fingerprints have been deleted - Hold “5,” 1 beep, then 1 beep
Penalty Time
- The entry of 5 incorrect codes will cause the lock to enter Penalty Time where the lock is lock down for a period of 5 minutes. You cannot open the lock during the penalty time period.
- During the Penalty Time, the keypad will beep every 5 seconds and the buttons on the keypad are not operable. Entering additional codes during penalty time does not extend penalty time.
- Two beeps indicates penalty time has expired and the beeping will stop, enter a valid code to open the safe lock.
- Note: If after penalty expires you enter an invalid code two more times, the lock will go back into penalty time.
Troubleshooting
- Lock beeps 10 times after fingerprint/code entry: This is the low battery indicator. Replace the battery with a new Duracell or Energizer battery.
- Green lights after input of fingerprint or code – this is an indication of a valid fingerprint or code entry
- Red lights after input of fingerprint or code – this is an indication of an invalid fingerprint or code entry
We have assigned a new reset code and kept that on file See attached document retention policy if you would like us to destroy those records for maximum privacy.
FAQ
Q: What should I do if the lock beeps 10 times after fingerprint/code entry?
A: The beeping indicates a low battery. Replace the battery with a new Duracell or Energizer battery.
Documents / Resources
![]() |
SHO FPC-1808-II-MB ScanLogic Programming Basic Security Lock [pdf] Instructions FPC-1808-II-MB ScanLogic Programming Basic Security Lock, FPC-1808-II-MB, ScanLogic Programming Basic Security Lock, Programming Basic Security Lock, Basic Security Lock, Security Lock |