SECURITY BRANDS logo

QUICK START GUIDE

SECURITY BRANDS logo 2

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System

Model 27-210, 27-21

  1. Unpack the box and make sure you have all items shown here. (Screwdriver not shown.)
    SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - box 1
  2. Unlock and open the front panel of the unit for mounting, wiring, and setup.
    SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - box 2
  3. Mount unit to pedestal using included mounting hardware.
    (This step may be completed later.)
    SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - box 3

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - warning WARNING SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - warning

AUTOMATIC GATES CAN CAUSE SERIOUS INJURY OR DEATH!

ALWAYS CHECK THAT THE GATE PATH IS CLEAR BEFORE OPERATING!

REVERSING OR OTHER SAFETY DEVICES SHOULD ALWAYS BE USED!

MONSTER MNICON Portable Waterproof Bluetooth Speaker - warning 4 CAUTION MONSTER MNICON Portable Waterproof Bluetooth Speaker - warning 4

Use all four carriage bolts when mounting the unit to a pedestal.
Leave the antenna in place.
Seal all openings created in the enclosure.
Failure to follow these instructions can damage the unit and/or cause it not to function correctly!

What’s what?
All important components labeled
Model 27-210 is shown

The unit is shown with the front panel open.
Wiring/cabling not shown for clarity

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - What’s what

4. Connect wires.
Feed wires through the back of the unit, and connect as shown using included screwdriver.
Excessive force can damage the unit!

Additional wiring diagrams can be found on Pages 5 and 6.

MONSTER MNICON Portable Waterproof Bluetooth Speaker - warning 4 CAUTION MONSTER MNICON Portable Waterproof Bluetooth Speaker - warning 4

If the included 12-V AC/DC adapter will not be used, please go to Page 4 and follow the procedure, Using a Third-Party Power Source.
Do not exceed 24 VAC/DC! Failure to choose a compatible power source can damage the unit!

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Connect wires

Using a Third-Party Power Source (Optional)

IMPORTANT
If you would like to use a third-party
power source such as solar, verify that it
conforms to the following specs:
Input
12–24 VAC/DC no more than 10% beyond this rangeCurrent Draw
less than 111 mA @ 12 VDC
less than 60 mA @ 24 VDC

4a Connect wires to the unit as shown in Step 4.
4b Connect wires to your power source, making sure you connect positive to positive and negative to negative.

MONSTER MNICON Portable Waterproof Bluetooth Speaker - warning 4 CAUTION MONSTER MNICON Portable Waterproof Bluetooth Speaker - warning 4
Double-check that you have wired from positive on the Edge unit to positive on your power source and negative on the Edge unit to negative on your power source.
Reverse polarity can damage the unit!

5. The close front panel of the unit and lock it.

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - front panel o

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - warning STOP SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - warning
Before going forward, double-check all wiring and make sure the unit has power!
Wiring diagrams for connecting to accessory devices can be found on Pages 5 and 6.
For connecting accessories not mentioned, please contact Technical Support.
Make sure the gate or door path is clear before completing Step 7!

6. Add Access Code to Relay A.
(To add multiple codes, enter each of them before pressing the pound key.)

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Access Code

NOTE: The green arrow indicates a “good” tone on the Edge unit. By default, the following codes are reserved and cannot be used: 1251, 1273, 1366, 1381, 1387, 1678, 1752, and 1985.

7. Make sure the gate or door path is clear; then enter the access code on the keypad, and the confirm gate or door opens.
SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - COMPLETE INSTALLATION COMPLETE!

Jump to Page 7 to continue programming and download the Edge Smart Keypad app.

A Event Inputs
Wiring for accessories such as a request-to-exit device

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Event Inputs

B Digital Inputs
Wiring to various accessories

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Digital Inputs

C Wiegand Device
Wiring for a Wiegand device

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Wiegand Device

If mounting a Wiegand card reader to the Edge unit front panel, remove the existing cover plate and hex nuts to reveal the mounting holes and wiring passthrough hole.

MONSTER MNICON Portable Waterproof Bluetooth Speaker - warning 4 CAUTION MONSTER MNICON Portable Waterproof Bluetooth Speaker - warning 4
Disconnect power to the Edge unit before connecting Wiegand devices.
Failure to disconnect power can damage the unit!

Downloading the Edge Smart Keypad App for iOS/Android

Lebooo LBC 0001A Smart Sonic Toothbrush - sembly 2 The Edge Smart Keypad app is for ADMINISTRATOR USE ONLY and is not intended for users.

a Grab your smartphone or tablet. (These steps are optional. The unit can be fully programmed from the keypad.)

b Navigate to your app store, and search for “edge smart keypad.”

c Find the Edge Smart Keypad app by Security Brands, Inc. and download it.

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Edge Smart KeypadEdge Smart Keypad
Security Brands, Inc.

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - help NEED HELP SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - help

You can find plenty of useful resources online to help you get your new Edge unit up and running quickly and easily.
Go to securitybrandsinc.com/edge/
If you need further assistance, please call
Technical Support at 972-474-6390.

D Pairing Edge Unit

Connect your mobile device to your Edge unit for use with the app.
The app is available for administrators who want to use it. Nearly all functionality is available through direct programming via the keypad.

IMPORTANT ICON IMPORTANT! Make sure your Edge unit is powered on and that Bluetooth is enabled on your mobile device or pairing will not work.

Step 1 – Grab your mobile device and open the Edge Smart Keypad app.
If you do not have the app, follow the steps on this page for downloading it.

Step 2 – Fill out your account information and tap the “Sign Up” button.
If you have already created an account, you will log in instead.

Step 3 – On the Paired Keypads screen, tap the “Add Keypad” button.

Step 4 – On the Add Keypad screen, tap the Edge unit you want to pair.
If you do not see any Edge units listed, make sure your Edge unit is powered on and is in Bluetooth range.

Step 5 – Complete the procedure shown on your mobile device. These steps will be completed using the PIN pad on your Edge unit. Step 6 – Enter the Master Code (default is 1251) on your mobile device.

Step 7 – Enter the code shown on your mobile device at the Edge unit. This step must be completed within the time duration displayed.

Step 8 – Change your Master Code if you like.
This step is recommended, but optional, and can be done at a later time.

Your new Edge unit is now be paired and will appear on the Paired Keypads screen. Tapping on the Edge unit on this screen will give you access to relay control and full access control management of the Edge unit from within the app.

Lebooo LBC 0001A Smart Sonic Toothbrush - sembly 3 For more information and guidance, please go to securitybrandsinc.com/edge/ or call Technical Support at 972-474-6390 for assistance.

E1 Direct Programming / Unit Configuration

Change Master Code
(Highly recommended for security purposes)

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Change Master Code

Change Sleep Code

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Change Sleep Code

The green arrow indicates a “good” tone on the unit.
Always wait for a good tone before moving on.

By default, these codes are unavailable for use: 1251, 1273, 1366, 1381, 1387, 1678, 1752, 1985.

Lebooo LBC 0001A Smart Sonic Toothbrush - sembly 3 FIND MORE Lebooo LBC 0001A Smart Sonic Toothbrush - sembly 3

For all programming not shown here, as well as reset procedures and the Edge
Smart Keypad app user guide, please visit our Edge start page:
securitybrandsinc.com/edge/

Programming Sub Modes

  1. Add Access Code(s) to Relay A
  2. Delete Code (Non-Wiegand)
  3. Change Master Code
  4.  – 3 Add Latch Code to Relay B
    4 – 4 Change Sleep Code
    4 – 5 Change Code Length (Non-Wiegand)
    4 – 6 Change Relay Trigger Time
    4 – 7 Enable/Disable Timers and Schedules
    4 – 8 Enable/Disable “3 Strikes, You’re Out”
    4 – 9 Configure Event Input 1
  5.  Add Latch Code to Relay A
  6. Configure Wiegand Inputs
  7.  Add Access Code(s) to Relay B
  8.  Add Limited-Use Code
  9. Delete All Codes and Timers

Things to Know

The Star Key (*)
If a mistake is made, pressing the star key deletes your entry. Two beeps will sound.

The Pound Key (#)
The pound key is good for one thing and one thing only: exiting the programming mode.

E2 Direct Programming / Unit Configuration

The green arrow indicates a “good” tone on the unit. Always wait for a good tone before moving on.

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Direct Programming

E3 Direct Programming / Unit Configuration

Toggle Silent Mode
(Toggles Silent Mode, which mutes all audible-tone feedback on the unit)

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Toggle Silent Mode

Configure Event Input 1
(Allows an external device to affect keypad operation or trigger a relay. To configure additional inputs, use the Edge Smart Keypad app.)

Mode 1 – Remote Open Mode
Triggers either Relay A or Relay B when event input state changes from normally open (N/O) to normally closed (N/C).

Mode 2 – Log Mode
Makes log entry of event input state when event input state changes from normally open (N/O) to normally closed (N/C).

Mode 3 – Remote Open and Log Mode
Combines Modes 1 and 2.

Mode 4 – Arming Circuit Mode
Enables either Relay A or Relay B when event input state changes from normally open (N/O) to normally closed (N/C). Otherwise, the selected relay is disabled.

Mode 5 – Remote Operation Mode
Triggers or latches either Relay A or Relay B when event input state changes from normally closed (N/C) to normally open (N/O).

Mode 0 – Event Input 1 Disabled

Modes 1, 3, and 4

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Modes 1, 3, and 4

E4 Direct Programming / Unit Configuration

Configure Event Input 1 (continued)
(Allows an external device to affect keypad operation or trigger a relay. To configure additional inputs, use the Edge Smart Keypad app.)

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Input 1

E5 Direct Programming / Unit Configuration

Configure Wiegand Input
(Allows enabling or disabling of a Wiegand input and configuration of the Wiegand device type. For the tag reader type, use the Edge Smart Keypad app.)

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Configure Wiegand Input

Change Default Facility Code

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Change Default Facility Code

F1 Direct Programming / Onboard Keypad

Add Access Code(s) to Relay B
(To add multiple codes, enter each of them before pressing the pound key)

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Add Access Code

F2 Direct Programming / Onboard Keypad

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Programming

G1 Direct Programming / External Wiegand Keypad

Add Wiegand Keypad Access Code(s)
(Uses default facility code; to add multiple codes, enter each of them before pressing pound key)

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Add Wiegand Keypad Access Code

G2 Direct Programming / External Wiegand Keypad

Add Wiegand Keypad Latch Code(s)
(Uses default facility code; to add multiple codes, enter each of them before pressing pound key)

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System - Add Wiegand Keypad Latch Code

SECURITY BRANDS 27 210 EDGE E1 Smart Keypad with Intercom Access Control System

SECURITY BRANDS logo 3

NEED HELP

Call 972-474-6390
Email techsupport@securitybrandsinc.com
We are available Mon–Fri / 8 am–5 pm Central

© 2021 Security Brands, Inc. All rights reserved

Documents / Resources

SECURITY BRANDS 27-210 EDGE E1 Smart Keypad with Intercom Access Control System [pdf] User Guide
27-210, 27-215, EDGE E1 Smart Keypad with Intercom Access Control System

References

Leave a comment

Your email address will not be published. Required fields are marked *