Secop SC15G Compressor
Specifications
- Model: SC15G
- Compressor: 208-230V/60Hz 1~
- Sales Code: 104G8526
- Refrigerant: R134a
- Motor Configuration: CSIR
- Voltage Range: 187-254V
- Approvals: VDE, UL, KC
Instruction
Single Packs
| Position | Title | Code | Amount |
| 1 | Compressor SC15G | 104G8526 | 1 |
| 2 | Starting relay | 117U6011 | 1 |
| 3 | Starting capacitor (80µF 220V, 6.3mm) | 117U5017 | 1 |
| 4 | Cord relief | 103N1004 | 1 |
| 5 | Cover | 103N2008 | 1 |
| 6 | Bolt joint for one compressor | M6 | ø16mm | 118-1917 | 1 |
- Secop GmbH
- Lise-Meitner-Straße 29
- 24941 Flensburg, Germany
- Tel: +49 461 4941 0
- www.secop.com
- Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary to specifications already agreed. All trademarks in this material are the property of the respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved. Single Pack SC15G 208-230V 60Hz CSIR Single pack code number: 195B4488
| Compressor design | |||
| Oil type | Polyolester | Refrigerant(s) | R1 a |
| Oil viscosity | 22cST | Displacement | 15,28cm3 / 0,93cu.in |
| Oil quantity | 500cm3 / 16,9fl.oz | Compressors on pallet | 80 |
| Refr. charge – tech. limit | 1300g / 45,9oz | ||
| Free gas volume comp. | 1410cm3 / 47,7fl.oz | ||
| Weight | 13,2kg / 29,1lbs | ||
| Motor protection | 1# internal | ||
| Winding resistance main | 4,4Ω (at 25°C) | ||
| Winding resistance aux | 14Ω (at 25°C) | ||
| Max. winding temp. | 125°C / 257°F | ||
| Max. discharge temp. | 135°C / 275°F | ||
General – Configurations with SC15G
Conf. 1
- Motorconfiguration CSIR
- Power supply (nominal) 208-230V/60Hz Number of phases 1
- Voltage range 187-254V
- Approvals VDE, UL, KC
- Starting torque HST
- Note – / –
Applications with SC15G
Conf. 1
- Refrigerant R134a
- Application MBP
- System cooling fan 3m/s
- Hot gas defrost OK
- Long interval pull down OK
Electrical data – Configurations with SC15G
Conf. 1
- Starting device type relay
- Run capacitor -/-
- Start capacitor 80µF LRA (locked rotor amps / 4s)
- RLA (rated load amps / 1s) -/-A Cut in current
Compressor dimensions
Mousing A Height 209mm / 8,23in
B Height 203mm / 7,99in
C Length shell 218mm / 8,58in
D Length w. cover 255mm / 10,04in
E Width 151mm / 5,94in
|
|
|||||||||
| Connectors | Suction | Discharge | Process | ||||||
| X | y | z | |||||||
| Diameter | [mm] | 0i 10,11-10,29 | 0i 6,41-6,59 | 0i 6,41-6,59 | |||||
| (i inside, o outside) | [in] | 0i 0,4-0,41 | 0i 0,25-0,26 | 0i 0,25-0,26 | |||||
| Material | copper | copper | copper | ||||||
| Horizontal angle | 2° | 37° | 37° | 143° | |||||
| Vertical angle | 2° | 30° | 0° | 150° | |||||
| Position l/h/w | [mm] | 107/183/55 | 115/100/63 | -107/183/55 | |||||
| [in] | 4,2/7,2/2,2 | 4,5/3,9/2,5 | -4,2/7,2/2,2 | ||||||
| Straight tube l. | [mm]
[in] |
12
0,5 |
12
0,5 |
12
0,5 |
|||||

Compressor fixation

Application notes
- Provision for PE Grounding is located at the PE Stamp on the compressor
- LRA value on compressor label and datasheet may differ due to different test conditions for UL approval.
Configuration
- Motor configuration CSIR
- Power supply (nominal) 208-230V/60Hz 1~ Refrigerant
- Application MBP
- Voltage range 187-254V
- Starting torque HST
- Approvals VDE UL KC
Ambient machine room temperatures minimum maximum
- Ambient temperature range: 10 – 43°C / 50 – 110°F
- Machine room temperature range: 10 – 48°C / 50 – 119°F
- Compressor cooling: fan 3m/s
Operation Limits
Operation pressure range

Electrical accessories wiring diagram

Components
- a2 relay 117U6011
- start capacitor (80uF) 117U5017
- d cord relief 103N1004
- b plastic cover 103N2008
Optimization + standard conditions

SC Compressors

SC Compressors Service/Repair – R290 
Installation
- Ensure the power supply matches the nominal requirements of 208-230V/60Hz.
- Connect the compressor according to the provided wiring diagram.
- Ensure proper grounding as indicated on the compressor.
Maintenance
- Check oil level periodically and top up as needed.
- Inspect connectors and fixations for any signs of damage.
- Keep the compressor cooling fan free from obstructions for optimal performance.
Troubleshooting
- If the compressor fails to start or experiences abnormal noises, consult a qualified technician for assistance.
Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already on order
provided that such alterations can be made without subsequential changes being necessary to speci¿cations already agreed. All trademarks in this material are the property of the respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved. www.secop.com
FAQs
What should I do if the compressor does not start?
How often should the oil level be checked?
Can I use a different refrigerant with this compressor?
Documents / Resources
![]() | SC15G Compressor |
References
- 93cu.in93cu.in
- Advanced Compressors Technology & Sustainable Cooling Solutions | Secopwww.secop.com
- Soluciones Secop para refrigeración comercial | Secopwww.secop.com
- User Manualmanual.tools