Product Specifications

  • Model Designation: HTK70AA
  • Compressor: 220-240V/50Hz 1~
  • Sales Code: 16125300
  • Refrigerant(s): R600a
  • Displacement: –
  • Compressors on Pallet: –

Components in Single Pack HTK70AA 220-240V 50Hz RSIR

  • Title: Compressor HTK70AA
  • Code: 16125300
  • Amount: 1

Instructions

Single Packs

Single Pack HTK70AA 220-240V 50Hz RSIR
Single pack code number: 195B4530

Position Title Code Amount
1 Compressor HTK70AA 16125300 1
2 Clip 10633900 4
3 Steel pin 10634100 4
4 Washer 10634300 4
5 Screw for cable clamp 10636000 1
6 Screw for cable clamp 10636200 1
7 Cover 10636401 1
8 Earth screw 10641201 1
9 Rubber grommet 16mm 11322600 4
10 Cable clamp 11341000 1
11 Terminal board 4.8mm 15163800 1
  • Secop GmbH
    • Lise-Meitner-Straße 29
    • 24941 Flensburg, Germany
    • Tel: +49 461 4941 0
    • www.secop.com
  • Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary to specifications already agreed. All trademarks in this material are the property of the respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved.
Compressor design
Oil type Mineral Refrigerant(s) R  a
Oil viscosity 5cST Oisplacement 6,6cm3 / 0,4cu.in
Oil quantity 162cm3 / 5,5fl.oz Compressors on pallet 100
Refr. charge – tech. limit 150g / 5,3oz
Free gas volume comp. 1500cm3 / 50,7fl.oz
Weight 7,9kg / 17,4lbs
Motor protection external
Winding resistance main 34Ω (at 25°C)
Winding resistance aux 15,5Ω (at 25°C)
Max. winding temp. 130°C / 266°F
Max. discharge temp. 130°C / 266°F

General – Configurations with HTK7 AA

Conf. Conf.
Motorconfiguration RSIR RSCR
Power supply (nominal) 220-240V/50Hz 220-240V/50Hz
Number of phases 1 1
Voltage range 187-264V 187-264V
Approvals VOE VOE
Starting torque LST LST
Applications with HTK7 AA
Conf. Conf.
Refrigerant R600a R600a
Application LBP LBP
System cooling static static
Hot gas defrost -/- -/-
Long interval pull down -/- -/-

Electrical data – Configurations with HTK7 AA

Conf. Conf.
Starting device type PTC PTC
Run capacitor -/- 3/4µF
Start capacitor -/- -/-
LRA (locked rotor amps / 4s/ U(N))
RLA (rated load amps / 1s/ U(N)) -/-A -/-A
Cut in current (U(N))

Compressor dimensions

Housing                             A Height                             166mm / 6,54in

B Height                             159mm / 6,26in

C Length shell                   194mm / 7,64in O Length w. cover             238mm / 9,37in E Width                              151mm / 5,94in

Connectors Suction

X

Discharge

Y

Process

z

Oiameter [mm] 0i 6,1-6,2 0i 5,1-5,2 0o 5,92-6,08
(i inside, o outside) [in] 0i 0,24-0,24 0i 0,2-0,2 0o 0,23-0,24
Material Horizontal angle  

 

2°

copper 45° copper 13° copper 0°
Vertical angle  2° 30° 40° 145°
Position l/h/w           [mm] [in]

Straight tube l.          [mm] [in]

120/72/62

4,7/2,8/2,4

14

0,5

112/106/62

4,4/4,2/2,4

14

0,5

-140/136/70

-5,5/5,4/2,8 75

3

Secop-HTK70AA-Compressor-Data-Sheet-fig1

Compressor fixation

Secop-HTK70AA-Compressor-Data-Sheet-fig3

  • Mounting accessories                                                                      order code
  • 4ZN with rubber grommet                                                              772N
  • 4ZN with rubber grommet and sleeve for M6                              768N
  • Bolt joint kit                                                                                      4ZN + 118-1917 (18)
  • 4ZN with Snap on kit                                                                     776NSecop-HTK70AA-Compressor-Data-Sheet-fig4

Application notes

  • Provision for PE Grounding is located at the PE Stamp on the compressor
  • Housing with dip-tray fixture (omega bracket).
  • Various options of connectors are possible – please contact SECOP-Sales.

Configuration

  • Motorconfiguration RSIR
  • Power supply (nominal) 220-240V/50Hz 1 ~
  • Refrigerant R600a
  • Application LBP
  • Voltage range 187-264V
  • Starting torque LST
  • Approvals VDE

Ambient/ machine room temperatures minimum/maximum

  • Ambient temperature range: 10 – 43°C / 50 – 110°F
  • Machine room temperature range: 10 – 48°C / 50 – 119°F
  • Compressor cooling: static

Operation pressure range

Secop-HTK70AA-Compressor-Data-Sheet-fig6

Electrical accessories / wiring diagram

Secop-HTK70AA-Compressor-Data-Sheet-fig5

Components

  • terminal board (PTC, 4.8mm) 15163800
  • b cover terminal board 10636401
  • cable clamp 11341000
  • screw – uni6954 10636000
  • screw – uni6954 10636200
  • screw uni en iso 4757 10641201

Alternative components

  • terminal board (PTC, 6.3mm) 15162300

Optimization + standard conditions

Secop-HTK70AA-Compressor-Data-Sheet-fig7Secop-HTK70AA-Compressor-Data-Sheet-fig14Secop-HTK70AA-Compressor-Data-Sheet-fig15

Configuration

  • Motorconfiguration RSIR
  • Power supply (nominal) 220-240V/50Hz 1 ~
  • Refrigerant R600a
  • Application LBP
  • Voltage range 187-264V
  • Starting torque LST
  • Approvals VDE

Ambient/ machine room temperatures minimum/maximum

  • Ambient temperature range: 10 – 43°C / 50 – 110°F
  • Machine room temperature range: 10 – 48°C / 50 – 119°F
  • Compressor cooling: static

Operation pressure rangeSecop-HTK70AA-Compressor-Data-Sheet-fig9Electrical accessories / wiring diagram

Secop-HTK70AA-Compressor-Data-Sheet-fig8

Components

  • terminal board (PTC, 4.8mm) 15163800
  • run capacitor (3uF, 4.8mm) 10692902
  • b cover terminal board 10636401
  • cable clamp 11341000
  • screw – uni6954 10636000
  • screw – uni6954 10636200

Alternative components

  • terminal board (PTC, 6.3mm) 15162300
  • run capacitor (4uF, 6.3mm) 15186801

Optimization + standard conditions

Secop-HTK70AA-Compressor-Data-Sheet-fig10Secop-HTK70AA-Compressor-Data-Sheet-fig15 Secop-HTK70AA-Compressor-Data-Sheet-fig16

K-Series Compressors GTK, HKK, HMK, HTK, HXK, HZK

Secop-HTK70AA-Compressor-Data-Sheet-fig11 Secop-HTK70AA-Compressor-Data-Sheet-fig12 Secop-HTK70AA-Compressor-Data-Sheet-fig13

Installation Steps

  1. Clip steel pin (Code: 10633900) into position 2.
  2. Insert washers (Code: 10634100) into positions 3, 4, 5, and 6.
  3. Screw cable clamps (Code: 10636200) into positions 7 and 8.
  4. Attach the cover (Code: 10636401) to position 9.
  5. Secure the earth screw (Code: 10641201) in position 10.
  6. Place the rubber grommet (Code: 11322600) in position 11.
  7. Insert the cable clamp (Code: 11341000) into position 12.
  8. Connect the terminal board (Code: 15163800) with a 4.8mm terminal.

Maintenance

  • Ensure to check and clean the compressor regularly to maintain optimal performance.

Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already on order
provided that such alterations can be made without sub sequential changes being necessary to specifications already agreed. All trademarks in this material are the property of the respective companies. Secop and the Secop logotype are trademarks of Secop GmbH.A ll rights reserved. www.secop.com

FAQs

Can I use a different refrigerant with the HTK70AA compressor?

No, the HTK70AA is designed for use with R600a refrigerant only.

What is the voltage range supported by the HTK70AA compressor?

The compressor supports a voltage range of 187-264V.

How do I ground the compressor properly?

The provision for PE grounding is located at the PE stamp on the compressor housing with a dip-tray fixture (omega bracket).

Documents / Resources

PDF thumbnailHTK70AA Compressor Data Sheet
User Manual · HTK70AA, 16125300, HTK70AA Compressor Data Sheet, HTK70AA, Compressor Data Sheet, Data Sheet, Sheet

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.