BRITELINE
GEN2 1
External version
INSTALLATION INSTRUCTIONS
BRITELINE GEN2 1 Versatile and Efficient Lighting
PRODUCT OVERVIEW
BRITELINE GEN2 1 | EXTERNAL GEAR BOX | ||||||||
A | B | C | ![]() |
D | E | F | G | H | ![]() |
609mm 23.97in |
332mm 13.07in |
436mm 17.16in |
16.5kg 36.371bs |
416mm 16.37in |
372mm 14.64in |
221mm 8.7in |
205mm 8.07in |
121mm 4.76in |
6.2kg 13.6lbs |
EPA – Effective Projected Area
a = 0° | a = 30° | a = 45° | a = 70° | a = 90° | |||||||||||
S(m²) | CxS (m²) |
EPA (ft²) |
S(m²) | CxS (m²) |
EPA (ft²) | S(m²) | CxS (m²) |
EPA (ft²) |
S(m²) | CxS (m²) |
EPA (ft²) | S(m²) | CxS (m²) |
EPA (ft²) |
|
S1 | 0.057 | 0.07 | 0.74 | 0.0951 | 0.12 | 1.23 | 0.1100 | 0.14 | 1.43 | 0.1339 | 0.17 | 1.73 | 0.1406 | 0.17 | 1.82 |
S2 | 0.1406 | 0.17 | 2. | 0.1382 | 0.17 | 1.79 | 0.1258 | 0.16 | 1.63 | 0.0920 | 0.12 | 1.19 | 0.0570 | 0.07 | 0.74 |
S3 | 0.0355 | 0.05 | 0.46 | 0.0355 | 0.05 | 0.46 | 0.0355 | 0.05 | 0.46 | 0.0355 | 0.05 | 0.46 | 0.0355 | 0.05 | 0.46 |
MOUNTING
Screws and washers are not included in the package!
Minimum screw requirement:
Vibration standard | IEC 0.5g / ANSI 1.5g |
Minimum fastener requirement | 1x M20 8.8 or A2-70 DIN9021 large plain washer |
Tightening torques | 1xM20: 200 Nm 2xM20: 140 Nm |
Recommended to use anti-seizing agent (Tikal Tef-Gel®) !
![]() |
1. 1xM20 with extra large washer or 2. 2xM20 with extra large washer |
Mounting dimensions
D1 | D2 | D3 | D4 | D5 |
min 250mm min 9.84in |
70mm 2.75in |
150mm 5.9in |
320mm 12,6in |
460mm 15.98in |
Minimum Surface Contact Area for screw fixation
Fasteners are not included in the package!
Remark: the hatched area always need to be supported by a flat planar mounting surface as minimum.
Wider surface contact is recommended, smaller is not allowed!
ANGLE ADJUSTMENT
- Loosen the clamp screws
- Adjust tilting angle
Separate scale for adjusting the distance of the optical block from the luminaire holderThe swing arm inclination is adjustablein 10 degree increments relative to fork base.
ALLOWED tilt angle is between -10° to 90°
- Tighten the clamp screws
Do not exceed the proposed torque levels, as it may result in fraction of the parts!
ALLOWED POSITIONING
GEAR INSTALLATION
SAFETY CABLE
Steel safety cable should pass through the holes shown in the drawing in sequence.
Then connect the two ends with the lock and tighten the lock screw by hand.
For installations over 3m height: secondary safety system application is mandatory, which is appropriated for the luminaire load (e.g. safety cable)
1500mm/59.05in safety cable is supplied with the luminaire.
ELECTRICAL CONNECTION
- Remove the R-type buckles from the junction box and gear box
- Open junction box and gear box
Cable ID Connection Cable gland Suitable cable Ø A Mains input M20 Ø6-10mm or
Ø10-14mmB Mains re-launch C DC output to optical block M25/cable ptorection
compatibilityØ6-10mm or
Ø10-14mmD Dimming input M16 Ø4.5-7.5mm or
Ø7.5-10.5mmE Dimming re-launch - Cable types and cable gland
When using a larger external diameter cable, the plug and the smaller inner diameter seal need to be removed
When using a smaller external diameter cable, simply remove the plug
- Make electrical connection
Wiring should strictly follow the marking label instruction, otherwise the product could be damaged or the functions could be affected. - Close junction box and gear box
Close the cover of the junction box and gear box, and put the R-type buckles back on both.
RECOMMENDATIONS
- Surrounding distances
At least 1 meter distance should be kept from surrounding walls, floor, and ceiling for all types of mounting/inclination.
- Maximum number of luminaires per MCB
Product Driver MCB B type B10 B13 B16 B20 B25 B32 B40 BRITELINE GEN2 1 ©220V EUM-680MG/BG 1 2 2 3 4 5 6 BRITELINE GEN2 1 ©480V ESM-680MG/BG 2 2 3 4 5 6 7 Product Driver MCB C type C10 13 16 C20 C25 C32 C40 BRITELINE GEN2 1 ©220V EUM-680MG/BG 1 2 3 3 4 5 6 BRITELINE GEN2 1 ©480V ESM-680MG/BG 3 4 5 7 9 11 14
AIMING DEVICE
The small blocks on the side of the optical block assure the installation of the built-in aiming devide.
The external aiming device position 1 needs to be aligned with positions 2 and 3
ACCESSORIES – HOOD
SAFETY INSTRUCTIONS
The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person. Always switch off the power prior to installation, maintenance or repair activities.
RISK GROUP 2 – CAUTION! Hazardous optical radiation may be emitted from this product. Do not stare at the luminaire when operating as it may be harmful to the eyes. The luminaire should be positioned so that prolonged staring at the luminaire at a distance of less than 0.2m is not expected.
This product contains a light source of an energy efficiency class G or higher.
In case of PVC insulated mains cable, the installer MUST ensure that the WHOLE cable is protected against climatic conditions, especially UV rays and rain, by making sure that the cable is contained inside the luminaire and pole Y-connection: In case of damage to the wire, it has to be replaced only by the manufacturer, distributor or by an expert, to avoid risks.
www.schreder.com
Rev B | 07-2023
Documents / Resources
![]() |
Schreder BRITELINE GEN2 1 Versatile and Efficient Lighting [pdf] Instruction Manual BRITELINE GEN2 1 Versatile and Efficient Lighting, BRITELINE GEN2 1, Versatile and Efficient Lighting, Efficient Lighting, Lighting |