Schr der LogoTFLEX COMBI
1-2-3Schr der TFLEX COMBI LED Solution For Tunnel LightingINSTALLATION INSTRUCTIONSSchr der TFLEX COMBI LED Solution For Tunnel Lighting - icon

TFLEX COMBI LED Solution For Tunnel Lighting

Schr der TFLEX COMBI LED Solution For Tunnel Lighting

Product dimensions

TFLEX LENGTH WIDTH HEIGHT (B) WEIGHT
mm in mm in mm in kg lb
COMBI 1 A3 860 34 440 17. 117 5. 16 32.
COMBI 2 A2 1247 49 23 51.
COMBI 3 Al 1635 64 32 71.
COMBI 3 (3G) Al 1635 64 34 75.

COMBI 1 and 2: based on 5mm thickness bracket.
COMBI 3: 5mm thickness bracket plus additional bracket available.

Schr der TFLEX COMBI LED Solution For Tunnel Lighting - Fig

FIXED BRACKETS Ansi3G

Schr der TFLEX COMBI LED Solution For Tunnel Lighting - Fig 1

SUSPENDED SWIVELING FIXATION, PULL OUT

Schr der TFLEX COMBI LED Solution For Tunnel Lighting - Fig 2

SUSPENDED SWIVELING FIXATION, ADJUSTABLE

Schr der TFLEX COMBI LED Solution For Tunnel Lighting - Fig 3

WALL SWIVELING FIXATION, PULL OUT

Schr der TFLEX COMBI LED Solution For Tunnel Lighting - Fig4

WALL SWIVELING FIXATION, ADJUSTABLE

Schr der TFLEX COMBI LED Solution For Tunnel Lighting - Fig 5

HOOK FIXATION

Schr der TFLEX COMBI LED Solution For Tunnel Lighting - Fig 6

QPD CONNECTORS

Schr der TFLEX COMBI LED Solution For Tunnel Lighting - Fig 7

Schr der TFLEX COMBI LED Solution For Tunnel Lighting - Fig 8

SAFETY INSTRUCTIONS

The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person. Always switch off the power prior to installation, maintenance or repair activities.
RISK GROUP 2 – CAUTION! Hazardous optical radiation may be emitted from this product. Do not stare at the luminaire when operating as it may be harmful to the eyes.  he luminaire should be positioned so that prolonged staring at the luminaire at a distance of less than 0.77m is not expected.
This product contains a light source of an energy efficiency class G or higher.
In case of PVC insulated mains cable, the installer MUST ensure that the WHOLE cable is protected against climatic conditions, especially UV rays and rain, by making sure that the cable is contained inside the luminaire and pole Y-connection: In case of damage to the wire, it has to be replaced only by the manufacturer, distributor or by an expert, to avoid risks.

Schr der TFLEX COMBI LED Solution For Tunnel Lighting - icon 1

01-55-960 | DOC-0018753 rev M | 08-2022