Scheppach HC26Si-13A Compressor User Manual

Scheppach logoHC26Si-13A Compressor
User ManualScheppach HC26Si-13A Compressor

HC26Si / HC26Si-13A

Scheppach HC26Si-13A Compressor

Scheppach HC26Si-13A Compressor - QR CODE

https://www.scheppach.com/de/serviceScheppach HC26Si-13A Compressor - figScheppach HC26Si-13A Compressor - fig1

Explanation of the symbols on the product

Symbols are used in this manual to draw your attention to potential hazards. The safety symbols and the accompanying explanations must be fully understood. The warnings themselves will not rectify a hazard and cannot replace proper accident prevention
measures.

Scheppach HC26Si-13A Compressor - icon Warning – Read the operating manual to reduce the risk of injury.
Scheppach HC26Si-13A Compressor - icon 1 Wear hearing protection. Exposure to noise can cause hearing loss.
Scheppach HC26Si-13A Compressor - icon2 Wear a dust protection mask. When machining wood and other materials, harmful dust may be generated. Do not machine material containing asbestos!
Scheppach HC26Si-13A Compressor - icon3 Wear safety goggles. Sparks created during work or fragments, chippings and dust ejected by the product can cause sight loss.
Scheppach HC26Si-13A Compressor - icon4 Warning of hot surfaces.
Scheppach HC26Si-13A Compressor - icon5 Warning against electrical voltage.
Scheppach HC26Si-13A Compressor - icon6 Warning! The product is equipped with an automated start-up control. Keep third-parties away from the working range of the product!
Scheppach HC26Si-13A Compressor - icon7 Observe warning and safety instructions!
Scheppach HC26Si-13A Compressor - icon8 Do not expose the machine to rain. The product may only be stationed, stored and operated in dry ambient conditions.
Scheppach HC26Si-13A Compressor - icon9 Specification of the sound power level in dB.
CE The product complies with the applicable European directives.
Scheppach HC26Si-13A Compressor - icon10 The product complies with the applicable Serbian directives.

Introduction

Manufacturer:
Scheppach GmbH
Günzburger Straße 69
D-89335 Ichenhausen

Dear Customer,
We hope your new product brings you much enjoyment and success.
Note:
In accordance with the applicable product liability laws, the manufacturer of this product assumes no liability for damage to the product or caused by the product arising from:

  • Improper handling
  • Failure to comply with the operating manual
  • Repairs carried out by third parties, unauthorised specialists
  • Installing and replacing non-original spare parts
  • Improper use
  • Failures of the electrical system due to failure to observe the national electrical requirements and regulations

Note:
The operating manual is part of this product. It includes important instructions for the safe, proper and economic operation of the product, for avoiding danger, for minimising repair costs and downtimes and for increasing the reliability and extending the service life of the product. In addition to the safety instructions in this operating manual, you must also observe the regulations applicable to the operation of the product in your country. Familiarise yourself with all operating and safety instructions before using the product. Only operate the product as described and for the specified areas of application. Keep the operating manual in a good place and hand over all documents when passing the product on to third parties.

Product description (Fig. 1-6)

  1. Transport handle
    1a. Grub screw (transport handle)
  2. Pressure switch
  3. On/off switch
  4. Air filter
    4a. Screw (air filter)
    4b. Filter element
  5.  Pressure gauge (set pressure can be read off)
  6. Pressure regulator
  7. Safety valve
  8. Quick coupling (regulated compressed air)
  9. Pressure vessel
  10. Wheel
    10a. Screw (wheel)
    10b. Nut (wheel)
  11. Drain screw for condensate
  12. Foot
    12a. Screw (foot)
    12b. Nut (foot)

Scope of delivery

Item Quantity Designation
1x Machine body
1 1x Transport handle
4 1x Air filter (pre-installed)
10 2x Wheel
12 1x Foot
1x incl. 13-piece accessory set (for article number 59061659953)  (not shown)
1x Assembly material
1x Operating manual

Proper use

The compressor is used to generate compressed air for pneumatically powered tools that can be operated  with an air rate of up to 100 l/min. (e.g. tyre inflators, air blow guns, paint spray guns). Due to the limited air output it is not possible to use the compressor to drivetools with very high air consumption (for example orbital sanders, die grinders and hammer screwdrivers). The compressor may only be operated in a dry and well ventilated indoor space.

The machine may only be used in the intended manner. Any use beyond this is improper.
The user/operator, not the manufacturer, is responsible for damages or injuries of any type resulting from this.
Please note that our products were not designed with the intention of use for commercial or industrial purposes. We assume no guarantee if the product is used in commercial or industrial applications, or for equivalent work.

General safety instructions

Warning  WARNING – Read all safety information, instructions, illustrations and technical data for this power tool.
Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference.
The term “power tool” in the warnings refers to your mains-operated (corded) power tool or battery-operated (cordless) power tool.

  1. Work area safety
    a) Keep work area clean and well lit. Cluttered or dark areas invite accidents.
    b) Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or fumes.
    c) Keep children and bystanders away while operating a power tool. Distractions can cause you to lose control
  2. Electrical safety
    a) Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching outlets will reduce risk of electric shock.
    b) Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is earthed or grounded.
    c) Do not expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock.
    d) Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock.
    e) When operating a power tool outdoors, use an extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock.
    f) If operating a power tool in a damp location is unavoidable, use a residual current device (RCD) protected supply. Use of an RCD reduces the risk of electric shock.
  3. Personal safety
    a) Stay alert, watch what you are doing and use common sense when operating a power tool. Do not use a power tool while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating power tools may result in serious personal injury.
    b) Use personal protective equipment. Always wear eye protection. Protective equipment such as a dust mask, non-skid safety shoes, hard hat or hearing protection used for appropriate conditions will reduce personal injuries.
    c) Prevent unintentional starting. Ensure the switch is in the off-position before connecting to power source and/or battery pack, picking up or carrying the tool. Carrying power tools with your finger on the switch or energising power tools that have the switch on invites accidents.
    d) Remove any adjusting key or wrench before turning the power tool on. A wrench or a key left attached to a rotating part of the power tool may result in personal injury.
    e) Do not overreach. Keep proper footing and balance at all times. This enables better control of the power tool in unexpected situations.
    f) Dress properly. Do not wear loose clothing or jewellery. Keep your hair and clothing away from moving parts. Loose clothes, jewellery or long hair can be caught in moving parts.
    g) If devices are provided for the connection of dust extraction and collection facilities, ensure these are connected and properly used. Use of dust collection can reduce dust-related hazards.
    h) Do not let familiarity gained from frequent use of tools allow you to become complacent and ignore tool safety principles. A careless action can cause severe injury within a fraction of a second.
  4. Power tool use and care
    a) Do not force the power tool. Use the correct power tool for your application. The correct power tool will do the job better and safer at the rate for which it was designed.
    b) Do not use the power tool if the switch does not turn it on and off. Any power tool that cannot be controlled with the switch is dangerous and must be repaired.
    c) Disconnect the plug from the power source and/or remove the battery pack, if detachable, from the power tool before making any adjustments, changing accessories, or storing power tools. Such preventive safety measures reduce the risk of starting the power tool accidentally.
    d) Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool. Power tools are dangerous in the hands of untrained users.
    e) Maintain power tools and accessories. Check for misalignment or binding of moving parts, breakage of parts and any other condition that may affect the power tool’s operation. If damaged, have the power tool repaired before use. Many accidents are caused by poorly maintained power tools.
    f) Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control.
    g) Use the power tool, accessories and tool bits etc. in accordance with these instructions, taking into account the working conditions and the work to be performed. Use of the power tool for operations different from those intended could result in a hazardous situation.
    h) Keep handles and grasping surfaces dry, clean and free from oil and grease. Slippery handles and grasping surfaces do not allow for safe handling and control of the tool in unexpected situations.
  5. Service
    a) Have your power tool serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the power tool is maintained.

Safety instructions for compressors
Warning Attention! The following basic safety measures must be observed when using this compressor for protection against electric shock, and the risk of injury and fire. Read and observe these instructions before using the Product.

Safe work.

  1. Take care of your tools
    – Keep your compressor clean in order to work well and safely.
    – Follow the maintenance instructions.
    – Check the connection cable of the electric tool regularly and have it replaced by a recognised specialist when damaged.
    – Check extension cables regularly and replace them when damaged.
  2. Pull the connector out of the socket
    – When the power tool is not in use or prior to main- tenance and when replacing tools such as saw blades, drill bits, cutters.
  3. Check the power tool for potential damage
    – Protective devices or other parts with minor dam- age must be carefully inspected to ensure that they function correctly and as intended prior to continued use of the power tool.
    – Check whether the moving parts function faultlessly and do not jam or whether parts are damaged. All parts must be correctly mounted and all conditions must be fulfilled to ensure fault-free operation of the power tool.
    – Damaged protective devices and parts must be repaired as intended or replaced by a recognised specialist workshop unless otherwise specified in the operating instructions.
    – Do not use any faulty or damaged connection cables.
  4. Attention!
    – For your own safety, only use accessories and additional equipment that are indicated in the operating manual or have been recommended or indicated by the manufacturer. Use of other tools or accessories that those recommended in the operating manual or in the catalogue could represent a personal danger to you.
  5. Inflating tyres
    – Check the tyre pressure immediately after filling using a suitable pressure gauge, e.g. at a petrol station.
  6. Street
    -legal compressors in construction site operation – Ensure that all hoses and fixtures are suitable for the maximum permissible working pressure of the compressor.
  7. Set-up location
    – Only set up the compressor on a flat surface.
  8. It is recommended to equip the feed hoses with a safety cable in cases where the pressure is above 7 bar, e.g. using a wire cable.
  9. Avoid over-stressing the piping system by using flexible hose connections to prevent kinking.

ADDITIONAL SAFETY INSTRUCTIONS

Observe the corresponding operating manuals of the respective compressed air tools / compressed air attachments! The following general instructions must also be observed: 
Safety instructions for working with compressed air and air blow guns

  • Ensure there is sufficient distance to the product, at least 2.50 m, and keep the compressed air tools / compressed air attachments away from the compressor during operation.
  • Compressor pump and lines reach high temperatures during operation. Touching them will cause burns.
  • The air which is sucked in by the compressor must be kept free of impurities that could cause fires or explosions in the compressor pump.
  • When disconnecting the hose coupling, hold the coupling piece of the hose firmly with your hand. This will ensure that you avoid injuries caused by the hose recoiling.
  • Wear safety goggles when working with the air blow gun. Foreign objects or blown off parts can easily cause injuries.
  • Wear safety goggles and a respirator when working with the compressed air pistol. Dusts are harmful to health! Foreign objects or blown off parts can easily cause injuries.
  • Do not blow on people or clean clothing whilst on the body with the air blow gun. Danger of injury!

Safety instructions when using spraying attachments (e.g.paint sprayers): 

  1. Keep the spray attachment away from the com-pressor when filling so that no liquid comes into contact with the compressor.
  2.  Never spray in the direction of the compressor when using the spraying attachments (e.g. paint sprayers). Moisture can lead to electrical hazards!
  3. Do not process any paints or solvents with a flash point below 55° C. Risk of explosion!
  4.  Do not heat up paints or solvents. Risk of explosion!
  5.  If harmful liquids are processed, filter devices (face masks) are required for protection. Also observe the information on protective measures provided by the manufacturers of such substances.
  6. The information and labelling of the hazardous substances ordinance affixed to the outer packaging of the processed materials must be observed. If necessary, take additional protective measures, in particular wear suitable clothing and masks.
  7. Do not smoke during the spraying process or in the working area. Risk of explosion! Paint vapours are also highly flammable.
  8. Fireplaces, naked flames lights or sparking machinery must not be present or operated.
  9. Do not store or consume food or drinks in the work area. Paint fumes are harmful to health.
  10. The working area must be larger than 30 m³ and sufficient air exchange must be ensured during spraying and drying.
  11. Do not spray into the wind. Always observe the regulations of the local police authorities when spraying flammable or hazardous spraying materials.
  12. Do not use media such as white spirit, butyl alcohol and methylene chloride in conjunction with the PVC pressure hose.
  13. These media destroy the pressure hose.
  14. The work area must be separated from the com- pressor so that it cannot come into direct contact with the working medium.

Operation of pressure vessels

  • Anyone who operates a pressure vessel must keep this in good working order, operate and monitor it correctly, perform the necessary maintenance and servicing works immediately and implement safety measures as required according to the  circumstances.
  • The regulatory authority can instruct necessary monitoring measures in individual cases.
  •  A pressure vessel must not be operated if it exhibits a defect that poses a danger to personnel or third parties.
  • Check the pressure vessel for rust and damage each time before use. The compressor shall not be operated if the pressure vessel is damaged or rusty. If you discover damage, please contact the customer service workshop.

Warning! This power tool generates an electromagnetic field during operation. This field can impair active or passive medical implants under certain circumstances. In order to prevent the risk of serious or deadly injuries, we recommend that persons with medical implants consult with their physician and the manufacturer of the medical implant prior to operating the power tool. Store the safety instructions safely.

Residual risks

The machine has been built according to the state-of- the-art and the recognised technical safety require- ments. However, individual residual risks can arise during operation.

  • Health hazard due to electrical power, with the use of improper electrical connection cables.
  • Furthermore, despite all precautions having been met, some non-obvious residual risks may still remain.
  • Residual risks can be minimised if the “Safety Instructions” and the “Intended Use” together with the operating instructions as a whole are observed.
  • Avoid accidental starting of the machine: the operating button may not be pressed when inserting the plug in an outlet. Use the tool that is recommended in this operating manual. This is how to ensure that your machine provides optimum performance.
  • Keep your hands away from the working area when the machine is in operation.

Technical data

Mains power connection 230 V~ 50Hz
Engine output 1100 W
Operating mode S1
Compressor speed 2,850 rpm
Pressure vessel volume approx. 24 l
Operating pressure approx. 8 bar
Theo. Suction capability approx. 230 l/min
Theo. Power output approx. 100 l/min
Protection category IP 30
Weight approx. 18.2 kg
Max. installation altitude (above sea level) 1000 m

Subject to technical changes!
Noise and vibration
Warning Warning: Noise can have serious effects on your health. If the machine noise exceeds 85 dB, please wear suitable hearing protection.
Noise data

Sound power level L WA 85 dB
Sound pressure level L pA 66 dB
Uncertainty K wa/pA 3 dB

The noise emission values have been determined in accordance with EN ISO 3744:1995.
Note: The total vibration emission values specified and the device emissions values specified have been measured in accordance with a standardised test procedure and can be used for comparison of one electric tool with another.
Note: The tot a l v i brat i on em i ss i on va l ues spec i fied and the device emissions values specified can also be used for an initial estimation of the load.
Warning: The vibration values and noise emission values can vary from the specified values during the actual use of the power tool, depending on the type and the manner in which the power tool is used, and in particular the type of workpiece being processed.
Warning: It is necessary to determine the safety measures for the protection of the operator based on an assessment of the vibration load during the actual conditions of use (In doing so, all parts of the operating cycle must be taken into account such as times in which the power tool is switched off or times in which it is switched on, but is not running under a load).

Unpacking

  • Open the packaging and carefully remove the product.
  • Remove the packaging material, as well as the packaging and transport safety devices (if present).
  • Check whether the scope of delivery is complete.
  • Check the product and accessory parts for transport damage. In the event of complaints the carrier must be informed immediately. Later claims will not be recognised.
  • If possible, keep the packaging until the expiry of the warranty period.
  • Familiarise yourself with the product by means of the operating manual before using for the first time.
  • With accessories as well as wearing parts and replacement parts use only original parts. Spare parts can be obtained from your specialist dealer.
  • When ordering please provide our article number as well as type and year of manufacture for the product.

Warning WARNING!
The product and the packaging material are not children’s toys! Do not let children play with plastic bags, films or small parts! There is a danger of choking or suffocating!

Before commissioning

  • Before connecting, make certain that the data on the type plate matches with the mains power data.
  • Check the product for transport damage. Report any damage immediately to the transport company which was used to deliver the compressor.
  • Install the compressor near the point of consumption.
  • Long air lines and supply cables (extension cable) should be avoided.
  • Ensure that the intake air is dry and dust-free.
  • Do not install the compressor in a damp or wet room.
  • Operate the compressor only in suitable areas (well ventilated, ambient temperature +5°C to 40°C). There must be no dust, acids, vapours, explosive gases or inflammable gases in the room.
  • The compressor is designed to be used in dry rooms. It must not be used in areas where splashed water is present.
  • The compressor may only be used outdoor briefly when the ambient conditions are dry.
  • The compressor must always be kept dry and must not be left outdoors after work is complete.

Assembly and operation

Warning Attention!
Always make sure the product is fully assembled before commissioning!
You require the following for assembly: 1x socket spanner 12 mm, open-end spanner 13 mm and 17 mm. (not included in the scope of delivery)
10.1 Fitting the transport handle (Fig. 3)
• Fit the supplied transport handle (1) as shown.
10.2 Fitting the wheels (fig. 4)
• Fit the wheels (10) provided as shown.
10.3 Fitting the foot (Fig. 5)
• Fit the foot (12) provided as shown in.
10.4 Mains power connection

  • The compressor is equipped with a mains cable with an earthed plug. This can be connected to any 220‒240 V~ 50 Hz protective contact socket, with fuse protection of at least 16 A.
  • Before you use the machine, make sure that the mains voltage is the same as the operating voltage and the machine power on the rating plate.
  • Long supply lines, as well as extensions, cable drums etc. cause voltage drop and can prevent the motor from starting.
  • At low temperatures below +5 °C, sluggishness may make starting difficult or impossible.

10.5 On/Off switch (fig. 1)

  • Pull the on/off switch (3) upwards to switch on the compressor.
  • Press the on/off switch (3) down to switch off.

10.6 Adjusting the pressure (fig. 1)

  • The pressure at the manometer (5) is adjusted with the pressure regulator (6).
  • The adjusted pressure can be drawn from the quick coupling (8).

10.7 Setting the pressure switch (fig. 1)

  • The pressure switch (2) is set at the factory.
    Cut-in pressure approx. 6 bar
    Cut-out pressure approx. 8 bar

10.8 Fitting the compressed air hose (fig. 1)

  • Connect the plug-in nipple of the compressed air hose (not included in the scope of delivery) to one of the quick-connect couplers (8). Then connect the compressed air tool to the quick coupling of the compressed air hose.

Electrical connection

The electrical motor installed is connected and ready for operation. The connection complies with the applicable VDE and DIN provisions. The customer’s mains connection as well as the extension cable used must also comply with these regulations.
When working with spray attachments and during temporary use outdoors, the product must be connected to a residual current circuit breaker with a trigger current of 30 mA or less.
11.1 Important information
In the event of overloading, the motor will switch itself off. After a cool-down period (time varies) the motor can be switched back on again.
11.2 Damaged electrical connection cable
The insulation on electrical connection cables is often damaged.
This may have the following causes:

  • Pressure points, where connection cables are passed through windows or doors.
  • Kinks where the connection cable has been improperly fastened or routed.
  • Places where the connection cables have been cut due to being driven over.
  •  Insulation damage due to being ripped out of the wall socket.
  •  Cracks due to the insulation ageing.

Such damaged electrical connection cables must not be used and are life-threatening due to the insulation damage.
Check the electrical connection cables for damage regularly. Ensure that the connection cables are disconnected from electrical power when checking for damage. Electrical connection cables must comply with the applicable VDE and DIN provisions. Only use connection cables of the same designation.
The printing of the type designation on the connection cable is mandatory.
11.3 AC motor

  • Before commissioning, ensure that the mains voltage matches with the operating voltage on the type plate.
  • Extension cables up to 25 m long must have a cross-section of 1.5 mm².

Connection type X
If the mains connection cable of this product is damaged, it must be replaced by a specially prepared mains connection cable which can be obtained  from the manufacturer or its service department.

Cleaning, maintenance and storage

Warning Attention!
Pull out the mains plug before carrying out any cleaning or maintenance work! Danger of injury due to electric  shocks!
Warning Attention!
Wait until the product has cooled down completely!
Danger of burning!
Warning Attention!
Depressurise the product before carrying out any cleaning or maintenance work! Danger of injury!
12 .1 Cleaning

  • Keep the product as free of dust and dirt as possible.
    Rub the product clean with a clean cloth or blow it off with compressed air at low pressure.
  • We recommend that you clean the product directly after every use.
  • Clean the product at regular intervals using a damp cloth and a little soft soap. Do not use aggressive cleaning agents or solvents; they could attack the plastic parts of the product. Make sure that no water can penetrate the product interior.
  • The hose and injection tools must be disconnected from the compressor before cleaning. The compressor must not be cleaned with water, solvents or similar.

12.2 Maintaining the pressure vessel (fig. 1) Attention!
To ensure a long service life for the pressure vessel (9), drain off the condensate after each use by opening the drain screw (11).
Release the vessel pressure beforehand (see 12.6.1). The drain screw (11) is opened by turning it anti-clockwise (when looking at the screw on the bottom of the compressor) so that the condensate can be completely drained out of the pressure vessel (9).
Then close the drain screw (11) again (turn it clockwise). Check the pressure vessel (9) for rust and damage each time before use.
The compressor shall not be operated if the pressure vessel (9) is damaged or rusty.
If you discover damage, please contact the customer service workshop.
Instructions on the disposal of condensate:
Dispose of the condensate in accordance with local and national environmental regulations. Ensure that it is not discharged into the wastewater system.
12.3 Safety valve (Fig. 2)
The safety valve (7) is set to the maximum permissible pressure of the pressure vessel (9). It is not permitted to adjust the safety valve (7) or to remove the connection lock (7b) between the drain nut (7a) and its cap (7c). Actuate the safety valve (7) every 30 operating hours but at least 3 times a year to ensure that it works when required.
Turn the perforated exhaust nut (7a) anti-clockwise to open it and use your hands to pull the valve rod outwards over the perforated exhaust nut (7a) to open the outlet of the safety valve (7). Now, the valve audibly releases air. Then, tighten the exhaust nut (7a) clockwise again.
12.4 Cleaning the air filter (Fig. 6)
The air filter (4) prevents dust and dirt being sucked in. It is essential to clean this air filter (4) after at least every 300 hours in service. A blocked air filter (4) significantly reduces the compressor power. Remove the screw (4a) on the air filter (4) to remove it.  You can now remove the filter insert (4b). Carefully knock out the air filter insert (4b). These components must then be blown out with compressed air (approx. 3
bar) and reassembled in reverse order.
12.5 Service information
With this product, it is necessary to note that the following parts are subject to natural or usage-related wear, or that the following parts are required as consumables. Wearing parts*: Air filter
* may not be included in the scope of delivery!
Connections and repairs
Connections and repair work on the electrical equipment may only be carried out by electricians.
Please provide the following information in the event of any queries:
• Type of current for the motor
• Machine data – type plate
• Motor data – type plate
Spare parts and accessories can be obtained from our Service Centre. To do this, scan the QR code on the front page.
12.6 Storage 
Warning Attention!
Disconnect the mains plug, vent the product and all connected compressed air tools.
Store the compressor in such a way that it cannot be used by unauthorised persons.
Warning Attention!
Store the compressor only in dry locations that are inaccessible for unauthorised persons. Do not tilt the unit, only store it upright!
12.6.1 Releasing excess pressure
Release overpressure in the compressor by switching off the compressor and using up the compressed air still in the pressure vessel (9), e.g. with a compressed air tool running at idle or with an air blow gun.

Transport (Fig. 3)

Use the transport handle (1) to transport the device, and drive the compressor with it.
When lifting the compressor, note its weight (see Technical data).
Ensure that the load is well secured when transporting the compressor in a motor vehicle.

Disposal and recycling

Notes for packaging

Scheppach HC26Si-13A Compressor - icon11 The packaging materials are recyclable. Please dispose of packaging in an environmentally friendly manner.
Notes on the electrical and electronic equipment act (ElektroG)
WEE-Disposal-icon.png Waste electrical and electronic equipment does not belong in household waste, but must be collected and disposed of separately!

  • Used batteries or rechargeable batteries that are not installed permanently in the old device must be removed non-destructively before disposal! Their disposal is regulated by the battery act.
  • Owners or users of electrical and electronic devices are legally obliged to return them after use.
  • The end user is responsible for deleting their personal data from the old device being disposed of!
  • The symbol of the crossed-out dustbin means that waste electrical and electronic equipment must not be disposed of with household waste.
  • Waste electrical and electronic equipment can be handed in free of charge at the following places:
    – Public disposal or collection points (e.g. municipal works yards).
    – Points of sale of electrical devices (stationary and online), provided that dealers are obliged to take them back or offer to do so voluntarily.
    – Up to three waste electrical devices per type of device, with an edge length of no more than 25 centimetres, can be returned free of charge to the manufacturer without prior purchase of a new device from the manufacturer or taken to another authorised collection point in your vicinity.
    – Further supplementary take-back conditions of the manufacturers and distributors can be ob- tained from the respective customer service.

 Troubleshooting

The following table shows fault symptoms and describes remedial measures in the event of your machine failing to work properly. If you cannot localise and rectify the problem with this, please contact your service workshop.

Fault Possible cause Remedy
The compressor does not start. Mains voltage not present. Check cable, mains plug, fuse and socket.
Mains voltage too low. Avoid extension cables that are too long. Use exten­sion cables with sufficient conductor cross-section.
Outdoor temperature too low. Do not operate at outside temperatures below +5°C.
Motor is overheated. Allow the motor to cool down. If necessary, remedy the cause of the overheating.
Compressor runs, but no pressure. The safety valve leaks. Contact your local service centre. Only allow qualified personnel to carry out repairs.
The seals are damaged. Check the seals and have any damaged seals replaced by a service centre.
Drain screw for condensate leaking. Tighten the screw by hand. Check the seal on the screw and replace if necessary.
Compressor running, pressure shown on the manometer, but tools are not running. Hose connections leaking. Check compressed air hose and tools, replace if necessary.
Quick-coupler leaking. Contact your local service centre. Only allow qualified personnel to carry out repairs.
Pressure set too low at pressure regulator. Turn up the pressure regulator further.
EU Declaration of Conformity
(valid until 19.01.2027)
Translation of the original Declaration of Conformity
We declare under our sole responsibility that the product described here complies with the applicable directives and standards. 20/01/2027 – s 16. Déclarat
The object of the declaration described here fulfils the regulations of the directive 2011/65/EU of the European Parliament and Council  from 8th
June 2011, on the restriction of  the use  of certain hazardous substances in
electrical and electronic equipment.
* Technical documentation available at: ** 7 – scan the QR code) on UE de conformité (disponible en ligne à

Item number*** Item designation: Compressor HC26Si / HC26Si-13A Brand****
Scheppach HC26Si-13A Compressor - fig 6

Scheppach HC26Si-13A Compressor - fig 7Scheppach HC26Si-13A Compressor - fig8

Scheppach logowww.scheppach.com

Documents / Resources

PDF thumbnailHC26Si-13A Compressor
User Manual · Scheppach, Scheppach GmbH, HC26Si, HC26Si-13A, 5906165904, 59061659969, 59061659953, 5906165904_0510, 25 08 2026, air compressor

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.