SAVCH EL-OP-B2 Remote Keypad

SAVCH-EL-OP-B2-Remote-Keypad-PRO

Keypad dimensions and Installation dimensions

NOTE: When use remote keypad, SG+/SG-(RS485) serial communication function disabled.

Keypad dimensions

SAVCH-EL-OP-B2-Remote-Keypad-1

Keypad dimensions Installation

SAVCH-EL-OP-B2-Remote-Keypad-2

Remote keypad (EL-OP-B2) external dimensions and installation dimensions. (This keypad can be extended with ordinary network cable (8 cores))

Parameter function description

Parameter Parameter function Setting range Setup parameter
00-02 Main frequency source selection 0~5

6:Communication setting(Remote keypad) 7~9

6
00-11 Parameter initialization 0~2

3:Copy inverter parameters to keypad 4:Copy keypad parameters to Inverter

3 or 4

Remote keypad failure code description

Failure code Description Possible reason Corrective-measures
CErr Communication error Communication happen twice interrupted 1.Check if broken line occurs,or whether the peripheral equipment has a strong interference source 2.Return to the factory
EErr I2C communication error I2C communication error with MCU Return to the factory
uErr Inverter type no match Inverter type no match Use the correct inverter type
dErr Date invalid Date invalid Copy inverter parameters to keypad first
nErr Operation error Operation error Return to the factory