Satel INT-E Zone Expander Module

Full manual is available on www.satel.pl. Scan the QR code to go to our website and download the manual.

- The device should be installed by qualified personnel.
- Prior to installation, please read carefully the full manual.
- Changes, modifications or repairs not authorized by the manufacturer shall void your rights under the warranty.
- Disconnect power before making any electrical connections.
- Never connect power supply to the APS connector and terminals at the same time.
Tips for installation
- The expander should be installed indoors, in spaces with normal air humidity.
- Do not install the expander outdoors.
- To connect devices to the expander terminals, use flexible wires with a cross-section of 0.5-0.75 mm2.
- The expander requires 12 VDC power supply. You can connect power tothe APS connector (e.g. the APS-412 power supply by SATEL) or to the screw terminals (power from the control panel or additional power supply).
- The expander can be powered from the control panel, if the distance to the control panel does not exceed 300 m.
C/D communication bus
- Use an unshielded non-twisted cable. If you use the twisted-pair type of cable, remember that CLK (clock) and DAT (data) signals must not be sent through one twisted-pair cable.
- The wires must be run in one cable.
- The length of the cable must not exceed 600 m (VERSA / PERFECTA) or 1000 m (INTEGRA / ACCO-NT2 / CA-64).
RS communication bus
- Use a UTP cable (unshielded twisted pair).
- The length of the bus must not exceed 1000 meters.
- Place 120 Ω resistors at both ends of the bus.
- We recommend connecting the COM terminals of all devices on the bus with an additional cable.
Mounting
- Fasten the expander electronics board in the enclosure.
- If required, set the DIP switches accordingly (see full manual).
- Screw the communication bus wires to the expander terminals.
- If the expander is to report enclosure opening (tamper), connect the tamper switch wires to the TMP and COM terminals. If the expander is not to report enclosure opening (tamper), connect the TMP terminal to the COM terminal.
- Connect detectors to the expander zones.
- Depending on the selected method of expander powering, connect the power supply to the APS connector or screw the power wires to the +12V and COM terminals.
- Power on the expander.
- Depending on the requirements of the system in which the expander is installed, identify / add the expander. For more information, refer to the manual of the deviceto which the expander is connected.
Description of terminals
- Z1…Z8 – zones.
- COM – common ground.
- TMP – tamper input (NC) – if unused, it should be shorted to common ground.
- CLK – clock (C/D communication bus).
- DAT – data (C/D communication bus). +12V – +12 VDC power input / power output when the expander is powered by a power supply connected to the APS connector.
- A, B – RS communication bus.
The declaration of conformity may be consulted at www.satel.pl/ce
When no longer in use, this device may not be discarded with household waste. Electronic equipment should be delivered to a specialized waste collection center.
For information on the nearest waste collection center, please contact your local authorities. Help to protect the environment and natural resources by sustainable recycling of this device. Improper disposal of electronic waste is subject to fines.