SATEL APB-200 Panic Button User Manual

SATEL-logo

SATEL APB-200 Panic Button

SATEL-APB-200-Panic-Button-product

IMPORTANT

  • The device should be installed by qualified personnel.
  • Changes, modifications or repairs not authorized by the manufacturer shall void your rights under the warranty.

Description of symbols on the device:

SATEL-APB-200-Panic-Button-fig (1)

  • SATEL aims to continually improve the quality of its products, which may result in changes in their technical specifications and software. Current information about the changes being introduced is available on our website. Please visit us at: https://support.satel.pl
  • Hereby, SATEL sp. z o.o. declares that the radio equipment type APB-200 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce

Signs in this manualSATEL-APB-200-Panic-Button-fig (2)

The APB-200 button (Panic Button) is used to generate a panic alarm or call for help. It can be used to control the system. The manual applies to the button installed in the BE WAVE system.

Features

  • Signal sent after a single push.
  • Operation in the 868 MHz frequency band.
  • AES-encrypted two-way radio communication.
  • Transmission channel diversity – 4 channels for automatic selection of the one that will enable transmission without interference with other signals.
  • Remote settings programming.
  • Remote firmware update.
  • LED indicator.
  • Powered by a CR14250 3 V battery.
  • Battery status control.
  • Tamper protection against enclosure opening and removal from mounting surface.

Description

Electronics boardSATEL-APB-200-Panic-Button-fig (3)Figure 1 shows the inside of the button after removing the cover.

  1. battery holder (CR14250 3V).
  2. Tamper switch activated by removal from mounting surface.
  3. button.
  4. LED indicator. It flashes for about 5 seconds after inserting the battery (button warm-up). After that, it is only enabled while the diagnostics mode is started in the system. It indicates:
    • periodic communication – short flash.
    • button pressed – ON for 2 seconds.
  5. tamper switch activated by enclosure opening.
  6. fixing screw hole.

Installation

  • There is a danger of battery explosion when using a different battery than recommended by the manufacturer, or handling the battery improperly.
  • Do not crush the battery, cut it or expose it to high temperatures (throw it into the fire, put it in the oven, etc.).
  • Do not expose the battery to very low pressure due to the risk of battery explosion or leakage of flammable liquid or gas.
  • Be particularly careful during installation and replacement of the battery. The manufacturer is not liable for the consequences of incorrect installation of the battery.
  • If the device is mounted higher than 2 meters above the ground, it may cause harm if it falls off.

Tips for installation

  • The button should be installed indoors, in spaces with normal air humidity.
  • Do not install the button outdoors.
  • When selecting a place of installation, consider the radio communication range.
  • Thick walls, metal partitions, etc. reduce the range of the radio signal.

Mounting

  1. Remove the button cover (Fig. 2).SATEL-APB-200-Panic-Button-fig (4)
  2. Remove the electronics board (Fig. 3).SATEL-APB-200-Panic-Button-fig (5)
  3. Drill the holes for screws in the enclosure base (Fig. 4). We recommend to mount the enclosure base to the surface with 3 screws.SATEL-APB-200-Panic-Button-fig (6)
  4. Use screws to mount the enclosure base to the surface. If necessary, select appropriate wall plugs (anchors) based on the type of the mounting surface (different for concrete or brick wall, different for plaster wall, etc.).
    In order for the detector to detect removal from the surface, fasten the screw in the place marked with the T symbol in the figure 4.
  5. Fasten the electronics board.
  6. Add the button to the system (see the manual for the BE WAVE system controller or the BE WAVE Hybrid system control panel). When a request to turn on the device will be displayed, install the battery in the button.
  7. Replace the button cover (Fig. 5). The marks indicated by the i symbol in the figure 5 will help you close the enclosure.SATEL-APB-200-Panic-Button-fig (7)

Test

  1. Enable the diagnostics mode in the system (see the manual for the BE WAVE system controller or the BE WAVE Hybrid system control panel).
  2. Press the button to see if the LED indicator turns ON.
  3. Disable the diagnostics mode.

Battery replacement

The used batteries must not be discarded, but should be disposed of in accordance with the existing rules for environment protection. The Be Wave app will indicate that the battery in the button is low. The low battery should be replaced as soon as possible.

  1. In the Be Wave app / BE WAVE Soft program, tap / click the room in which the button is installed.
  2. Tap/click the button name.
  3. Start the Battery replacement function.
  4. Remove the button cover (Fig. 2).
  5. Remove the low battery.
  6. Wait 1 minute.
  7. Install the new battery.
  8. Replace the button cover.
  9. Start the Unbypass device function in the Be Wave app / BE WAVE Soft program.

Specifications

Operating frequency band 868.0 MHz ÷ 868.6 MHz
Radio communication range (in open area) up to 1200 m
Battery CR14250 3 V
Battery life expectancy up to 2 years
Standby current consumption 55 µA
Low battery voltage threshold 2.75 V
Environmental class according to EN 50130-5 II
Operating temperature range -10°C…+55°C
Maximum humidity 93±3%
Dimensions ø97 x 29 mm
Weight 73 g

Troubleshooting

  • LED does not turn ON during test: Enable diagnostics mode in the system, then press the button and check whether the LED turns ON. If the LED does not indicate during diagnostics, repeat the test with diagnostics enabled/disabled as described.
  • Battery is low: The Be Wave app indicates when the button battery is low. Replace the battery as soon as possible using the battery replacement procedure.
  • Button behavior after battery insertion: After inserting the battery, the LED flashes for about 5 seconds (button warm-up). After that, the LED is only enabled while diagnostics mode is started in the system.
  • Mounting/tamper concerns: Ensure the tamper detection screw is fastened at the T-marked location so the system can detect removal from the surface.

Documents / Resources

PDF thumbnailAPB-200 Panic Button
User Manual · SATEL, SATEL sp. z o.o., APB-200, apb-200_BW_en, Panic Button

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.