satel ACSP-RSI Remote Repeater Panels Instructions

ACSP-RSI Remote Repeater Panels

Product Information

Specifications:

  • Product Name: ACSP-RSI Fire Alarm Systems
  • System Type: ACSP System / Remote Repeater
    Panels
  • Current Consumption: Not specified
  • Operating Temperature Range: Not
    specified
  • Weight: Not specified
  • Maximum Humidity: Not specified
  • Dimensions: Not specified
  • Power Supply Voltage: Not specified

Product Usage Instructions:

The ACSP-RSI Fire Alarm Systems are designed to provide reliable
fire detection and alarm capabilities. Follow these steps for
proper usage:

1. Installation:

Ensure the system is installed by a qualified technician
following the provided installation guidelines.

2. Power Supply:

Connect the system to a compatible power supply voltage as
specified in the manual.

3. Activation:

Activate the system according to the manufacturer’s instructions
in case of a fire emergency.

4. Monitoring:

Regularly monitor the system for any alarms or malfunctions and
address them promptly.

5. Maintenance:

Schedule regular maintenance checks to ensure the system
functions properly at all times.

FAQ (Frequently Asked Questions):

Q: What should I do if the fire alarm system goes off
accidentally?

A: If the alarm goes off accidentally, you can silence it using
the provided reset button. However, make sure to investigate the
cause of the false alarm.

Q: Can I expand the ACSP-RSI system with additional remote
repeater panels?

A: Yes, you can expand the system by adding compatible remote
repeater panels following the manufacturer’s guidelines for
integration.

ACSP-RSI
The ACSP­RSI module is used for galvanic isolation of the ACSP­402 fire alarm control panel and APSP­402 repeater panel connected using the RS­485 bus. Owing to this, the repeater panel does not to be connected to the same protective earth circuit (PE) as the control panel. The module may be used for connecting a serial thermal printer which can provide printouts of events registered by the control panel. The module is an optional element of the ACSP addressable fire alarm system.
galvanic isolation of the RS­485 bus RS­485 port for connecting the ACSP­402 / APSP­402 repeater panel RS­485 port for connecting to a second ACSP­RSI module capability to connect a thermal serial printer 12…18 V DC power supply from the ACSP­402 control panel / APSP­402 repeater panel removable terminal blocks

FIRE ALARM SYSTEMS ACSP System / Remote repeater panels

Current consumption Operating temperature range Weight Maximum humidity Dimensions Power supply voltage

45 mA -10°C…+55°C
28 g 93±3% 61 x 51 mm 12…18 V DC

The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only.

www.satel.pl

Documents / Resources

satel ACSP-RSI Remote Repeater Panels [pdf] Instructions
ACSP-RSI Remote Repeater Panels, ACSP-RSI, Remote Repeater Panels, Repeater Panels, Panels

References

Leave a comment

Your email address will not be published. Required fields are marked *