ACSP-RSI Remote Repeater Panels
Product Information
Specifications:
- Product Name: ACSP-RSI Fire Alarm Systems
- System Type: ACSP System / Remote Repeater
Panels - Current Consumption: Not specified
- Operating Temperature Range: Not
specified - Weight: Not specified
- Maximum Humidity: Not specified
- Dimensions: Not specified
- Power Supply Voltage: Not specified
Product Usage Instructions:
The ACSP-RSI Fire Alarm Systems are designed to provide reliable
fire detection and alarm capabilities. Follow these steps for
proper usage:
1. Installation:
Ensure the system is installed by a qualified technician
following the provided installation guidelines.
2. Power Supply:
Connect the system to a compatible power supply voltage as
specified in the manual.
3. Activation:
Activate the system according to the manufacturer’s instructions
in case of a fire emergency.
4. Monitoring:
Regularly monitor the system for any alarms or malfunctions and
address them promptly.
5. Maintenance:
Schedule regular maintenance checks to ensure the system
functions properly at all times.
FAQ (Frequently Asked Questions):
Q: What should I do if the fire alarm system goes off
accidentally?
A: If the alarm goes off accidentally, you can silence it using
the provided reset button. However, make sure to investigate the
cause of the false alarm.
Q: Can I expand the ACSP-RSI system with additional remote
repeater panels?
A: Yes, you can expand the system by adding compatible remote
repeater panels following the manufacturer’s guidelines for
integration.
ACSP-RSI
The ACSPRSI module is used for galvanic isolation of the ACSP402 fire alarm control panel and APSP402 repeater panel connected using the RS485 bus. Owing to this, the repeater panel does not to be connected to the same protective earth circuit (PE) as the control panel. The module may be used for connecting a serial thermal printer which can provide printouts of events registered by the control panel. The module is an optional element of the ACSP addressable fire alarm system.
galvanic isolation of the RS485 bus RS485 port for connecting the ACSP402 / APSP402 repeater panel RS485 port for connecting to a second ACSPRSI module capability to connect a thermal serial printer 12…18 V DC power supply from the ACSP402 control panel / APSP402 repeater panel removable terminal blocks
FIRE ALARM SYSTEMS ACSP System / Remote repeater panels
Current consumption Operating temperature range Weight Maximum humidity Dimensions Power supply voltage
45 mA -10°C…+55°C
28 g 93±3% 61 x 51 mm 12…18 V DC
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only.
www.satel.pl
Documents / Resources
![]() |
satel ACSP-RSI Remote Repeater Panels [pdf] Instructions ACSP-RSI Remote Repeater Panels, ACSP-RSI, Remote Repeater Panels, Repeater Panels, Panels |