WQ615RF Thermostat and Receiver
“
Product Specifications:
- Model: WQ615RF
- Frequency: 2405-2480MHz
- Manufacturer: SALUS Controls
- Head Office Address: Units 8-10, Northfield Business Park,
Forge Way, Parkgate Rotherham, S60 1SD
Product Usage Instructions:
1. Installation:
Before installation, make sure to read the user manual
thoroughly. Follow these steps for installation:
- Locate a suitable place for both the thermostat and
receiver. - Mount the thermostat on the wall using appropriate
fixtures. - Connect the receiver to the heating system as per the provided
instructions.
2. Pairing:
To pair the thermostat with the receiver:
- Ensure both devices are powered on.
- Follow the pairing instructions in the user manual to establish
a connection between the thermostat and receiver.
3. Setting Temperature:
To set the desired temperature:
- Use the controls on the thermostat to adjust the temperature
settings. - Wait for the system to reflect the new temperature
setting.
Frequently Asked Questions (FAQ):
Q: How do I change the batteries in the thermostat?
A: To change the batteries, follow these steps:
- Locate the battery compartment on the back of the
thermostat. - Remove the old batteries and replace them with new ones,
ensuring correct polarity.
Q: Can I control multiple heating zones with this
thermostat?
A: Yes, you can control multiple heating zones by installing
additional receivers for each zone and pairing them with the main
thermostat following the provided instructions.
“`
THERMOSTAT & RECEIVER Model: WQ615RF
Quick Guide
HEAD OFFICE
SALUS Controls, Units 8-10, Northfield Business Park, Forge Way, Parkgate Rotherham, S60 1SD
SALUS Controls GmbH, Dieselstrasse 34, 63165 Mühlheim am Main, Germany
UK: tech@salus-tech.com DE / NL: info@salus-controls.de FR: technicalsupport@saluscontrols.fr RO: tehnic@saluscontrols.ro DK: Support@salus-controls.dk
www.saluscontrols.com
SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Protect which is made up SALUS Controls and Safe4 reserves the right to change specification, design and materials of products listed in this brochure without prior notice.
V01 XII/2024
The SALUS WQ615TX thermostat and WQ615RX receiver form a versatile package designed for effective management of electric heating systems utilizing the Zigbee protocol. This ultra-slim, wireless programmable thermostat is rechargeable and operates on a lithium-ion battery. The receiver can be set up as a master unit, allowing it to connect with up to four additional slave receivers, thereby creating a unified and synchronized network for controlling multiple infrared panels. Each WQ615RX receiver can function as either a master or a slave, depending on the system’s requirements, ensuring smooth control and integration. This flexibility allows for effortless management of the entire heating or cooling system, improving the efficiency and responsiveness of your setup.
These products comply with the essential requirements and other relevant provisions of Directives 2014/53/EU and 2015/863/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.saluslegal.com.
2405-2480MHz; <14dBm
To ensure both safety and optimal performance, the WQ615TX thermostat and the WQ615RX receiver should be used in accordance with all relevant regulations. These devices are designed exclusively for indoor use and must not be installed in environments exposed to extreme temperatures or other harsh conditions. Keep the receiver completely dry; any inadequate installation may cause damage or malfunction. Always disconnect the power before cleaning and use a dry cloth only. For safe operation, position the WQ615TX thermostat and install the WQ615RX receiver at a convenient height to allow easy access. The devices’ maximum operating temperature is 50°C, so avoid placing them in locations that may exceed this limit to prevent overheating.
WQ615TX Thermostat
1
2
3
4
5 16
15
14
6
Receiver buttons
1
2
3
1. MODE button: Auto/On/Off selection 2. Master/Slave selection: Master can control up to 4 slaves 3. PAIR button for quick pairing procedure
Wiring diagram
13 12 11 10 9 8
1. Menu/Settings + Clock 2. AM/PM 3. Temperature measurement unit 4. Heating indicator (icon is animated when there is heat demand) 5. Cooling indicator (icon is animated when there is cooling demand) 6. RF connection indicator 7. Locked keys indicator 8. OFF mode icon
9. Current temperature/ Set temperature 10. Vacation mode 11. Temporary change mode 12. Settings icon 13. Battery indicator 14. Current active program 15. Program mode icon 16. Day/Status indicator
Infrared panel
Power supply
Pairing process
Note: The WQ615TX thermostat comes prepaired with the WQ615RX receiver, which can also be linked to an additional 4 more receivers (5th slave will be rejected), all connected to infrared heating panels. To start a new pairing process, it is necessary to factory reset the devices.
1
2
3
Power up the receiver. PAIR LED will flash red. Slave LED will flash green.
4
Short press the Master/Slave button to change to Master.
10 s
Press and hold the PAIR button for 10 seconds to reset the master receiver.
5
6
The PAIR LED will show solid red for 5 seconds then will start flashing red.
7
5 s
Press and hold the PAIR button for 5 seconds to start pairing the master receiver.
8
Master LED and PAIR LED will both flash green.
9
A few seconds later, Master LED will show solid green. PAIR LED will keep flashing green.
5 s
Press and hold the PAIR button for 5 seconds.
Both PAIR and Master LEDs show solid green. Master receiver is now paired.
Pairing a slave receiver (optional)
Note: Skip steps 10 – 15 if you only pair one master receiver. Resume pairing from step 16.
10
11
12
Power up the slave receiver. PAIR LED will flash red. Slave LED will flash green.
10 s
Press and hold the PAIR button for 10 seconds to reset the slave receiver.
The Slave LED and PAIR LED will both start flashing green.
13
Master receiver
14
Master receiver
15
5 s
Press and hold the PAIR button for 5 seconds ON THE MASTER RECEIVER to start pairing the SLAVE receiver.
The PAIR LED on the master receiver will start flashing green.
Wait until Slave LED and PAIR LED both show solid green on the slave receiver. Slave receiver is now paired.
Note: Repeat the slave pairing process to connect up to a maximum of 4 slaves. · Resetting the master: master deletes the thermostat, all slaves and coordinator
information. · Resetting the slave: slave deletes its own connection information and leaves the
ZigBee network.
16
17
18
Press and hold the UP and DOWN buttons for 5 seconds to reset the thermostat.
19
Display will show all icons.
Choose English and press the YES button.
20
If paired successfully, the termostat will display [PAIRING SUCCESSFULL], then, after a few seconds, will go to the home screen.
21 After setting the temperature on the thermostat, receiver will show solid GREEN LEDs (AUTO, MASTER/SLAVE, PAIR).
Note: If the user wants to replace one or more existing paired slave receiver, user MUST let the WQ610TX thermostat, master and slave receivers do factory reset and pair again. In case of mistake or broken receivers, user will need to do factory reset of Master and then redo all pairing process of WQ610TX and Slaves.
Note: If master/slaves do not receive RF signal from master for over 1 hour in Auto mode, they will enter fail safe mode. In the fail safe mode, they will turn on relay for 5 min and turn off again for 55 min and repeat until RF signal is reconnected. When reconnected, slaves are re-controlled by master again. In manual ON or OFF mode, no fail safe mode.
Wiring diagram
Infrared panel
Power supply
Input Power Receiver rating max Outputs Radio frequency
ZigBee 2.4 GHz Rechargeable Li-Ion battery 10 (5) A 230V SL 2.4 GHz 0°C to 50°C -30°C to 50°C Class II
100mm(W) x 110mm(H) x 22mm (D)
Documents / Resources
![]() |
SALUS CONTROLS WQ615RF Thermostat and Receiver [pdf] User Guide WQ615RF Thermostat and Receiver, WQ615RF, Thermostat and Receiver, Receiver |