Key Features
- Display Backlight
- Internal & External Temperatures
- Min/Max Memory
- °C/°F Switchable
Setup and Installation
- Open the battery cover and remove the tab resting on the battery. Replace the battery cover.
- Connect the external temperature probe.
- Select the desired temperature unit (°F or °C) using the button on the back.
- Fully extend the probe wire.
- Choose a location to mount the thermometer. Attach the thermometer using the magnets on the back or the flip-out desk stand.
- Position the sensor in the desired location.
- Peel the clear protective sheet from the LCD display.
INT/EXT Function
Press INT/EXT to toggle between ambient (INT) and probe (EXT) temperature readings.
- INT displays the ambient temperature measured by the internal sensor.
- EXT displays the probe sensor temperature.
MIN/MAX Readings
Use the INT/EXT button to cycle through MAX/MIN readings.
- Press MAX/MIN once to display the maximum reading.
- Press MAX/MIN again to display the minimum reading.
- Press MAX/MIN a third time to return to normal display.
- Press and hold MAX/MIN for three seconds to reset the MAX/MIN memory.
- Always reset the memories before taking new maximum and minimum readings.
High/Low Temperature Alarm Setting (Probe Sensor Only)
- Press and hold ALARM SET until the display flashes. "HIGH" will appear.
- Press the °C/°F button on the back to set the desired high temperature limit.
- Press ALARM SET again. "LOW" will appear.
- Press the °C/°F button on the back to set the desired low temperature limit.
- Press ALARM SET to return to normal display.
- Pressing and holding the °C/°F button advances the values automatically.
- If the current temperature is outside the set limit, the alarm will sound until the alarm is silenced or the current reading returns to within the set limits.
- The alarm will sound for 50 seconds and then for 4 seconds every minute until muted.
- Press ALARM SET to silence the alarm.
Alarm ON/OFF
Press ALARM SET to switch the alarm on or off. "AL" will be displayed in the lower left corner of the display when the alarm is on. Press ALARM SET to silence the alarm when it is sounding.
Low Battery Indication
If the battery power becomes low, a [Low Battery Indicator Symbol] will appear on the display. Replace the battery with a CR2032 3V type.
Display Backlight
Press the LIGHT button to turn on the display backlight.
Technical Support
For warranty, service, and technical assistance, please contact ThermoWorks' Technical Support at (801) 756-7705 or email at techsupport@thermoworks.com.
Specifications
Feature | Specification |
---|---|
Measurement Range Internal Sensor | 14 to 122°F (-10 to 50°C) |
Measurement Range External Sensor | -58 to 158°F (-50 to 70°C) |
Display Accuracy | ±1°F (±0.5°C) between -4 to 122°F (-20 to 50°C), otherwise ±1.8°F (±1°C) |
Display Resolution | 0.1° |
Alarm Increments | High and low alarms settable in 1.8°F (1.0°C) increments |
Display Size | 0.8 H x 1.9 W inches (21 H x 48 W mm) |
Battery | 3 volt, CR2032 or equivalent x 1 piece (included) |
Battery Life | 10,000 hours |
Display Reading Update | 10 seconds |
Probe Cord Length | 9.8 feet (3 m) |
Product Size | 2 H x 2.9 W x 0.7 D inches (52 H x 73 W x 18 D mm) |
About ThermoWorks, Inc.
ThermoWorks, Inc.
Utah, U.S.A.
Ph: 801-756-7705
Fax: 801-756-8948
www.thermoworks.com
Follow Us
Connect with ThermoWorks on social media: [Facebook] [Twitter] [YouTube] [Instagram] [Pinterest]
Manufacturing & Compliance
Made in China
CE