SIMPLEX 4010 9403

Руководство пользователя адресного блока управления пожарной сигнализацией Simplex 4010-9403 4010ES

Model: 4010 9403 | Brand: SIMPLEX

1. Введение

This manual provides essential information for the proper installation, operation, and maintenance of the Simplex 4010-9403 4010ES Addressable Fire Control Unit. This unit is designed to provide reliable fire detection and alarm capabilities for various applications. Please read this manual thoroughly before attempting any installation or operation.

2. Информация по технике безопасности

Always adhere to local and national electrical codes and fire safety regulations during installation and operation. Only qualified personnel should install, service, or maintain this equipment. Disconnect all power sources before servicing. Failure to follow these instructions may result in injury, death, or property damage.

3. Продукт закончилсяview

The Simplex 4010ES Addressable Fire Control Unit (FCU) is a robust system designed for comprehensive fire detection and notification. It features an addressable loop for connecting various fire alarm devices such as smoke detectors, heat detectors, and manual pull stations. The unit is housed in a durable red enclosure with a clear LED display for status indication.

Передний view of the Simplex 4010ES Addressable Fire Control Unit, showing the red enclosure and the control panel with LED display and buttons.

Рисунок 3.1: Передняя часть view of the Simplex 4010ES Addressable Fire Control Unit. The unit is red with a dark grey control panel featuring a green LED display and various buttons and indicators.

The unit operates on 120V AC power and includes a battery backup system to ensure continuous operation during power outages. The front panel provides access to system controls, status indicators, and a key lock for secure access.

4. Настройка и установка

4.1 Распаковка и осмотр

Carefully unpack the fire control unit and inspect it for any signs of shipping damage. Verify that all components listed in the packing slip are present. The unit's part number is 0743904, and the PID is 4010-9403, as indicated on the packaging.

Shipping label on a cardboard box for the Simplex 4010-9403, showing PID, Part No. 0743904, and Serial Number.

Figure 4.1: Product identification label on the shipping box, displaying the PID (4010-9403), Part No. (0743904), and serial number for the Simplex 4010ES FACP.

Accessories included with the Simplex 4010ES unit, including a key and cable ties, with a partial view of the control panel in the background.

Figure 4.2: Included accessories such as the system key and cable ties, essential for installation and secure operation.

4.2 Монтаж устройства

Select a clean, dry, and secure location for mounting the unit, away from direct sunlight and heat sources. Ensure adequate space for ventilation and access for servicing. Mount the unit securely to a wall using appropriate fasteners, ensuring it is level and stable.

4.3 Электрические соединения

The unit requires a 120V AC power supply. All wiring must comply with national and local electrical codes. Connect the main power supply to the designated terminals inside the unit. Ensure proper grounding. Install backup batteries as per the wiring diagram provided with the unit.

4.4 Подключение устройства

Connect addressable fire alarm devices (detectors, modules, pull stations) to the unit's addressable loop terminals. Follow the specific wiring diagrams for each device type to ensure correct addressing and functionality. Verify all connections are secure before applying power.

5. Инструкция по эксплуатации

5.1 Включение

Once all connections are complete and verified, apply main AC power to the unit. The unit will perform a self-diagnostic test. Observe the LED indicators for system status. The green 'POWER' LED should illuminate steadily.

5.2 Понимание индикаторов

5.3 Реагирование на сигналы тревоги

  1. Upon an alarm, the red ALARM LED will illuminate, and audible signals will activate.
  2. Immediately investigate the cause of the alarm.
  3. To silence the audible alarm, press the ТИШИНА кнопка.
  4. Once the cause of the alarm is resolved, press the ПЕРЕЗАГРУЗИТЬ button to clear the alarm condition and restore the system to normal operation.
  5. If the alarm persists or cannot be reset, refer to the Troubleshooting section or contact qualified service personnel.

6. Техническое обслуживание

Regular maintenance is crucial for the reliable operation of your fire control unit. Perform the following checks periodically:

7. Поиск Неисправностей

This section provides solutions to common issues you may encounter with your Simplex 4010ES unit. For problems not listed here, contact qualified service personnel.

ПроблемаВозможная причинаРешение
Unit has no power (no LEDs).No AC power; tripped circuit breaker; dead battery.Check AC power supply; reset circuit breaker; check/replace backup battery.
TROUBLE LED is illuminated.Wiring fault; device malfunction; low battery.Check wiring connections; inspect devices; test/replace battery. Consult system logs for specific trouble codes.
Ложные тревоги.Dust/debris in detectors; environmental factors; faulty device.Clean detectors; identify and mitigate environmental factors (e.g., steam); replace faulty device.
System will not reset.Alarm condition still present; system fault.Ensure all alarm conditions are cleared; check for trouble signals. If issue persists, contact service.

8. Технические характеристики

ОсобенностьДеталь
БрендСИМПЛЕКС
Номер модели4010 9403
Номер деталиС40109403
СКП767571882953
Источник питания120V AC, Battery Powered (Backup)
ЦветКрасный
Тип сигнала тревогиВизуальный
ПроизводительСИМПЛЕКС
Количество в упаковке1

9. Гарантия и поддержка

For specific warranty information regarding your Simplex 4010-9403 4010ES Addressable Fire Control Unit, please refer to the documentation provided at the time of purchase or contact your authorized Simplex distributor. Simplex is committed to providing excellent customer service and support for its products.

If you require technical assistance, service, or have questions regarding your unit, please contact Simplex customer support or an authorized service provider. Contact information can typically be found on the manufacturer's official webили через вашего местного дистрибьютора.

Связанные документы - 4010 9403

Предварительноview Simplex 4010ES Addressable Fire Detection and Control Units: Modules and Accessories
Comprehensive guide to Simplex 4010ES Addressable Fire Detection and Control Units, detailing features, modules, accessories, specifications, and installation.
Предварительноview Инструкции по установке Simplex IDNet Signal IAM
Подробные инструкции по установке модуля индивидуального адресного сигнального адаптера Simplex 4090-9007 IDNet (Signal IAM), охватывающие настройку адреса, конфигурацию проводки для цепей устройств оповещения (NAC) классов A и B, а также процедуры монтажа. Данное руководство содержит важную информацию по интеграции Signal IAM с панелями управления пожарной сигнализацией и устройствами оповещения.
Предварительноview Симплексные адресуемые ручные станции: периферийные устройства IDNet/MAPNET II
Ознакомьтесь с адресными ручными пожарными станциями Simplex, подробно описав их характеристики, типы одинарного/двойного действия, опции NO GRIP и совместимость с системами IDNet/MAPNET II. Включает информацию о монтаже и технических характеристиках.
Предварительноview Simplex 4010ES: Автоматические системы управления тушением для жиклеров
Техника руководства Simplex 4010ES содержит подробные сведения о модулях команд для автоматических систем гасания, о режимах затопления и предотвращения, со спецификациями, омологациями и схемами кабелей.
Предварительноview Техническое описание устройства обнаружения и контроля пожара Simplex 4007ES
Подробный технический паспорт на блок обнаружения и управления пожаром Simplex 4007ES, охватывающий его возможности, функции, технические характеристики и сведения об установке цифровой адресной инициализации и адресного оповещения MX.
Предварительноview Simplex 4090-9007 IDNet Signal IAM: адресный модуль для систем пожарной сигнализации
Подробные технические характеристики и функции индивидуально-адресного модуля сигнализации Simplex 4090-9007 IDNet (IAM), предназначенного для расширенной избирательной сигнализации и управления звуком в панелях управления пожарной сигнализацией Simplex серий 4100ES, 4010ES, 4100U и 4008. Включает информацию о подключении, эксплуатации и монтаже.