APOLLO 69ELF114TWG

Apollo 3/4" Bronze Double Union Threaded Water Pressure Regulator with Gauge Instruction Manual

Model: 69ELF114TWG

1. Продукт закончилсяview

The Apollo 3/4" Bronze Double Union Threaded Water Pressure Regulator with Gauge (Model 69ELF114TWG) is designed to reduce incoming water pressure to a safe and consistent level for residential and commercial plumbing systems. This unit features a compact design, lead-free bronze construction, and an integrated internal bypass mechanism. It includes a color-coded gauge for easy pressure monitoring and adjustment.

Apollo 3/4 inch Bronze Water Pressure Regulator with Gauge

Figure 1: Apollo 3/4" Bronze Double Union Threaded Water Pressure Regulator with Gauge. This image shows the regulator with its integrated pressure gauge and yellow adjustment handle.

2. Информация по технике безопасности

3. Содержимое упаковки

Перед началом установки убедитесь, что все компоненты присутствуют:

4. Установка

This regulator features a double union PEX-A (cold expansion) barb design for simplified installation in PEX-A piping systems. Ensure the regulator is installed in the correct flow direction, indicated by an arrow on the body.

  1. Подготовьте место установки: Turn off the main water supply. Drain the water lines to relieve pressure. Select a suitable location for the regulator, typically after the main shut-off valve and before any branch lines.
  2. Cut and Prepare PEX-A Piping: Cut the PEX-A pipe to the required length, ensuring clean, square cuts. Prepare the pipe ends for cold expansion connections according to PEX-A system manufacturer guidelines.
  3. Connect the Regulator:
    • Apply appropriate thread sealant (e.g., Teflon tape or pipe dope) to the male threads of the PEX-A fittings.
    • Thread the PEX-A fittings onto the double union ends of the regulator. Ensure the flow arrow on the regulator body points in the direction of water flow into the building.
    • Tighten the union nuts securely, but do not overtighten.
    • Perform cold expansion connections on the PEX-A pipe ends to the fittings according to PEX-A system manufacturer instructions.
  4. Установите манометр: The pressure gauge is typically pre-installed. Ensure it is securely threaded into the designated port on the regulator body.
  5. Restore Water Supply and Check for Leaks: Slowly turn on the main water supply. Carefully inspect all connections for any signs of leaks. Tighten connections as necessary.
Apollo Water Pressure Regulator with PEX-A connections

Рисунок 2: Сторона view of the Apollo Water Pressure Regulator, showing the double union PEX-A connections and the flow direction arrow. Note the "MAX INLET 400 PSI" marking.

5. Инструкция по эксплуатации

The regulator is factory-set at 50 psi and is adjustable from 15 psi to 75 psi. No special tools are required for adjustment.

  1. Проверьте текущее давление: Observe the reading on the integrated pressure gauge. The gauge is color-coded to indicate pressure ranges (e.g., Low, Optimal, Excessive).
  2. Регулировка давления:
    • К увеличивать pressure: Turn the yellow adjustment handle по часовой стрелке.
    • К снижаться pressure: Turn the yellow adjustment handle против часовой стрелки.
    • Make small adjustments and allow the system pressure to stabilize before re-checking the gauge.
  3. Подтвердите настройку: Once the desired pressure is achieved (typically between 50-60 psi for most residential applications), confirm the reading on the gauge.
Apollo Water Pressure Regulator with gauge showing optimal pressure range

Рисунок 3: Крупный план view of the Apollo Water Pressure Regulator, highlighting the pressure gauge with its color-coded optimal range and the yellow adjustment handle.

6. Техническое обслуживание

The Apollo Water Pressure Regulator is designed for minimal maintenance. Regular checks can help ensure optimal performance.

7. Поиск Неисправностей

ПроблемаВозможная причинаРешение
No water flow or very low pressure downstreamRegulator set too low; Main water supply off; Regulator clogged.Increase pressure setting; Check main water valve; Inspect for debris (consult a plumber if necessary).
Pressure too high downstreamRegulator set too high; Regulator malfunction.Decrease pressure setting; If problem persists, regulator may need replacement.
Water hammer or fluctuating pressureRapid changes in water demand; Regulator bypass mechanism issue.Ensure proper air chambers are installed in the plumbing system; Consult a plumber for regulator inspection.
Утечки в соединенияхImproperly tightened connections; Insufficient thread sealant.Tighten connections; Reapply thread sealant if necessary (ensure water supply is off first).

8. Технические характеристики

9. Гарантия и поддержка

This Apollo Water Pressure Regulator comes with a manufacturer's warranty. For specific warranty details, please refer to the documentation included with your purchase or contact Apollo customer support.

For technical support or inquiries, please visit the official Apollo webсайте или обратитесь в их отдел обслуживания клиентов.

Связанные документы - 69ELF114TWG

Предварительноview Руководство пользователя электросамоката Apollo Air — настройка, эксплуатация и безопасность
Подробное руководство пользователя электросамоката Apollo Air, включающее настройку, эксплуатацию, правила техники безопасности, обслуживание и гарантийный талон. Узнайте, как безопасно пользоваться Apollo Air.
Предварительноview Руководство пользователя электросамоката Apollo Go
Подробное руководство пользователя электросамоката Apollo Go, охватывающее настройку, эксплуатацию, техническое обслуживание, устранение неисправностей и правила техники безопасности.
Предварительноview Apollo POWER VS Series Turbine Instruction Manual - HVLP Spraying Guide
Comprehensive instruction manual for the Apollo POWER VS Series HVLP Turbine Spray Systems. Learn about setup, operation, maintenance, and best practices for achieving professional spray finishing results.
Предварительноview Руководство пользователя электросамоката Apollo Go
Это руководство пользователя содержит подробные инструкции по электросамокату Apollo Go, включая распаковку, сборку, эксплуатацию, зарядку, техническое обслуживание, правила техники безопасности, устранение неисправностей и гарантийные обязательства. Узнайте, как настроить электросамокат Apollo Go, ездить на нём и ухаживать за ним.
Предварительноview Руководство по сборке и эксплуатации электрического каминного вкладыша Apollo 23G
Подробное руководство по сборке и эксплуатации электрического камина Apollo 23G, включая инструкции по технике безопасности, идентификацию деталей и советы по устранению неполадок для модели HF190108/OLLIEFIR.
Предварительноview Инструкция по установке панели выбора аудиосистемы Apollo SL15
This manual provides detailed installation and operation instructions for the Apollo SL15-series of Audio Selector Panel/Intercom Systems, including the SL15M with internal Marker Beacon. It covers general information, installation procedures, operation, and warranty.