Введение
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your FAAC 400 CBAC EG Swing Gate Opener. Please read this manual thoroughly before proceeding with any installation or operation to ensure proper function and to prevent potential hazards.
Важная информация по безопасности
- Рекомендуется профессиональная установка: Due to the complexity and safety requirements, installation should be performed by qualified personnel.
- Прочитайте все инструкции: Перед установкой или использованием внимательно прочтите и усвойте все инструкции, приведенные в данном руководстве.
- Keep Clear of Moving Gate: Never allow children or pets near the gate area. Keep hands and feet clear of the gate's path during operation.
- Экстренная остановка: Ensure you know how to stop the gate opener in an emergency.
- Электробезопасность: Disconnect power before performing any service or maintenance. All electrical connections must comply with local codes and regulations.
- Регулярный осмотр: Periodically inspect the gate opener and gate for signs of wear, damage, or improper operation.
Продукт болееview и особенности
The FAAC 400 CBAC EG is a versatile hydraulic swing gate operator designed for various applications, from residential to light commercial use. It is engineered for reliable and quiet operation.

Figure 1: The FAAC 400 CBAC EG Swing Gate Opener, a silver-colored hydraulic arm with a black manual release mechanism.
Основные характеристики:
- Гидравлическое управление: Provides smooth and powerful gate movement.
- Hydraulic Lock: Securely locks the gate in both open and closed positions.
- Тихая работа: Designed for low-noise operation.
- Self-Lubricating: Engineered for extended lifespan with minimal maintenance.
- Key-Protected Manual Release: Allows for manual gate operation during power outagЧС или чрезвычайные ситуации.
- Источник питания: Operates on 115VAC.
- Универсальное применение: Suitable for residential and light commercial swing gates up to 16 feet long and 1,300 lbs.
Настройка и установка
The installation of the FAAC 400 CBAC EG Swing Gate Opener requires specialized knowledge and adherence to safety standards. It is strongly recommended that installation be performed by a certified professional.
Общие рекомендации:
- Подготовка места: Ensure the gate structure is sound and capable of supporting the operator's weight and forces. Clear the gate's path of any obstructions.
- Монтаж: Mount the operator securely to the gate post and gate frame according to the detailed instructions provided in the full installation guide (not included in this general manual). Proper alignment is crucial for smooth operation.
- Электрическое подключение: Connect the operator to a dedicated 115VAC power source. All wiring must comply with local electrical codes. Ensure proper grounding.
- Control Unit Integration: If integrating with a control board for a dual gate system or a new installation, follow the control unit's specific wiring diagrams and programming instructions. This operator can be used to convert a single gate kit into a dual master/slave system or as a replacement unit.
- Устройства для обеспечения безопасности: Install all required safety devices, such as photo-electric sensors and safety edges, to prevent entrapment and ensure safe operation.
Refer to the comprehensive installation manual provided with your complete gate opener system for detailed, step-by-step instructions and diagrams.
Инструкция по эксплуатации
Once properly installed and configured, the FAAC 400 CBAC EG Swing Gate Opener operates automatically or via a control device (e.g., remote control, keypad).
Нормальная работа:
- Автоматический цикл: Activate the gate opener using your chosen control device. The gate will open or close smoothly.
- Hydraulic Lock: The integrated hydraulic lock will engage automatically when the gate reaches its fully open or closed position, securing it without the need for additional locking mechanisms.
- Обнаружение препятствий: The system is designed to detect obstructions. If an obstruction is encountered, the gate should stop or reverse. Always ensure the gate path is clear.
Manual Release (Emergency Operation):
In the event of a power failure or system malfunction, the gate can be operated manually using the key-protected release mechanism.
- Locate the manual release mechanism on the operator (refer to Figure 1 for general location).
- Insert the provided key into the lock and turn it to disengage the hydraulic lock.
- Carefully push or pull the gate to open or close it manually.
- To re-engage automatic operation, re-lock the mechanism with the key and ensure power is restored.
Обслуживание
Regular maintenance ensures the longevity and optimal performance of your FAAC 400 CBAC EG Swing Gate Opener. While the unit is self-lubricating, periodic checks are recommended.
- Визуальный осмотр (ежемесячно): Check for any signs of wear, corrosion, or damage to the operator, mounting brackets, and gate hinges. Ensure all fasteners are tight.
- Gate Path Clearance: Regularly clear the gate's path of any debris, vegetation, or obstructions.
- Safety Device Check (Monthly): Test all safety devices (e.g., photo-electric sensors) to ensure they are functioning correctly.
- Профессиональное обслуживание (ежегодно): It is recommended to have a qualified technician perform an annual inspection and service to check hydraulic fluid levels, seals, and overall system health.
- Уборка: Keep the exterior of the operator clean from dirt and grime. Do not use harsh chemicals.
Поиск неисправностей
This section provides basic troubleshooting steps for common issues. For complex problems, contact a qualified technician.
- Ворота не отвечают:
- Check if the power supply to the operator is active.
- Ensure the manual release mechanism is fully engaged (locked).
- Verify that remote controls or other activation devices have working batteries and are within range.
- Inspect safety sensors for obstructions or misalignment.
- Остановка ворот в середине цикла:
- Проверьте наличие физических препятствий на пути ворот.
- Inspect safety sensors for activation or malfunction.
- Ensure the gate moves freely when in manual release mode, indicating no mechanical binding.
- Необычные шумы:
- Perform a visual inspection for loose components or signs of wear.
- Contact a professional technician for diagnosis of internal hydraulic or mechanical issues.
If these steps do not resolve the issue, contact FAAC customer support or a certified service technician.
Технические характеристики
| Модель | 400 CBAC EG |
| Производитель | ФААК |
| Источник питания | 115 В переменного тока |
| Рабочий объемtage | 115 В переменного тока |
| Максимальная длина ворот | 16 футов |
| Макс. вес ворот | 1,300 фунтов |
| Материал | Металл, Нержавеющая сталь |
| Цвет | Серебро |
| Рекомендуемое использование | Residential, Commercial, Industrial, Apartment, Subdivision, Condo |
| Спецификация соответствует | UL |
Гарантия и поддержка
Информация о гарантии:
The FAAC 400 CBAC EG Swing Gate Opener comes with a 3-летняя ограниченная гарантия производителяДанная гарантия распространяется на дефекты материалов и изготовления при условии нормального использования. Сохраните чек о покупке для предъявления гарантийных претензий.
For full details regarding warranty terms, conditions, and exclusions, please refer to the official warranty documentation provided with your product or contact FAAC directly.
Служба поддержки клиентов:
For technical assistance, troubleshooting beyond this manual, or warranty service, please contact FAAC customer support. Have your product model number (400 CBAC EG) and purchase information ready when contacting support.
Contact information for FAAC can typically be found on their official webсайте или в упаковочных материалах.





