ROXX B4-W CLUSTER Red LED
Specifications
- Model: CLUSTER B4 W
- Power cord: EU country specific (if not ordered differently)
- Pre-installed PUK
Product Usage Instructions
Installation & Setup
Physical Installation and Rigging
ROXX CLUSTER B4 W may be installed in any orientation. For this purpose, the product provides several options:
- Standing: The fixture’s Yoke includes two M8 inner threads to install the optional ROXX YOKE FLOOR EXTENSION.
Operation
Start Up
Follow these steps to start up the CLUSTER B4 W:
- Connect the power cord to a power source.
- Press the power button to turn on the device.
Control Display
The control display provides information about the current settings and status of the device.
Display Short Cuts
Use the display shortcuts for quick access to commonly used functions.
Configuration
The configuration settings allow you to customize the operation of the device:
- Set DMX Start Address (Direct Access): Configure the DMX start address for the device.
- Selecting DMX Mode: Choose the desired DMX mode for operation.
- Stand Alone: Operate the device in standalone mode.
- Slave Mode: Set the device to slave mode for synchronization with other units.
- Settings: Access and adjust various settings of the device.
- System Info: View system information and diagnostics.
Troubleshooting
If you encounter any issues with the CLUSTER B4 W, refer to the troubleshooting section of the user manual for solutions.
FAQ
Q: Can I install the CLUSTER B4 W in any orientation?
A: Yes, the product supports installation in various orientations, including standing with the optional YOKE FLOOR EXTENSION.
Q: How do I configure the DMX settings of the device?
A: To configure DMX settings, navigate to the Configuration menu on the control display and follow the on-screen instructions for setting DMX start address and mode.
SAFETY INFORMATION
- General Preventive Measures
- Please read, understand and follow the instructions.
- Store the instructions and information in a safe place.
Best solution is the ring binder provided by ROXX. - Follow all safety warnings. Under no circumstances remove safety warnings or other information from the equipment.
- Don’t use the equipment for any other intended purpose or manner.
- Use only stable and compatible stands and/or brackets. Especially when fix installed.
Make sure the wall brackets are properly installed and safe. Make sure the device is securely installed and cannot fall. - Check the safety regulations applying for your country before and during installation.
- Keep the device away from heat! Don’t place/install near heaters, ovens or any source of heat.
Make sure that the device always is efficiently cooled and cannot overheat. - Always guarantee that ventilation and cooling slots are clean and not blocked.
- Item must be away minimum 20cm from anything around and above it.
- Do not use this device close to water.
- Do not expose this equipment to flammable materials.
- Make sure that no objects can fall into the device.
- Only use this device with the accessories recommended by the manufacturer.
- Always check the equipment for housing damages, so that no water can enter the device.
No containers containing liquids of any kind should be place on top of the unit. - Opening or modifying this device is only allowed by authorized and qualified persons.
- All cables need to be checked after connecting the device in order to prevent damage or accidents.
- Make sure that the device is transported safe and packed proper in order to prevent damage of any kind.
- Once you notice improper function of your device due to damage, electric shock or anything similar,immediately unplug the unit from the mains outlet and contact our service department.
- Clean the device with a dry cloth.
- Observe all disposal laws applicable in your country. Especially for the packaging.
- Plastic bags are not a toy! Keep away from children!
- Please note that changes or modifications which are not approved by the party responsible for compliance will void the user’s authority to operate the device.
- Regulations for equipment that connects to power mains
- If an earthing contact is available in the used power cord, it must used in combination with an power outlet, providing a protective ground. In no circustances should the protective ground be deactivated.
- Do not switch on the device immediately after it has been in strong different temperatures, especially after transport. Let the device acclimatize to the temparature in the room of usage first to prevent moisture and condensation.
- Verify that the correct voltage and frequency are available in the area of operation, before connecting the unit to the mains outlet.
- If the plug doesn‘t fit in your mains outlet, contact your electrician.
- Make sure your power cord/adapter/connector does not show signs of kinks/warps or is being stepped on.
- Allwas disconnect the unit when not in use or being cleaned. Don‘t pull on the cord to disconnect.
Only touch power connections with dry hands! - Don‘t switch the unit on/off rapidly. This may cause damage.
- If a fuse needs to be replaced, ALWAYS make sure that exact the same fuse will be used (type and rating). Repeatedly blown fuses need to be checked by an authorised service technician.
- In the risk of lighting strike all units need to be unpluged from the mains in order to prevent damage.
- During installation there must be a voltage free condition.
- The device needs to be cleaned and serviced regularly and will credit this with a longer life cycle.
Dust, dirt, moist, water, smoke, nicotine or anything similar inside the unit will cause damage/malfunction. - The unit needs to have at least 0,5m distance to anything flammable.
- You have to make sure that any electrical installation applys to the laws of your country.
Correct power cables and applying standards have to be used.
Technical warnsigns and explanation
In order to prevent the risk of an electric shock, under no circumstances remove the cover/back or open the unit in any way! No user serviceable parts are inside. Service, maintenance and repairs should only be done by qualified service personnel or the manufacturer.
Dangerous uninsulated voltage inside the device can cause an electrical shock when opened by unqualified personnel.
Important operating and maintenance instructions apply!
Do not operate this device in tropical climates.
CAUTION! Intense LED light source! Risk of eye damage. Do not look into the light source
The housing surface of the spotlight can heat up to temperatures as high as 70 °C in regular use. Ensure that it is not possible to come into contact with the housing unintentionally. Always allow sufficient time for the lamp to cool down before dismantling, carrying out maintenance work or charging etc..
IMPORTANT INFORMATION!
- This is a product which has been developed for professional usage in event technology. It is not suitable as a houshold lighting.
- NEVER stare, not even temporarily, directly into the light source.
- Don‘t use magnifiers or any other optical instrument to look at the beam.
- The effects of this device, expecially the stroboscope effect, can cause problems for sensitive people or may even cause epileptical seizures.
INTRODUCTION
About us
The name ROXX® came easily.
Combined with the concentrated knowledge and many years of experience, our three founders, who have been leaving their mark in the event and lighting industry for many years already, came together in 2020 to start this outstanding venture.
Product development, sales and marketing as well as the exceptional know-how and the profound rooting in the field of the professional lighting technology belong to our core competences and therefore guarantee extremely in-novative and reliable products, excellent support and professional service in every aspect.
Designed & developed in Germany
ROXX® products are developed and designed in Germany. Always in tight consultation with our customers and experts who will eventually be working with these tools. This ensures innovative, easy-to-use and performance-oriented solutions, which provide added value for our customers.
Made to last
Recommended for permanent outdoor use, most ROXX® products feature additional corrosion protection and enhanced IP66 equipment protection, thereby providing that crucial extra for a wider range of applications. In addition to architectural or theme park applications, even fixed installations in coastal or offshore areas with high salt exposure can be reliably implemented over long periods of time.
CLUSTER B4 W
All CLUSTER products can be easily connected both horizontal and vertically, by using the integrated C-Lok system. The series is made to enable toolless multiple array confi gurations, scalable from a single vertical line, to massive matrix-like arrays. Due IP65 rating all products are outdoor ready and protected from ingress of dust and rain. There are several mounting options – Camlock mounts on top and back enable the use of Omega-Brackets, Yokes can be attached to mounting points on all sides, or the internal C-Lok system can be used for seemless interconnection. Pre-Link Magnets on top and side help to allign the fi xtures, giving an incredible user-friendly operation and save interlocking. A specially designed rigging bracket is used for seemless connection of multiple Blinders, to avoid gaps due to bracing of the truss structure by variable, sliding mounting positions. Floor extensions can be used to create vertical structures in single or double rows.
In the warmwhite versions, an emulated ´shift to warm´ warms the color temperature of the light as it dims. To de-liver a perfect classic tungsten look, Amber and Red LED´s are mixed with the highpower warmwhite LED´s when decaying.
GENERAL PRODUCT INFORMATION
Scope of delivery
- 1x CLUSTER B4 W
- Power cord with plug (EU country-specific, if not ordered differently)
- Pre-installed PUK
We´re offering a wide range of professional accessories (optional). Please see under menu 6 or at our website www.roxxlight.com
Control Functions
- 1CH DWE, 2CH DWE, 4-1CH DWE, 4-2CH DWE, 7CH STROBE, 9CH STANDARD, 12CH EXTENDED 17CH EXTENDED
- RDM (Remote Device Management)
- Stand Alone Functions including auto programs and Quick Light.
- Master & Slave
Features
INSTALLATION & SETUP
Physical Installation and Rigging
ROXX CLUSTER B4 W may be installed in any orientation. For this purpose the product provides several options:
Standing:
The fixtures Yoke includes two M8 inner threads to install the optional ROXX YOKE FLOOR EXTENSION.
Hanging:
The fixture can be installed in different ways:
- Directly by integrated 1/4 turn Camlocks on top- or rear side
- . By included yoke with several mounting points:
Additional Yoke anchor points:
In the delivery state, the yoke is preinstalled in such a way that the individual eyes can be rotated +/-20° in the pan. Each CLUSTER device also provides side anchor points for the yoke so that the device can then be rotated either clockwise or counterclockwise so that the individual eyes can then be adjusted +/-20° in tilt movement.
In addition, the B4 W and B4 FC models offer a third, lower anchor point that can be used to mount the optional YOKE 4.3 to optimize the center of gravity on, for example, a 6-lite or 8-lite.
Attention!
This should only be used when clustering several units together, as otherwise the center of gravity of the individual unit is no longer in the middle and the unit can unintentionally tip over when the yoke is released. - Using optional ROXX RIGGING BRACKET
For seemless connection of multiple Blinders, to avoid gaps due to bracing of the truss structure by variable, sliding mounting positions.
Product Clustering
All CLUSTER products can be easily connected both horizontal and vertically, by using the integrated C-Lok system. The series is made to enable toolless multiple array configurations, scalable from a single vertical line, to massive matrix like arrays.
To connect the devices with each other, proceed as follows in sequence:
- Bring the devices together with the respective top and bottom side.
A so-called centering puk is pre-installed on the top of every cluster device.
This should always be installed when connecting the de-vices to each other. - Pre-Link Magnets on top and side help to allign the fix-tures due cluster process and giving support operation for convenient and save interlocking.
Important Note:
Even though the pre-link magnet system is strong enough to hold the devices to-gether, at least one hand must always remain on the device for support during the connection. - Make sure that the C-Lok hooks are turned counterc-lockwise (CCW) to the end-position first before you finally lock the C-Loks.
- For locking all C-Lok´s, please turn them clockwise into end-position.
Note:
As soon as both dot indicators are in line, the C-Lok is securely locked
Maximum Tensile and Torsion Load
Before setting up Cluster configurations, be aware of the maximum tensile and torsion load, listed here below. Also make sure the mounting clamps are capable of supporting the total weight of your configuration.
The different rigging options of all Cluster products result in different maximum tensile and torsion loads that must not be exceeded for a safe overhead installation.
The maximum loads listed here below take into account the 10-fold safety!
- Rigging by integrated 1/4 turn Camlocks on top- or rear side
- Rigging by Yoke with multiple mounting points
- Using optional ROXX RIGGING BRACKET with 2x Mounting Clamps
Important Note:
Please be aware of using the centering PUK for safe RIGGING BRACKET installation to the CLUSTER device.
Connections*
- A: Mains In: IP65 Power input connector with rubber sealing cap.Connect using the provided power cable (when not in use, always close with rubber sealing cap).
- B: Mains Out: IP65 Power output connector with rubber sealing cap. Provides power to additional fixtures. Ensure that the to-tal power consumption of all daisy-chained devices connec-ted do not exceed 8A (Ampere)! (when not in use, always close with rubber sealing cap).
- C: DMX IN: Male IP65 5-pin XLR connector (when not in use, always close with rubber sealing cap).
- D: DMX OUT: Female IP65 5-pin XLR connector when not in use, always close with rubber sealing cap).
- E: GoreTex
- F: Safety Eyelet
- G: IP65 USB port for firmware updates
Note:
In order to provide protection from spraying water, in accordance with protection class IP65, special IP65-rated XLR connectors must be used correctly with the DMX input and output sockets, or they must be closed using the rubber sealing caps. When connected correctly, or when sealed correctly with the rubber sealing caps, the POWER IN and POWER OUT sockets are protected from spraying water, as in accordance with IP65.
AC Power
The CLUSTER B4 W operates on any 100–260 V, 50/60 Hz AC mains power supply with a maximum power con-sumption of 220W.
Connect the fixture to AC power using the supplied cable or a similar one with Neutrik powerCON TRUE1 NAC3FX-W or a compatible type, to ensure the correct ingress protection (IP).
For temporary installations, the mains cable must be fitted with a grounded connector intended for exterior use. The fixture must be grounded/earthed and be able to be isolated from AC power. The AC power supply must incorporate a fuse or circuit breaker for fault protection.
Wire Color (EU models) | Wire Color (US models) | Conductor | Symbol |
Brown | Black | Live | L |
Blue | White | Neutral | N |
Yellow / Green | Green | Ground (earth) | ![]() |
Warning!
Read “Safety Informations” starting on page 3 before connecting the fixtures to AC mains power!Do not connect the fixture to an electrical dimmer system, as doing so may cause damage that is not covered by the product warranty!
DMX Connection
The CLUSTER B4 W is fully controllable by DMX (USITT DMX512-A standard, based on RS-485) and RDM.
Cable Connection
If using a cabled DMX system, connect the DMX IN cable to the input connector (male 5-pin XLR connector) and
DMX OUT cable to the output (female 5-pin XLR connectors).
For outdoor installations, use only IP65-rated XLR connectors.
Use shielded twisted pair cable designed for RS-485 devices. The cables are daisy chained between the fixtures,and up to 32 fixtures can be connected to the same DMX link. Up to 300 meters (1000ft.) of cable is achievable with high quality DMX cables. All DMX links must be terminated in the last fixture by connecting a DMX termination plug to the last fixture’s 5 pin DMX out connector.
Standard microphone cable is not suitable for transmitting DMX.
OPERATION
Start up*
Once the fixture is connected to AC power, the boot process starts and the following information will appear on the display:
“Ready to ROXX”, the product name and the current software version.
After this process, the fixture is ready for operation, and starts in the previously enabled mode.
Note:
During boot process the fan spins up quickly to blow out some possible dust from last use.
Control Display*
OLED Display with Touch-Sensitive controls
Press ENTER to access the selection menu for system settings or confirm changes.
Press ESC to take a step back in the menu.
Press arrows to scroll up and down inside the menu and change values, such as DMX address.
Note:
For a smooth navigation thru the menu settings, please make sure the display surface is dry and dust free.
After approximately 1 minute of inactivity inside the menu settings, the display will automatically jump back to home screen.
Display Short Cuts*
Short Cuts
For some always recurring functions the fixture allows quick and user-friendly access at home screen over some display control short-cuts:
User Reset or Factory Reset*
Pressing ESC+ENTER simultaneously a Factory Reset or User Reset can be started.
By using the up/down arrows the Factory- or User Reset can be selected.
For confirming press ENTER, to jump back please press ESC.
Note:
After Factory Reset all fixture settings are set back to factory default values.
After User Reset all user selected reset functions and user default values will set back.
Also a short self-test will start immediately while dimming in and out each single color.
Display Off
Pressing ESC + arrow down simultaneously the display backlight function will set to off and the display will turn off immediately. Once a control is pressed the display backlight will turn on.
Manual display flip function*
The fixture includes an auto display flip function by default.
To use the manual display flip function please disable the auto flip function under Settings / Display first. Once the auto display flip function is disabled you can use the manual display flip function by pressing arrow up + arrow down simultaneously. The display will rotate 180. By pressing both arrows simultaneously again the display will flip back.
Note:
Once the display is flipped both Up / Down controls will work according to the display rotation.
Quick Light function
(hold 3 seconds)
For easy and fast operation during setting the lights the fixture includes a user-friendly Quick Light function. If DMX is not assigned please press and hold ENTER for 3 seconds at homescreen, after the Quick Light function will appear. Here dimmer can be adjusted from 0-100% by using up/down arrows, to take over the dimming value please press ENTER to confirm.
Configuration
Home Screen
After boot process the fixture is ready for operation and starts in the previously enabled mode. At home screen the following information will appear, depending on the current operating mode:
- A DMX Adress
- B Operating Mode (DMX Mode, Quick Light or Standalone Mode)
- C Next available DMX address depending on the fixtures DMX footprint
- D External Data protocol (DMX).
- E The dot indicates the active protocol
Set DMX Start Address (Direct Access)
At Home Screen the DMX address can be changed directly by using the up and down arrows. During this process the DMX address starts blinking, once it´s confirmed by pressing ENTER it stops blinking.
If the DMX address will not be confirmed by ENTER within 10 seconds, the display will jump back and show the DMX address from before and stops blinking.
Selecting DMX Mode*
At home screen please press ENTER to access to the main menu (level 1).
While using UP / DOWN arrows, please select the menu item “DMX Mode” and confirm by pressing ENTER.
In the following sub-menu (level 2), you can now choose between 8 different DMX operating modes while using the UP/Down arrows and confirm by pressing ENTER or jump back by pressing ESC.
After confirmation the display will jump back to main menu (level 1). Press ESC for homescreen, here the selected DMX mode will be displayed.
Note:
For detailed information about the several DMX modes including channel assignment please see our DMX Control chart.
Stand Alone*
Press ENTER to access to main menu (level 1).
While using the UP / DOWN arrows, please select the menu item “Stand Alone” and confirm by pressing ENTER.
In the following sub-menu (level 2), you can now choose between 2 different Stand Alone operating modes (Auto, Quick Light), Stop Stand Alone while using the UP/Down arrows and confirm by pressing ENTER or jump back by pressing ESC.
To finally use Stand Alone programs please make sure DMX is disconnected to the fixture, as this protocol has priority.
Stop Stand Alone
To stop a running Stand Alone mode immediately, please select “Stop Stand Alone” and confirm by pressing ENTER. The display will automatically jump back to level 1.
Auto*
Select “Auto” by using the up/down arrows and press ENTER.
Here at sub-menu (level 3), you can choose between 5 different Auto Effects (Effect 1 – 5) and Stop Program. Using the Up/Down arrows you can select one of the 5 Effects and confirm by pressing ENTER or step back by ESC. After confirming your preferred Effect, you can now adjust speed and brightness at level 4.
To adjust speed, please use the UP / DOWN arrows to select the menu item “Speed”, and confirm with ENTER. After use UP / DOWN arrows to adjust the speed value between 000-100 and confirm by ENTER or jump back by ESC. To adjust brightness please select “Dim” as per the procedure previously described and confirm with ENTER. After use UP / DOWN arrows again to adjust the brightness value between 000-100 and confirm by ENTER or jump back by ESC.
Once it´s confirmed or denied the display will automatically jump back to level 3.
To stop running a selected Effect please chose “Stop Program” at level 3 or “Stop Stand Alone” at level 2. For returning back to homescreen please press ESC three times.
At homescreen the selected Stand Alone mode “Auto” and the selected program will be displayed.
Note:
Using arrows UP /DOWN at homescreen Auto programs can be directly changed according to the list.
Quick Light*
The standalone mode “Quick Light” allows a direct adjustment of the single eyes brightness and dimmer and shutter.
To adjust your Quick Light please press ENTER to access to main menu (level 1).
While using the UP / DOWN arrows select the menu item “Stand Alone” and confirm
by pressing ENTER. After please select the item “QuickLight” by using the up/down arrows and press ENTER again. Using UP and DOWN controls, select your desired color and confirm with ENTER.
After you can adjust the brightness for each eye between 000-255 and confirm by ENTER.
Besides the individual color mix also a master dimmer can be adjusted between 000-100.
For strobe effects please adjust the Shutter value between 000-255.
Note: Please see detailed explanation for strobe effects inside DMX chart at the end of this manual. Using UP/DOWN arrows at homescreen you can change Quick Light dimmer value.
Slave Mode*
Slave Mode allows same model fixtures to be controlled by the “Master” fixture via DMX). The “Master” device should run in Stand Alone mode, all “Slave” devices should set to “Slave”.
To select “Slave” please press ENTER to access to main menu (level 1).
While using the UP / DOWN arrows, please select the menu item “Slave” and confirm by pressing ENTER. Now this unit is set to “Slave”. Please connect the slave and the master devices (same model) with a DMX cable and enable one of your preferred standalone mode on the master device. Once the Stand Alone mode is activated all slave devices will follow the master device.
Note: All devices should use same software version.
Once Stand Alone mode is disabled at Master unit the display of Slave unit starts to blink.
Settings
Main Menu | Menu level 2 | Menu level 3 | Menu level 4 | Description | |
Settings Settings |
Display |
Display Flip |
<on/off> |
On= Flip control panel display by 180° (e.g. for overhead installation) Off= normal control panel display | |
Backlight |
<on/off> |
On= controls permanent on, display itself will deactivate after 60 minues of incativity
Off= controls and display deactivation after approximately 1 minute of inactivity |
|||
Auto Lock |
<on/off> |
On= Automatically locks the controls after approximately 1 minute of inactivity. After attempted input the display shows: „Locked!“ Unlock process: press arrows up, down, up, down consecutively | |||
Startup Mode (using last adjust- ments of specific Standalone Modes) | DMX |
Select your default operating mode when fixture is powered on |
|||
Auto | |||||
Quick Light | |||||
DMX Fail |
Hold | Hold= last command retains | |||
Blackout | Blackout= Activates Blackout | ||||
Emergency Light | Emergency Light= Fixtures changes to full on | ||||
Dimmer Curve |
Linear | Linear= Light intensity increases linear with DMX value | |||
Exponential |
Exponential= Light intensity can be set more smooth at lower DMX values and broadly at higher DMX values. | ||||
Logarithmic |
Light intensity can be broadly adjusted at lower DMX values and more smooth
at higher DMX values |
||||
S-Curve |
Light intensity can be adjusted smoothly at lower and higher DMX values and broadly at medium DMX values | ||||
Dimmer Response |
LED | The LED responds abruptly to it´s DMX values | |||
Medium | The LED responds with medium delay to DMX value changes at brightness | ||||
Halogen | The LED responds similar to a halogen fixture with soft changes at brightness. | ||||
Redshift |
On / Off |
On= Activates Redshift, Off= Deactivates Reds- hift | Redshift function simulate traditional halogen fixtures while dimming down. Redshift affects only between 2700-3500K. | ||
RAW Balance (affects RAW Mode in DMX and Stand Alone Modes |
RAW | W,A,R with maximum value of brightness | |||
User Calibration |
White 1 | <0-255> |
individual color calibration of W,A,R for each single eye |
||
Amber 1 <0-255> | |||||
Red 1 | <0-255> | ||||
White 2 | <0-255> | ||||
Amber 2 <0-255> | |||||
Red 2 | <0-255> | ||||
White 3 | <0-255> | ||||
Amber 3 <0-255> | |||||
Red 3 | <0-255> | ||||
White 4 | <0-255> | ||||
Amber 4 <0-255> | |||||
Red 4 | <0-255> |
LED Frequency |
800 Hz |
Select preferred LED PWM frequency |
||
1200 Hz | ||||
2000 Hz | ||||
3600 Hz | ||||
12000 Hz | ||||
25000 Hz | ||||
Fan |
Auto | Adjust fan speed relative to internal fixture temperature | ||
Silent | Low fan speed for silent operation | |||
Fan Off | Fan Off | |||
Max. Power | High fan speed for maximum cooling effect | |||
Invert Mapping |
Off | No Pixel Invert | ||
CW | Inverts the Pixel Layout clockwise, Pixel #3 becomes Pixel #1 | |||
CCW | Inverts the Pixel Layout counter-clockwise, Pixel #2 becomes Pixel #1 | |||
Transfer Configuration |
Including DMX Address | Transfer the same menu settings of this fixture to all the other in daisy chain (same model), either with DMX address or without. After power off and on again, the transfered settings should stay the same. | ||
Without DMX Address |
||||
LED Mode |
Illumination | Normal output for constant illumination | ||
Boost | Boost for temporarily highest output for blinder and strobe effects | |||
USB Update |
Yes | Run firmware update via USB port | ||
No | Do not run firmware update via USB port | |||
Factory / User Reset |
Factory Reset |
Are you sure to reset? Confirm by pressing ENTER, cancel with ESC | Restores all factory defaults including User Colors, but no User defaults. | |
User Reset |
Are you sure to reset? Confirm by pressing ENTER, cancel with ESC | Restores all User Reset according to the User Preset List. Timer Function and DMX adress restore to Factory default. Once User Reset is activated a fixture self test will start. |
Main Menu | Menu level 2 | Menu level 3 | Menu level 4 | Menu Level 5 | Description |
Settings |
Factory / User Reset |
User Reset List |
1CH DWE, 2CH DWE, 4-1CH DWE, 4-2CH DWE, 7CH STROBE, 9CH STANDARD, 12CH EXTENDED, 17CH EX- TENDED |
Select your User Reset defaults |
|
Display Flip | <on/off> | ||||
Backlight | <on/off> | ||||
Auto Lock | <on/off> | ||||
Startup Mode | <DMX/Auto, Quick Light> | ||||
DMX Fail | <Hold/Blackout/Emergency (Light)> | ||||
Dimmer Curve | <Linear, Exponential, Logarithmic, S-Curve> | ||||
Dimmer Response | <LED, Medium, Halogen> | ||||
Redshift | <on/off> | ||||
LED Frequency | <800Hz, 1200Hz, 2000Hz, 3600Hz, 12000Hz, 25000Hz> | ||||
RAW Balance | RAW / User Calibration | ||||
Fan | <Auto, Silent, Studio, Fan Off, Max. Power> | ||||
Invert Mapping | <off, CW, CCW> | ||||
Transfer Configuration | <including DMX address /
without DMXaddress> |
||||
LED Mode | <Illumination, Boost> | ||||
USB Update | <yes/no> |
Pixel Arrangement
Dimmer Curves
System Info
Main Menu | Menu level 2 | Menu level 3 | Menu level 4 |
System Info |
Firmware Version | vx.xx | Display installed firmware version |
Serial Number | 201xxxxxxxx | ||
RDM UID | 0X6a6axxxxxxxx | Display unique RDM ID for identification | |
Temperatures |
LED 1: Celsius/Fahrenheit : XXX°C / XXX °F LED 2: Celsius/Fahrenheit : XXX°C / XXX °F LED 3: Celsius/Fahrenheit : XXX°C / XXX °F LED 4: Celsius/Fahrenheit : XXX°C / XXX °F |
Display LED 1-4 temperature by celsius and fahrenheit |
|
Power on Time |
Total:
LED 1: xxxxxhours LED 2: xxxxxhours LED 3: xxxxxhours LED 4: xxxxxhours |
Display fixture total power on time |
|
LED on Time | Total: xxxxxhours | Display LED 1-4 total power on time | |
Errors | Errors information | Display error codes |
ACCESSORIES
TECHNICAL DATA / DIAGRAMS
Technical drawings and measurements
IP Rating
ROXX products conform to officially classified IP standard levels. CLUSTER B4 W is rated to IP65 when using the co-vers for the housing parts. IP stands for Ingress Protection and IP65, according to classified standard, means shielded against dust and high-pressure jets of water from any side.
Ingress Protection
Technical Data
Photometrics | |
LED expected lifetime | 50.000 hours |
Lightsource | 4x 300W Warm-White + Amber + Red |
Type of optical system | Reflector with Compound Eye Lens |
LED PWM Frequency | selectable 800Hz, 1.200Hz, 2.000Hz, 3.600Hz, 12kHz, 25kHz |
Beam angles (50%) | 50° |
Maximum Field angles (10%) | 87° |
Color temperature range | 2.900K |
Efficancy (max) | 25,19 lm/W |
CRI/RA | 80 |
Luminous flux | 34.000 lm |
illuminance Lux @ 1m / 3,3ft | 37870lx / 3518fcd |
illuminance Lux @ 3m / 9,8ft | 4295lx / 399fcd |
illuminance Lux @ 5m / 16,4ft | 1535lx / 143fcd |
illuminance Lux @ 7m / 23,0ft | 795lx / 74fcd |
illuminance Lux @ 10m / 32,8ft | 395lx / 37fcd |
Thermal Characteristics | |
Cooling | Active, Forced Air, Temperature-regulated |
Humidity (max.) | 95% |
Temperature range, Operating | -40°C to 45°C |
Temperature range, Start-up | -20°C to 45°C |
Temperature range, Storage | -40°C to 80°C |
Thermal Protection | Automatic overtemperature protection |
Electrical Data | |
AC Power, max | 90 – 285V 50/60Hz |
AC Power, nominal | 100 – 240V 50/60Hz |
Electrical protection | Overload protection with automatic recover |
Max power consumption (Boost Mode) | 1350W |
Constant power consumption (Illumination Mode) | 440W |
Power Max. Out | 9A @ 230V / 2A @ 120V |
Power Linking @ Max Power Consumption (Boost Mode) | 1 unit @ 230V / 0 unit @ 120V |
Power Linking @ Constant Power Consumption (Illumination Mode) | 7 units @ 230V / 2 units @ 120V |
Power Factor | 0.944 PF (230V) / 0.998 PF (120V) |
Power Supply Unit | Inbuilt auto-ranging electronic switch-mode |
Operator & Controller | |
DMX Functions | Master Dimmer, Master Dimmer Fine, Shutter, Duration, Dimmer 1-4, Dimmer 1-4 Fine, Dimmer Curve, Dimmer Response, Redshift, Effect, Device Settings |
DMX channels | 1CH DWE, 4-1CH DWE, 4-2CH DWE, 7CH STROBE, 9CH STANDARD (default),
12CH EXTENDED, 17CH EXTENDED |
DMX modes | 18 |
Protocol | USITT DMX512A, RDM ANSI E1.20 |
Setting and addressing | OLED graphical display / 4 controls, RDM ANSI E1.20 |
Standalone mode | Auto Program, Quick Light |
Wireless DMX | n.a. |
Indicator | OLED graphical display |
Controls | 4 touch sensitive, backlighted controls |
Strobe | 0-20Hz |
DMX I/O | IP65 XLR 5-pin male/female |
Power In | TRUE1 compatible input & link-thru sockets |
USB Firmware Update | IP65 USB socket |
Dimensions & Weight | |
IP class | IP65 |
IK class | IK08 |
Body material | Aluminum, Nylon |
Lens material | Tempered glass front |
Net dimensions (w x h x d) | 400 x 400 x 191mm |
Net dimensions inches | 15,75 x 15,75 x 7,52 inches |
Net weight (incl. Yoke) | 16,2 kg (35,71lbs) |
Tilt | 360° |
Tilt Locking System | Locking system with toothing and angle indicator |
Included / Optional | |
Included items | Yoke 4.2, 2m Power Cable, Puk |
Optional Accessories | Yoke 4.3, Yoke Floor Extension, Rigging Bracket, Omega Bracket ST |
Color options | Black – RAL 9004 (Standard) Custom color – any RAL (on request) |
Installation | |
Mounting point by Yoke (included) |
3x 13mm / 1/2″ holes, 1x centric TV Spigot attachement, 3x integrated Camlocks for Omega Brackets |
Mounting point on fixture | 1/4 turn Omega Bracket on top and rear side |
Mounting point with otional Rigging Bracket | 2x 13mm / 1/2″ holes for Clamp fixation |
Orientation | Any |
Rigging possibilities | Hanging or ceiling / pendant mount |
Safety features | 2x rear mount for safety wire |
Minimum distance from flammable materials | 0,3 meters (11,8 inch) |
DMX-Charts
CH | 1CH DWE | 2CH DWE | 4-1CH DWE | 4-2CH DWE |
1 | Dimmer | Dimmer 1 | Dimmer 1 | Dimmer |
2 | Dimmer 2 | Dimmer 2 | Dimmer Curve | |
3 | Dimmer 3 | Dimmer Response | ||
4 | Dimmer 4 | Redshift |
CH | 7CH STROBE | 9CH STA
NDARD (default) |
12CH EXTENDED – 8bit | 17CH EXTENDED – 16bit |
1 | Master Dimmer | Master Dimmer | Master Dimmer | Master Dimmer |
2 | Shutter | Shutter | Shutter | Master Dimmer Fine |
3 | Duration | Dimmer 1 | Duration | Shutter |
4 | Dimmer 1 | Dimmer 2 | Dimmer 1 | Duration |
5 | Dimmer 2 | Dimmer 3 | Dimmer 2 | Dimmer 1 |
6 | Dimmer 3 | Dimmer 4 | Dimmer 3 | Dimmer 1 Fine |
7 | Dimmer 4 | Dimmer Curve | Dimmer 4 | Dimmer 2 |
8 | Dimmer Response | Dimmer Curve | Dimmer 2 Fine | |
9 | Redshift | Dimmer Response | Dimmer 3 | |
10 | Redshift | Dimmer 3 Fine | ||
11 | Effect | Dimmer 4 | ||
12 | Device Settings | Dimmer 4 Fine | ||
13 | Dimmer Curve | |||
14 | Dimmer Response | |||
15 | Redshift | |||
16 | Effect | |||
17 | Device Settings |
1CH DWE
CH | Function | Value | Setting | Remark | Default |
1 | Dimmer | 000-255 | 0 – 100% | 0 |
2CH DWE
CH | Function | Value | Setting | Remark | Default |
1 | Dimmer 1
(affects eye 1 + 3) |
000-255 | 0 – 100% | 0 | |
2 | Dimmer 1
(affects eye 2 + 4) |
000-255 | 0 – 100% | 0 |
4-1CH DWE
CH | Function | Value | Setting | Remark | Default |
1 | Dimmer 1 | 000-255 | 0 – 100% | 0 | |
2 | Dimmer 2 | 000-255 | 0 – 100% | 0 | |
3 | Dimmer 3 | 000-255 | 0 – 100% | 0 | |
4 | Dimmer 4 | 000-255 | 0 – 100% | 0 |
4-2CH DWE
4-2CH DWE | |||||
CH | Function | Value | Setting | Remark | Default |
1 | Dimmer | 000-255 | 0 – 100% | 0 | |
2 |
Dimmer Curve |
000-51 | No Function – Current Preset from Menu Settings |
0 |
|
052-101 | Linear Dimmer Curve | ||||
102-152 | Exponential Dimmer Curve | ||||
153-203 | Logarithmic Dimmer Curve | ||||
204-255 | S-Curve Dimmer Curve | ||||
3 |
Dimmer Response |
000-063 | No Function – Current Preset from Menu Settings |
0 |
|
064-127 | LED / fast | ||||
128-191 | Medium | ||||
192-255 | Halogen / slow | ||||
4 |
Redshift |
000-84 | No Function – Current Preset from Menu Settings |
0 |
|
085-170 | Redshift Off | ||||
171-255 | Redshift On |
7CH STROBE MODE
7CH STROBE MODE | |||||
CH | Function | Value | Setting | Remark | Default |
1 | Master Dimmer | 000-255 | 0 – 100% | 0 | |
2 |
Shutter |
000 – 019 | Shutter close |
20 |
|
020 – 024 | Shutter open | ||||
025 – 064 | Strobe 1 (fast slow) | ||||
065 – 069 | Shutter open |
2 |
Shutter |
070 – 084 | Strobe 2: opening pulse(fast slow) |
20 |
|
085 – 089 | Shutter open | ||||
090 – 104 | Strobe 3: closing pulse(fast slow) | ||||
105 – 109 | Shutter open | ||||
110 – 124 | Strobe 4: random strobe (fast slow) | ||||
125 – 129 | Shutter open | ||||
130 – 144 | Strobe 5: random opening pulse (fast slow) | ||||
145 – 149 | Shutter open | ||||
150 – 164 | Strobe 6: random closing pulse (fast slow) | ||||
165 – 169 | Shutter open | ||||
170 – 184 | Strobe 7: burst pulse (fast slow) | ||||
185 – 189 | Shutter open | ||||
190 – 204 | Strobe 8: random burst pulse (fast slow) | ||||
205 – 209 | Shutter open | ||||
210 – 224 | Strobe 9: sine wave (fast slow) | ||||
225 – 229 | Shutter open | ||||
230 – 244 | Strobe 10: burst (fast slow) | ||||
245 – 255 | Shutter open | ||||
3 |
Duration |
000-255 |
0 – 100% (0ms – 510ms) |
only affects to channel 2 – Strobe 1
025-064 |
0 |
4 | Dimmer 1 | 000-255 | 0 – 100% | 255 | |
5 | Dimmer 2 | 000-255 | 0 – 100% | 255 | |
6 | Dimmer 3 | 000-255 | 0 – 100% | 255 | |
7 | Dimmer 4 | 000-255 | 0 – 100% | 255 |
9CH STANDARD – 8bit (default)
9CH STANDARD – 8bit (default) | |||||
CH | Function | Value | Setting | Remark | Default |
1 | Master Dimmer | 000-255 | 0 – 100% | 0 | |
2 |
Shutter |
000 – 019 | Shutter close |
20 |
|
020 – 024 | Shutter open | ||||
025 – 064 | Strobe 1 (fast-slow) | ||||
065 – 069 | Shutter open | ||||
070 – 084 | Strobe 2: opening pulse (fast-slow) | ||||
085 – 089 | Shutter open | ||||
090 – 104 | Strobe 3: closing pulse (fast-slow) | ||||
105 – 109 | Shutter open | ||||
110 – 124 | Strobe 4: random strobe (fast-slow) | ||||
125 – 129 | Shutter open | ||||
130 – 144 | Strobe 5: random opening pulse (fast slow) |
2 |
Shutter |
145 – 149 | Shutter open |
20 |
|
150 – 164 | Strobe 6:random closing pulse (fast slow) | ||||
165 – 169 | Shutter open | ||||
170 – 184 | Strobe 7: burst pulse (fast slow) | ||||
185 – 189 | Shutter open | ||||
190 – 204 | Strobe 8: random burst pulse (fast-slow) | ||||
205 – 209 | Shutter open | ||||
210 – 224 | Strobe 9:sine wave (fast-slow) | ||||
225 – 229 | Shutter open | ||||
230 – 244 | Strobe 10: burst (fast-slow) | ||||
245 – 255 | Shutter open | ||||
3 | Dimmer 1 | 000-255 | 0 – 100% | 255 | |
4 | Dimmer 2 | 000-255 | 0 – 100% | 255 | |
5 | Dimmer 3 | 000-255 | 0 – 100% | 255 | |
6 | Dimmer 4 | 000-255 | 0 – 100% | 255 | |
7 |
Dimmer Curve |
000-51 | No Function – Current Preset from Menu Settings |
0 |
|
052-101 | Linear Dimmer Curve | ||||
102-152 | Exponential Dimmer Curve | ||||
153-203 | Logarithmic Dimmer Curve | ||||
204-255 | S-Curve Dimmer Curve | ||||
8 |
Dimmer Response |
000-063 | No Function – Current Preset from Menu Settings |
0 |
|
064-127 | LED / fast | ||||
128-191 | Medium | ||||
192-255 | Halogen / slow | ||||
9 |
Redshift |
000-84 | No Function – Current Preset from Menu Settings |
0 |
|
085-170 | Redshift Off | ||||
171-255 | Redshift On |
12CH EXTENDED
12CH EXTENDED | |||||
CH | Function | Value | Setting | Remark | Default |
1 | Master Dimmer | 000-255 | 0 – 100% | 0 | |
2 |
Shutter |
000 – 019 | Shutter close |
20 |
|
020 – 024 | Shutter open | ||||
025 – 064 | Strobe 1 (fast-slow) | ||||
065 – 069 | Shutter open | ||||
070 – 084 | Strobe 2: opening pulse (fast-slow) | ||||
085 – 089 | Shutter open | ||||
090 – 104 | Strobe 3: closing pulse (fast-slow) | ||||
105 – 109 | Shutter open |
2 |
Shutter |
110 – 124 | Strobe 4: random strobe (fast slow) |
20 |
|
125 – 129 | Shutter open | ||||
130 – 144 | Strobe 5: random opening pulse (fast slow) | ||||
145 – 149 | Shutter open | ||||
150 – 164 | Strobe 6: random closing pulse (fast slow) | ||||
165 – 169 | Shutter open | ||||
170 – 184 | Strobe 7: burst pulse (fast slow) | ||||
185 – 189 | Shutter open | ||||
190 – 204 | Strobe 8: random burst pulse (fast slow) | ||||
205 – 209 | Shutter open | ||||
210 – 224 | Strobe 9: sine wave (fast slow) | ||||
225 – 229 | Shutter open | ||||
230 – 244 | Strobe 10: burst (fast slow) | ||||
245 – 255 | Shutter open | ||||
3 |
Duration |
000-255 |
0 – 100% (0ms – 510ms) |
only affects to channel 2 – Strobe 1
025-064 |
0 |
4 | Dimmer 1 | 000-255 | 0 – 100% | 255 | |
5 | Dimmer 2 | 000-255 | 0 – 100% | 255 | |
6 | Dimmer 3 | 000-255 | 0 – 100% | 255 | |
7 | Dimmer 4 | 000-255 | 0 – 100% | 255 | |
8 |
Dimmer Curve |
000-51 | No Function – Current Preset from Menu Settings |
0 |
|
052-101 | Linear Dimmer Curve | ||||
102-152 | Exponential Dimmer Curve | ||||
153-203 | Logarithmic Dimmer Curve | ||||
204-255 | S-Curve Dimmer Curve | ||||
9 |
Dimmer Response |
000-063 | No Function – Current Preset from Menu Settings |
0 |
|
064-127 | LED / fast | ||||
128-191 | Medium | ||||
192-255 | Halogen / slow | ||||
10 |
Redshift |
000-84 | No Function – Current Preset from Menu Settings |
0 |
|
085-170 | Redshift Off | ||||
171-255 | Redshift On | ||||
11 |
Effect |
000-40 | No Function |
0 |
|
041-083 | Effect 1 (slow to fast) | ||||
084-126 | Effect 2 (slow to fast) | ||||
127-169 | Effect 3 (slow to fast) | ||||
170-212 | Effect 4 (slow to fast) | ||||
213-255 | Effect 5 (slow to fast) |
12 |
Device Settings (please see remark *1) |
000-029 | No function |
0 |
|
030-034 | Display Backlight On (hold 3s) | ||||
035-039 | Display Backlight Off (hold 3s) | ||||
040-044 | No function | ||||
045-049 | DMX Fail Blackout (hold 3s) | ||||
050-054 | DMX Fail Hold (hold 3s) | ||||
055-059 | DMX Fail – Emergency Light (hold 3s) | ||||
060-064 | No function | ||||
65-069 | RAW (hold 3s) | ||||
070-074 | User Calibrated (hold 3s) | ||||
075-079 | No function | ||||
080-084 | LED Frequency 800Hz (hold 3s) | ||||
085-089 | LED Frequency 1200Hz (hold 3s) | ||||
090-094 | LED Frequency 2000Hz (hold 3s) | ||||
095-099 | LED Frequency 3600Hz (hold 3s) | ||||
100-104 | LED Frequency 12kHz (hold 3s) | ||||
105-109 | LED Frequency 25kHz (hold 3s) | ||||
110-114 | No function | ||||
115-119 | Fan Auto (hold 3s) | ||||
120-124 | Fan Silent (hold 3s) | ||||
125-129 | Fan Off (hold 3s) | ||||
130-134 | Fan High Power (hold 3s) | ||||
135-139 | No function | ||||
140-144 | Invert Mapping Off (hold 3s) | ||||
145-149 | Invert Mapping CW (hold 3s) | ||||
150-154 | Invert Mapping CCW (hold 3s) | ||||
155-159 | No function | ||||
160-164 | LED Mode – Illumination (hold 1,5s) | ||||
165-169 | LED Mode – Boost (hold 1,5s) | ||||
170-174 | No function | ||||
175-179 |
Factory Reset (hold 3s) |
Reset only starts if Shutter channel is set to DMX 250 | |||
180-184 |
User Reset (hold 3s) |
Reset only starts if Shutter channel is set to DMX 250 / no self-test by DMX | |||
185-255 | No function |
17CH EXTENDED
17CH EXTENDED | |||||
CH | Function | Value | Setting | Remark | Default |
1 | Master Dimmer | 000-255 | 0 – 100% | 0 | |
2 | Master Dimmer Fine | 000-255 | 0 – 100% | 0 |
3 |
Shutter |
000 – 019 | Shutter close |
20 |
|
020 – 024 | Shutter open | ||||
025 – 064 | Strobe 1 (fast slow) | ||||
065 – 069 | Shutter open | ||||
070 – 084 | Strobe 2: opening pulse (fast slow) | ||||
085 – 089 | Shutter open | ||||
090 – 104 | Strobe 3: closing pulse(fast slow) | ||||
105 – 109 | Shutter open | ||||
110 – 124 | Strobe 4: random strobe(fast slow) | ||||
125 – 129 | Shutter open | ||||
130 – 144 | Strobe 5: random opening pulse (fast slow) | ||||
145 – 149 | Shutter open | ||||
150 – 164 | Strobe 6:random closing pulse (fast slow) | ||||
165 – 169 | Shutter open | ||||
170 – 184 | Strobe 7: burst pulse (fast slow) | ||||
185 – 189 | Shutter open | ||||
190 – 204 | Strobe 8: random burst pulse (fast slow) | ||||
205 – 209 | Shutter open | ||||
210 – 224 | Strobe 9:sine wave (fast slow) | ||||
225 – 229 | Shutter open | ||||
230 – 244 | Strobe 10: burst (fast slow) | ||||
245 – 255 | Shutter open | ||||
4 |
Duration |
000-255 |
0 – 100% (0ms – 510ms) |
only affects to channel 2 – Strobe 1
025-064 |
0 |
5 | Dimmer 1 | 000-255 | 0 – 100% | 255 | |
6 | Dimmer 1 Fine | 000-255 | 0 – 100% | 255 | |
7 | Dimmer 2 | 000-255 | 0 – 100% | 255 | |
8 | Dimmer 2 Fine | 000-255 | 0 – 100% | 255 | |
9 | Dimmer 3 | 000-255 | 0 – 100% | 255 | |
10 | Dimmer 3 Fine | 000-255 | 0 – 100% | 255 | |
11 | Dimmer 4 | 000-255 | 0 – 100% | 255 | |
12 | Dimmer 4 Fine | 000-255 | 0 – 100% | 255 | |
13 |
Dimmer Curve |
000-51 | No Function – Current Preset from Menu Settings |
0 |
|
052-101 | Linear Dimmer Curve | ||||
102-152 | Exponential Dimmer Curve | ||||
153-203 | Logarithmic Dimmer Curve | ||||
204-255 | S-Curve Dimmer Curve |
14 |
Dimmer Response |
000-063 | No Function – Current Preset from Menu Settings |
0 |
|
064-127 | LED / fast | ||||
128-191 | Medium | ||||
192-255 | Halogen / slow | ||||
15 |
Redshift |
000-84 | No Function – Current Preset from Menu Settings |
0 |
|
085-170 | Redshift Off | ||||
171-255 | Redshift On | ||||
16 |
Effect |
000-40 | No Function |
0 |
|
041-083 | Effect 1 (slow to fast) | ||||
084-126 | Effect 2 (slow to fast) | ||||
127-169 | Effect 3 (slow to fast) | ||||
170-212 | Effect 4 (slow to fast) | ||||
213-255 | Effect 5 (slow to fast) | ||||
17 |
Device Settings (please see remark *1) |
000-029 | No function |
0 |
|
030-034 | Display Backlight On (hold 3s) | ||||
035-039 | Display Backlight Off (hold 3s) | ||||
040-044 | No function | ||||
045-049 | DMX Fail Blackout (hold 3s) | ||||
050-054 | DMX Fail Hold (hold 3s) | ||||
055-059 | DMX Fail – Emergency Light (hold 3s) | ||||
060-064 | No function | ||||
65-069 | RAW (hold 3s) | ||||
070-074 | User Calibrated (hold 3s) | ||||
075-079 | No function | ||||
080-084 | LED Frequency 800Hz (hold 3s) | ||||
085-089 | LED Frequency 1200Hz (hold 3s) | ||||
090-094 | LED Frequency 2000Hz (hold 3s) | ||||
095-099 | LED Frequency 3600Hz (hold 3s) | ||||
100-104 | LED Frequency 12kHz (hold 3s) | ||||
105-109 | LED Frequency 25kHz (hold 3s) | ||||
110-114 | No function | ||||
115-119 | Fan Auto (hold 3s) | ||||
120-124 | Fan Silent (hold 3s) | ||||
125-129 | Fan Off (hold 3s) | ||||
130-134 | Fan High Power (hold 3s) | ||||
135-139 | No function | ||||
140-144 | Invert Mapping Off (hold 3s) | ||||
145-149 | Invert Mapping CW (hold 3s) | ||||
150-154 | Invert Mapping CCW (hold 3s) | ||||
155-159 | No function | ||||
160-164 | LED Mode – Illumination (hold 1,5s) |
17 |
Device Settings (please see remark *1) |
165-169 | LED Mode – Boost (hold 1,5s) |
0 |
|
170-174 | No function | ||||
175-179 |
Factory Reset (hold 3s) |
Reset only starts if Shutter channel is set to DMX 250 | |||
180-184 |
User Reset (hold 3s) |
Reset only starts if Shutter channel is set to DMX 250 / no self-test by DMX | |||
185-255 | No function |
RDM Templates*
The ROXX Show series features support for various RDM functions.
RDM (Remote Device Management) is a protocol enhancement to USITT DMX512 that allows bi-directional communication between the fixtures and the controller over a standard DMX line. This protocol will allow configuration, status monitoring and management.
You will need a RDM controller to get control over the supported parameters. See the tables below for supported RDM features.
Label: | ROXX CLUSTER B4 W |
Model: | CLUSTER B4 W |
Manufacturer: | ROXX |
ID: | 6A6Ah |
Device ID: | 201 xxxx |
Note: During RDM identifying process CLUSTER B4 W flashes white alternately.
RDM functions
For easy identifying ROXX CLUSTER B4 W during RDM process the unit will strobe in white color.
PID | Function | Action | Values |
0x00F0 | DMX Start Adress | Set | 001-512 |
0x00E0 | DMX Personality | Set | 7x DMX modes |
0x00E1 | DMX Slots | Read | n.a. |
0x8001 | Effect | Set | 0= Stop Program / 1= Effect 1 / 2= Effect 2 / 3= Effect 3 / 4= Effect
4 / 5= Effect 5 |
0x8002 | Effect Dimmer | Set | |
0x8003 | Effect Speed | Set | |
0x8050 | Master / Slave | Set | 0= Master / 1= Slave |
0x0500 | Display Flip | Set | 0= Off / 1= On |
0x8051 | Display Backlight | Set | 0= Off / 1= On |
0x8052 | Display Lock | Set | 0= Off / 1= On |
0x8053 | Startup Mode | Set | 0= DMX / 1= AUTO / 2= Quick Light |
0x8054 | DMX Fail | Set | 1= Hold / 2= Blackout / 3= Emergency |
0x8055 | Dimmer Curve | Set | 1= Linear / 2= Exponential / 3= Logarithmic / 4= S-Curve |
0x8056 | Dimmer Response | Set | 1= LED / 2= Medium / 3= Halogen |
0x8057 | Redshift | Set | 0= Off / 1= On |
0x8058 | RAW Balance | Set | 0= RAW / 1= User Calibrated |
0x8024 | User Calibration-White 1 | Set | |
0x8023 | User Calibration- Amber 1 | Set | |
0x8020 | User Calibration- Red 1 | Set | |
0x8029 | User Calibration- White 2 | Set | |
0x8028 | User Calibration- Amber 2 | Set | |
0x8025 | User Calibration- Red 2 | Set | |
0x802E | User Calibration- White 3 | Set | |
0x802D | User Calibration- Amber 3 | Set | |
0x802A | User Calibration- Red 3 | Set |
0x8033 | User Calibration- White 4 | Set | |
0x8032 | User Calibration- Amber 4 | Set | |
0x802F | User Calibration- Red 4 | Set | |
0x8059 | LED Frequency (PWM) | Set | 1= 800Hz / 2= 1200Hz / 3= 2000Hz / 4= 3600Hz / 5= 12kHz / 6=
25kHz |
0x805A | Fan | Set | 0= Auto / 1= Silent / 2= Fan Off / 3= Max. Power |
0x805B | Invert Mapping | Set | 0= Off / 1= CW / 2= CCW |
0x805C | LED Mode | Set | 0= Illumination / 1= Boost |
0x805D | USB Update | Yes/No | 0= No / 1= Yes |
0x805E | Factory Reset | Yes/No | 0= No / 1= Yes |
0x805F | User Reset | Yes/No | 0= No / 1= Yes |
0x00C0 | Firmware Version | read | n.a. |
0x8700 | Serial Number | Read | n.a. |
0x0400 | Device Power on Time | Read | n.a. |
0x8701 | Temperature LED 1 | Read | n.a. |
0x8702 | Temperature LED 2 | Read | n.a. |
0x8703 | Temperature LED 3 | Read | n.a. |
0x8704 | Temperature LED 4 | Read | n.a. |
0x8705 | LED 1 on Time | Read | n.a. |
0x8706 | LED 2 on Time | Read | n.a. |
0x8707 | LED 3 on Time | Read | n.a. |
0x8708 | LED 4 on Time | Read | n.a. |
Sensors
RDM enables various readouts for remote device monitoring. See the table below for sensors and sensor types.
Please note: The RDM controller communicates with the fixtures to show only the available sensors for this fixture.
The table is subject to change without notice.
Name | |
Temperature | xx°C / xxx°F |
Software Version | SW-Version |
Errors |
TROUBLESHOOTING
Did you try turning the device off and on again?
Problem | Reason | Solution |
Device is not responding. |
No power. |
Check cable connections and conform that power is switched on. |
Fuse defect. | Contact your qualified service technician / manu- facturer. | |
Device has turned off. | Power failure or power was turned off. | Check power supply, fuse, connections, switches. |
Device has stopped responding. | DMX cable correct? | Check cables. |
Device operates strangely. |
DMX cable inverted (pins correct?) | Use a phase inverter or different cables. |
DMX cable terminated? | If not, install DMX termination at the end of the cable. | |
Stand Alone program running? | Stop internal Stand Alone. |
MANUFACTURER´S DECLARATION
Manufacturer´s Warranty & Limitations of Liability
Please find our warranty conditions and limitations of liability inside our manufacturer´s declaration at www.roxxlight.com/support
Requesting Warranty-Service
To request warranty service for your product, please contact:
ROXX GmbH,Hansestr. 91
51149 Köln
Email: info@roxxlight.com or the ROXX authorized reseller in your country, from where you purchased your product.
Correct Disposal of this product
This is for the European Union and European countries with electrical waste collection systems. When this label is shown on the product or brochure it means that the item cannot be disposed with household waste. In order to prevent damage to the environment or human health please do not dispose this product uncontrolled. Make sure to act responsible, recycle this product separately from other types of waste to enable lasting reuse of resources. Private users please contact the retailer where you purchased this product or your local authorities to find out where and how proper recycling of this item is possible. Business users please contact your supplier or check the terms and conditions of your purchasing contract. Make sure not to mix this product with other commercial waste.
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However,there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
CE Compliance
The equipment marketed by ROXX GmbH complies (where applicable) with the essential requirements and other specifications of the following Directives:
- 2014/30/EU (EMC)
- 2014/35/EU (LVD)
- 2011/65/EU (RoHS)
The complete EU- and UK-Declaration of Conformity can be found at www.roxxlight.com/support,or you can also request it at info@roxxlight.com
ROXX GmbH | Hansestr. 91 | 51149 Köln | www.roxxlight.com
Tel: +49 (0) 2203 20371-0 | Fax: +49 (0) 2203 20371-20
Documents / Resources
![]() |
ROXX B4-W CLUSTER Red LED [pdf] User Manual B4-W CLUSTER Red LED, B4-W, CLUSTER Red LED, Red LED, LED |