The Enttec DIN Pixie 73539 is a compact, DIN-rail mountable DMX to LED pixel protocol converter. It is designed to provide flexible control for architectural, commercial, and entertainment lighting installations by converting DMX512 signals into various LED pixel protocols.

This manual provides essential information for the safe and efficient operation of your DIN Pixie. Please read it thoroughly before installation and use.

2. Informații de siguranță

WARNING: This unit is intended for indoor use only. Do not expose to rain or moisture. Doing so will void the warranty.

  • Never plug this unit into a dimmer.
  • Always be sure to mount this unit in an area that will allow sufficient ventilation.
  • Label any RJ45/6 DMX connector and DO NOT connect to non-DMX port (e.g., Ethernet Switch). Connecting unlike systems could result in serious damage to Storm8 and equipment.
  • All ports feature ESD surge protection and resettable fuses to block external faults and electrical noise propagation.

3. Conținutul cutiei

Verificați dacă toate articolele sunt prezente în cutie:

  • Enttec DIN Pixie unit
  • Suport de montare DIN
  • USB Type-A to USB 2.0 Type B Cable

4. Suprasolicitare fizicăview și Conexiuni

Faţă view of Enttec DIN Pixie with status LED and branding

Figura 4.1: Față view of the Enttec DIN Pixie controller, showing the status LED and branding.

Top view of Enttec DIN Pixie showing DMX input ports

Figura 4.2: Sus view of the Enttec DIN Pixie, highlighting the two DMX input ports (DMX 1 and DMX 2) and the enttec.com URL.

Fund view of Enttec DIN Pixie showing USB and SPI outputs

Figura 4.3: De jos view of the Enttec DIN Pixie, showing the USB 2.0 Type-B input and two 3-pin Phoenix SPI output terminals (labeled 1 and 2) with VCC limit 5-48VDC.

4.1. DMX Input (RJ45)

The DIN Pixie features two RJ45 ports for DMX input. These ports are compliant with ANSI E1.27-2.

RJ45 Pin for DMX Input
PinFuncţie
Pinul 1Date +
Pinul 2Data -
Pin 7/8Sol

4.2. SPI Output (3 Pin Phoenix)

The unit provides two 3-pin Phoenix connectors for SPI output. These outputs deliver power and data to your LED pixels. Ensure the VCC limit of 5-48VDC is respected.

  • 0V: Ground connection for the pixel strip.
  • DATE: Data signal for the pixel strip.
  • VCC: Voltage supply for the pixel strip (5-48VDC).

4.3. USB 2.0 Type-B Input

A robust USB Type-B connector is provided for configuration and firmware updates. It is also backward compatible with the Enttec Pixie Driver API for USB-SPI control.

5. Configurare și instalare

5.1. Montare

The DIN Pixie is designed for DIN-rail mounting. Use the included DIN Mounting Bracket to secure the unit to a standard DIN rail.

Fund view of Enttec DIN Pixie with DIN rail clip attached

Figura 5.1: De jos view of the Enttec DIN Pixie showing the attached DIN rail mounting clip.

5.2. Alimentarea unității

The DIN Pixie operates on a wide voltage range of 5-48VDC. It can be powered from the same source as your LED pixels via the VCC and 0V terminals on the SPI output connectors. Alternatively, power can be supplied via the USB connection.

5.3. Connecting LED Pixels

Connect your LED pixel strips or dots to the SPI output terminals. Ensure correct polarity (0V, DATA, VCC) and that the voltage supplied matches the requirements of your pixel strips and is within the 5-48VDC limit of the DIN Pixie.

The DIN Pixie supports RGB and RGBW pixel strips and dots.

5.4. DMX Input Connection

Connect your DMX source to the RJ45 DMX input ports. The unit can receive DMX512-A data.

5.5. Configurare

The DIN Pixie is configurable and updatable via USB using Enttec's free PRO-MANAGER software. This software allows you to:

  • Configure DMX starting address.
  • Set pixel grouping functions to optimize channel usage.
  • Select between control modes.
  • Test output sequences (no external data source required).
  • Actualizați firmware-ul.

For the latest version of PRO-MANAGER software and drivers, visit the official Enttec website: enttec.com

6. Moduri de operare

The DIN Pixie supports various operating modes, indicated by the status LED:

  • PE: Overheating/Error
  • 0.5Hz: Inactiv
  • 2Hz: Standalone playback
  • 8Hz: Primirea DMX
  • 25Hz: Receiving from USB

6.1. Mod de control DMX

When receiving DMX data, the DIN Pixie converts up to 2 DMX universes (1024 channels) into SPI pixel protocols. The DMX starting address and pixel grouping can be configured via PRO-MANAGER.

The unit can be configured to play a show on DMX loss or blackout output, providing a fail-safe mechanism.

6.2. Standalone Playback Mode

The DIN Pixie has inbuilt flash memory for standalone show playback (4000 frames, approximately 100 seconds). Shows can be recorded and uploaded using PRO-MANAGER. Standalone playback can include sequence advance control options such as play count, loop delay, and play on power up.

6.3. USB Control Mode

The DIN Pixie can be controlled directly via the USB Type-B connector using the Enttec Pixie Driver API. This allows for direct control from a computer or compatible device.

7. Întreținere

The Enttec DIN Pixie is designed for reliable operation and requires minimal maintenance.

  • curatenie: Folosiți o lavetă moale și uscată pentru a curăța exteriorul unității. Nu utilizați agenți de curățare lichizi sau solvenți.
  • Actualizări firmware: Periodically check the Enttec website for firmware updates. Keeping the firmware current ensures optimal performance and access to new features. Firmware updates are performed using the PRO-MANAGER software.
  • Ventilare: Ensure the unit is mounted in an area with adequate ventilation to prevent overheating.

8. Depanare

If you encounter issues with your DIN Pixie, refer to the following common troubleshooting steps:

  • Fără indicatori de alimentare/LED opriți:
    • Check power connections to the VCC/0V terminals or USB port.
    • Asigurați-vă că sursa de alimentare voltage is within the 5-48VDC range.
    • Verificați dacă sursa de alimentare este activă.
  • No Pixel Output:
    • Confirm correct wiring of 0V, DATA, and VCC to the pixel strips.
    • Check if the DMX source is active and sending data (status LED should be 8Hz).
    • Verify pixel protocol and DMX starting address settings in PRO-MANAGER.
    • Ensure the pixel strips themselves are functional.
  • DMX Input Not Detected (LED 8Hz not flashing):
    • Check DMX cable connections.
    • Ensure the DMX source is transmitting.
    • Confirm the DMX source is using USITT DMX512-A protocol.
  • PRO-MANAGER Connection Issues:
    • Asigurați-vă că cablul USB este bine conectat.
    • Install the correct FTDI drivers for your operating system. Refer to the Enttec website cu informații pentru șoferi.
    • Restart PRO-MANAGER and reconnect the USB cable.
  • Overheating/Error (LED ON):
    • Check for adequate ventilation around the unit.
    • Ensure the ambient temperature is within the operating range (0°C to 50°C).
    • Reduce the load on the SPI outputs if possible.

For further assistance, please contact Enttec support or visit their website for detailed guides and FAQs.

9. Specificații

CaracteristicăCaietul de sarcini
Conectori1x USB 2.0 Type-B Input, 2x DMX Input (RJ45), 2x SPI Output (3 Pin Phoenix)
Protecție ESDResettable fuse per port
Evaluare IPIP20
Indicator LEDYes (Power and output status)
Protocol de intrareUSITT DMX512-A
Data Output TypeSPI (Supported protocols listed on Enttec website)
Maximum Output Channels2 Universes (1024ch), duplicated on both ports
Max. Output Refresh Rate40 FPS
Latența5 milisecunde
Vol. De intraretage5 - 48V DC (via USB/Ether output port VCC terminal)
Putere maximă1.5W
Max. Rated Current per screw terminal (VCC / 0V)10A
Software de configurarePRO-MANAGER
Actualizări de firmwarePRO-MANAGER
Show Recording/UploadPRO-MANAGER
Temperatura de funcționare a mediului0°C până la 50°C (32°F până la 122°F)
Umiditatea mediului de funcționare5-95% (fără condensare)
Materialul corpuluiPlastic ABS
Opțiune de montareDIN
Greutate unitară95 g / 3.3 oz
Dimensiuni (H x W x L)1.22 x 3.07 x 3.66 inchi (30.9 x 77.9 x 92.98 mm)
Greutate de livrare0.22kg / 0.49lbs

Note: For the most current and detailed specifications, please refer to the official Enttec datasheet on their website-ul.

10. Garanție și asistență

10.1. Garantie

The Enttec DIN Pixie comes with a 2-year return to base manufacturer warranty, supported by 3rd party software. For detailed warranty terms and conditions, please visit the official Enttec website-ul.

10.2. Suport tehnic

For technical assistance, troubleshooting, or further information, please visit the Enttec website-ul sau contactați echipa lor de asistență:

  • Website: www.enttec.com
  • Consultați website pentru date de contact și resurse de asistență.

Documente conexe - 73539

Preview Manual de utilizare ENTTEC DIN PIXIE: Controler SPI Pixel Strip/Dot
Manual de utilizare pentru ENTTEC DIN PIXIE, un controler SPI Pixel Strip/Dot care gestionează 2 universuri de pixeli LED pe două ieșiri. Acoperă siguranța, specificațiile, cablarea, caracteristicile funcționale (USB, DMX, moduri Standalone), software-ul PRO-Manager, configurarea dispozitivului, actualizările de firmware, testarea, montarea, întreținerea, conținutul pachetului și informații despre comandă.
Preview Ghid de creare a protocolului personalizat ENTTEC: Controlul dispozitivelor de fixare a pixelilor
Învață cum să creezi protocoale personalizate de pixeli LED pentru controlere ENTTEC precum DIN PIXIE și PIXELATOR MINI folosind acest ghid complet. Ajustează volumultagsincronizarea și verificarea fișelor tehnice.
Preview Manual de utilizare și specificații tehnice ENTTEC Phero 33
Manual de utilizare complet pentru ENTTEC Phero 33, care detaliază caracteristicile, configurarea, instalarea, adresarea DMX, specificațiile tehnice și informațiile de comandă. Include un tabel detaliat cu patch-uri DMX.
Preview Manual de utilizare ENTTEC OCTO MK3: Controler eDMX către SPI Pixel
Manual de utilizare complet pentru ENTTEC OCTO MK3, un controler versatil de la eDMX la pixel SPI cu mod autonom și funcții de overdrive. Aflați despre instalare, configurare, conectare în rețea și depanare.
Preview ENTTEC PIXELATOR MINI MK2: Manual de utilizare pentru controlul pixelilor de la eDMX la SPI
Manual de utilizare complet pentru ENTTEC PIXELATOR MINI MK2, un controler de pixeli eDMX către SPI cu 16 porturi. Aflați despre instalare, configurare, conectare în rețea și funcții avansate pentru un control fiabil al iluminării pixelilor la distanță lungă.
Preview Manual de utilizare ENTTEC PIXELATOR MINI (70067): Controler de pixeli eDMX către SPI
Manual de utilizare complet pentru ENTTEC PIXELATOR MINI (70067), care detaliază caracteristicile, instalarea, configurarea, conectarea la rețea și depanarea pentru controlul pixelilor de la eDMX la SPI.