1. Introducere

This instruction manual provides essential information for the safe and efficient installation, operation, and maintenance of the Danfoss BFP 21 L3 Oil Burner Pump, model 071N0107. Please read this manual thoroughly before attempting any procedures to ensure proper function and to prevent damage or injury.

2. Informații de siguranță

AVERTIZARE: To prevent health and bodily harm, installation, maintenance, initial commissioning, repairs, and other inspections must be carried out by authorized professionals, such as contractual installation companies or qualified technicians. Improper installation or service can lead to serious injury or equipment damage.

3. Produs terminatview

The Danfoss BFP 21 L3 is a high-quality oil burner pump designed for reliable fuel delivery in heating systems. This model, 071N0107, is a direct replacement for the BFP 31 series and features a left rotation and an 8 mm shaft diameter.

Danfoss BFP 21 L3 Oil Burner Pump, front view

Figura 3.1: Față view of the Danfoss BFP 21 L3 Oil Burner Pump. This image shows the main body of the pump with its shaft extending forward, ready for connection to a motor.

Danfoss BFP 21 L3 Oil Burner Pump, side view cu etichetă

Figura 3.2: lateral view of the Danfoss BFP 21 L3 Oil Burner Pump, highlighting the product label. The label clearly displays "BFP 21 L3" and "071N0107", along with other technical markings and certifications.

Danfoss BFP 21 L3 Oil Burner Pump, rear view de arbore

Figura 3.3: Spate view of the Danfoss BFP 21 L3 Oil Burner Pump, focusing on the shaft connection point. This perspective shows the robust construction around the shaft, indicating its connection to the burner motor.

Caracteristici cheie:

4. Configurare și instalare

Installation of the Danfoss BFP 21 L3 oil burner pump should only be performed by a qualified technician. Incorrect installation can lead to system malfunction, fuel leaks, or fire hazards. The following steps are general guidelines; always refer to the specific burner manufacturer's instructions and local codes.

  1. Preparare: Ensure the burner system is completely shut down and power is disconnected. Close all fuel supply valves.
  2. Demontarea pompei vechi: Carefully disconnect fuel lines and electrical connections from the old pump. Note the orientation and connections for proper reinstallation. Remove mounting bolts and detach the old pump.
  3. Mounting the New Pump: Position the new Danfoss BFP 21 L3 pump, ensuring the shaft aligns correctly with the motor coupling. Secure the pump using the appropriate mounting bolts.
  4. Connecting Fuel Lines: Connect the suction and return fuel lines to the designated ports on the pump. Ensure all connections are tight and sealed to prevent leaks.
  5. Conexiuni electrice: Reconnect electrical wiring according to the burner manufacturer's diagram. Verify correct polarity and secure all connections.
  6. Amorsarea pompei: After installation, the pump may need to be primed to remove air from the fuel lines. Follow the burner manufacturer's procedure for priming.
  7. Verificarea scurgerilor: Before full operation, perform a thorough leak check on all fuel connections.
  8. Pornire inițială: Restore power and fuel supply. Carefully observe the burner's operation during initial start-up, checking for proper ignition and fuel delivery.

5. Instrucțiuni de utilizare

The Danfoss BFP 21 L3 oil burner pump operates as an integral part of your heating system. Once properly installed and commissioned by a professional, its operation is typically automatic, controlled by the burner's control unit.

6. Întreținere

Regular maintenance is crucial for the longevity and efficient operation of your Danfoss BFP 21 L3 oil burner pump and the entire heating system. All maintenance procedures should be carried out by a qualified service technician.

7. Depanare

This section provides general troubleshooting tips. For complex issues or if you are unsure, always contact a qualified service technician.

ProblemăCauza posibilaSoluţie
Arzătorul nu se aprindeNo fuel delivery, air in lines, clogged nozzle, faulty ignition.Check fuel supply, prime pump, inspect/clean nozzle, check ignition system. Contactati tehnicianul.
Pompa face zgomot neobișnuitAir in fuel, worn bearings, foreign object.Check for air leaks in suction line, inspect pump. Contactati tehnicianul.
Oil leakage from pumpConexiuni slăbite, garnituri deteriorate.Tighten connections, replace seals. Contactati tehnicianul.
Inconsistent flame or poor combustionIncorrect pressure, partially clogged nozzle, air in fuel.Check/adjust pressure, clean/replace nozzle, bleed air. Contactati tehnicianul.

8. Specificații

Below are the key specifications for the Danfoss BFP 21 L3 Oil Burner Pump (Model 071N0107).

9. Garanție și asistență

For warranty information and technical support, please refer to the documentation provided with your purchase or contact your authorized Danfoss dealer or service center. Keep your proof of purchase for warranty claims.

Danfoss does not provide specific information regarding spare parts availability directly to end-users. Please consult with your authorized service provider for spare parts inquiries.