Atlantic FP300

Atlantic Water Gardens FP300 Adjustable Flow Fountain and Water Feature Pump

Manual de instructiuni

1. Introducere

The Atlantic Water Gardens FP300 Adjustable Flow Fountain and Water Feature Pump is designed for small submersible applications, offering reliable and adjustable performance for various water features. This pump features a compact design, integrated flow control, and a durable pre-filter to ensure longevity and efficiency.

Caracteristici cheie:

  • Magnetic Induction performance with replaceable components.
  • Compact size suitable for small wall and tabletop fountains.
  • Integrated valve for convenient flow adjustment.
  • Removable and washable foam filter protects internal components.
  • Standard size fittings for versatile tubing connections.
  • Energy-efficient motor for reduced operating costs.
  • Tool-free impeller assembly replacement for extended service life.

2. Informații de siguranță

Please read and understand all instructions before operating this pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always disconnect the pump from the power supply before handling or performing any maintenance.
  • Asigurați-vă că pompa este complet scufundată în apă în timpul funcționării pentru a preveni supraîncălzirea.
  • Do not operate the pump with a damaged cord or plug. If the cord is damaged, it must be replaced by the manufacturer or a qualified service agent.
  • This pump is designed for use with water only. Do not use with flammable liquids.
  • Keep children and pets away from the water feature during operation.
  • Ensure the electrical outlet is properly grounded and protected by a Ground Fault Circuit Interrupter (GFCI).

3. Conținutul pachetului

Verificați dacă toate componentele sunt prezente și nedeteriorate:

  • Atlantic Water Gardens FP300 Pump
  • Assorted Nozzle Adapters (typically 3 sizes)
  • Manual de instructiuni

4. Configurare

Follow these steps to set up your FP300 pump:

  1. Inspectați pompa: Before installation, visually inspect the pump for any signs of damage.
  2. Choose an Adapter: Select the appropriate nozzle adapter for your tubing size. The pump typically comes with three different sizes to accommodate various plumbing setups. Screw the chosen adapter onto the pump's outlet.
  3. Tubul de conectare: Attach your water feature's tubing to the installed adapter. Ensure a secure connection to prevent leaks.
  4. Plasare: Place the pump in the desired location within your water feature. The pump is designed for submersible use and should be fully immersed in water. The strong suction cups on the base of the pump allow for secure mounting to the bottom or side of your water feature.
  5. Reglați controlul debitului: The pump features an integrated flow control valve. Adjust this valve to achieve your desired water flow rate.
  6. Conexiune de alimentare: Once the pump is securely placed and connected to the tubing, plug the power cord into a properly grounded GFCI outlet.
Atlantic Water Gardens FP300 pump with dimensions

Figure 1: Atlantic Water Gardens FP300 pump with dimensions (5"L x 3"W x 3.25"H).

Atlantic Water Gardens FP300 pump showing dimensions

Figura 2: Detaliat view of the FP300 pump, highlighting its compact design and dimensions.

Video 1: This video demonstrates the general features of a water fountain pump, including its powerful rotor, strong suction cups for secure placement, and an auto low water power OFF system for safety and longevity. It also shows the pump's application in various water features.

Video 2: This video illustrates the installation process of a water pump, showing how to attach the different nozzle adapters and place the pump in a fountain. It highlights the adjustable flow feature and demonstrates the pump's operation in a small fountain.

5. Funcționarea pompei

Once installed, the FP300 pump is designed for continuous operation. Ensure the water level in your fountain or water feature is always sufficient to keep the pump fully submerged. The pump features an auto shut-off system that activates if the water level becomes too low due to evaporation, protecting the pump from dry running damage.

To adjust the flow rate, locate the flow control valve on the pump and turn it to increase or decrease the water output. This allows you to customize the water flow to suit your specific water feature and desired effect.

For optimal performance and to select the correct pump for your specific water feature application, it is crucial to calculate the Total Dynamic Head (TDH). The TDH is the measure of work your pump will have to perform, considering factors like the width of your waterfall, tubing length, and vertical head height. Refer to the following video for a detailed guide on calculating TDH.

Video 3: This official Atlantic Water Gardens video provides a comprehensive guide on 'Choosing the Perfect Pump' by calculating the Total Dynamic Head (TDH). It explains how to determine the required flow (GPH), select appropriate tubing and multiplier, add equivalent tubing lengths, calculate friction head, and finally, find the TDH to choose the most efficient pump for your water feature.

6. Întreținere

Regular maintenance will ensure the longevity and efficient operation of your FP300 pump:

  • Curățarea filtrului: The pump is equipped with a removable and washable foam filter. Periodically remove the filter and rinse it thoroughly under clean water to remove any debris, algae, or sediment. A clogged filter can reduce pump performance and lead to premature wear.
  • Inspecția rotorului: Over time, the impeller may accumulate debris or show signs of wear. The impeller assembly can be replaced quickly without tools. Refer to the pump diagram for instructions on accessing and replacing the impeller.
  • winterization: In freezing climates, remove the pump from the water feature before the first freeze. Clean the pump thoroughly and store it in a frost-free location, submerged in a bucket of water to keep seals moist, or completely dry if recommended by the manufacturer.

7. Depanare

ProblemăCauza posibilaSoluţie
Pompa nu funcționeazăNo power; clogged impeller; damaged impeller; low water level.Check power connection and GFCI; clean impeller; replace impeller; ensure pump is fully submerged.
Debit scăzut de apăClogged filter; kinked tubing; flow control valve closed; insufficient water level.Clean filter; straighten tubing; open flow control valve; add water to feature.
Pompa este zgomotoasăDebris in impeller; pump not fully submerged; pump vibrating against surface.Clean impeller; ensure full submersion; reposition pump or use dampmaterial ening.

8. Specificații

AtributValoare
Marcaatlantic
ModelFP300
Debitul300 GPH (galoane pe oră)
CuloareNegru
MaterialPlastic
Dimensiunile produsului5 cm L x 3 cm l x 3.25 cm Î
Sursa de alimentareElectric cu fir
Voltage115V
Greutatea articolului1 Lira
UPC727429003527

9. Garanție și asistență

For warranty information, technical support, or replacement parts, please contact Atlantic Water Gardens customer service. Keep your purchase receipt as proof of purchase for any warranty claims.

Informații de contact: Refer to the official Atlantic Water Gardens website-ul sau ambalajul produsului pentru cele mai recente date de contact.

Documente conexe - FP300

Preview Manual de utilizare și ghid de instalare pentru deversorul Atlantic Spillway Scupper
Comprehensive operating manual for Atlantic Stainless Steel and Copper Finished Spillway Scuppers (models SS12, SS24, SS36, CS12, CS24, CS36). Includes detailed installation requirements, plumbing instructions, maintenance tips, winterization guide, and warranty information for these pond-free and fountain water features.
Preview Manual de produs TWVSC-73933, controler de viteză variabilă Atlantic TidalWave (VSC)
Acest manual de produs pentru regulatorul de viteză variabilă (VSC) Atlantic TidalWave TWVSC-73933 detaliază caracteristicile, instalarea, funcționarea prin intermediul aplicației Atlantic Control, măsurile de siguranță, întreținerea și depanarea. Acesta permite controlul prin Bluetooth® pentru pompele din seria Atlantic TT.
Preview Manuel d'installation et d'utilisation Atlantic Doris Mixte : Radiateur Sèche-Serviettes
Découvrez le radiateur sèche-serviettes mixte Atlantic Doris. Ce manuel fournit des instructions détaillées pour l'installation, l'utilisation, la programmation et l'entretien de votre appareil, assurant confort et efficacité dans votre salle de bain.
Preview Atlantic DOMOCABLE Heating Cable: Installation and User Manual
Comprehensive guide for installing and operating the Atlantic DOMOCABLE heating cable system, including thermostat setup, programming, remote control, and safety precautions.
Preview Manual de instalare și utilizare: Chauffe-eau Électrique Atlantic
Acest manual oferă instrucțiuni detaliate pentru instalare, utilizare sigură și întreținere a șoferului cu apă electrică a mărcii Atlantic. Se acoperă aspectele esențiale cum ar fi expedițiile de securitate, racordurile hidraulice și electrice, punerea în serviciu și informațiile de garanție.
Preview Atlantic Sokio Gentle Heat Radiator Quick Start Guide
A quick start guide for the Atlantic Sokio Gentle Heat Radiator, covering setup, navigation, operating modes, and programming features for optimal room temperature control.