RICE LAKE WEIGHING SYSTEMS 882IS Plus Intrinsically Safe Digital Weight Indicator Instructions

882IS Plus Intrinsically Safe Digital Weight Indicator

Specifications:

The 882IS/882IS Plus indicator is certified for use in hazardous
locations per United States, Canadian, ATEX, and IECEx
standards.

  • Certificate No: FM18US0195X, FM18CA0092X, FM22UKEX0061X,
    FM18ATEX0047X, IECEx FMG 18.0018X
  • Equipment Ratings: FM/cFM: INTRINSICALLY SAFE Class I, II, III,
    Division 1, Groups ABCDEFG T4

Product Usage Instructions:

Conditions of Use in Hazardous Locations:

The 882IS/882IS Plus is certified as intrinsically safe and
suitable for hazardous locations when following the conditions
outlined in the document. Ensure compliance with Factory Mutual
(FM) Approvals for any revisions.

Certification and Classification:

The indicator is certified for hazardous locations in the United
States, Canada, UK, ATEX, and IECEx according to specified
standards.

Specific Conditions of Use:

Make sure to adhere to the approval standards outlined for the
United States and Canada regarding electrical equipment usage in
hazardous locations.

Model IS6V2 (Battery) Usage:

For the IS6V2 model battery, follow the guidelines provided in
the certification documents FM18US0195X, FM18CA0092X,
FM22UKEX0061X, FM18ATEX0047X, and IECEx FMG 18.0018X.

Model mb-EPS-100-240-X2 (Power Supply) Usage:

When using the power supply model mb-EPS-100-240-X2, ensure
compliance with the equipment ratings and certification numbers
specified for hazardous locations.

FAQ:

What should I do if I encounter issues with the product in a
hazardous location?

If you face any problems with the product while in use in a
hazardous location, immediately stop usage and consult the user
manual for troubleshooting steps. If the issue persists, contact
customer support for further assistance.

Can I modify or repair the product on my own?

Modifying or attempting to repair the product on your own is
highly discouraged as it may void the certification for hazardous
location use. Seek professional assistance or contact authorized
service centers for any repairs or modifications required.

882IS/882IS Plus
Conditions of Use in Hazardous Locations

The 882IS/882IS Plus is certified as being intrinsically safe and appropriate for use in hazardous locations as long as the conditions of use stated in this document are followed. This is a controlled document, any revisions must be reviewed by Factory Mutual (FM) Approvals.

Certification and Classification
The 882IS/882IS Plus indicator is certified for use in hazardous locations per United States, Canadian, ATEX and IECEx standards.

882IS/882IS Plus Hazardous (Classified) Location Electrical Equipment Per U.S., Canadian, UK, ATEX and IECEx Requirements

Certificate No:

FM18US0195X, FM18CA0092X, FM22UKEX0061X, FM18ATEX0047X, IECEx FMG 18.0018X

Equipment Ratings: FM/cFM:

INTRINSICALLY SAFE Class I,II,III, Division 1, Groups ABCDEFG T4
Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135°C Db Ta = -10°C to +40°C (14°F to 104°F)

ATEX/IECEx

II 1 G Ex ia IIC T4 Ga II 2 D Ex ib IIIC T135°C Db

Model IS6V2 (Battery) Hazardous Location Electrical Equipment Per U.S., Canadian, UK, ATEX and IECEx Requirements

Certificate No:

FM18US0195X, FM18CA0092X, FM22UKEX0061X, FM18ATEX0047X, IECEx FMG 18.0018X

Equipment Ratings: FM/cFM:

INTRINSICALLY SAFE IS for Class I,II,III, Division 1, Groups ABCDEFG T4 Class I, Zone 0 AEx/Ex ia IIC T4 Ga Zone 21 AEx/Ex ib IIIC T135°C Db Ta = -10°C to +40°C (14°F to 104°F)

ATEX/IECEx

II 1 G Ex ia IIC T4 Ga II 2 D Ex ib IIIC T135°C Db

October 12, 2023

PN 191698 Rev D

882IS/882IS Plus

Model mb-EPS-100-240-X2 (Power Supply) Hazardous Location Electrical Equipment Per U.S., Canadian, UK, ATEX and IECEx Requirements

Certificate No: Equipment Ratings:

FM18US0195X, FM18CA0092X, FM22UKEX0061X, FM18ATEX0047X, IECEx FMG 18.0018X FM/cFM:

Class I,II,III, Division 1, Groups ABCDEFG T4 with IS outputs for Class I,II,III, Division 1, ABCDEFG Class I, Zone 1, AEx/Ex mb [ia Ga] IIC T4 Gb Zone 21, AEx/Ex mb [ia Da] IIIC T135°C Db Ta = -10°C to +40°C (14°F to 104°F)
ATEX/IECEx

II 2(1) G Ex mb [ia Ga] IIC T4 Gb II 2(1) D Ex mb [ia Da] IIIC T135°C Db

Specific Conditions of Use
WARNING: · The surface of the LCD display of the 882IS/882IS Plus weight indicator is considered to constitute an electrostatic
discharge hazard. Clean only with a damp cloth. · The IS6V2 battery module cable lockout device must be installed over the connection between the battery and the cable.
The lockout device must be in place at all times in the hazardous area and can only be removed in a non-hazardous area. The lockout device must be re-installed prior to re-entering the hazardous area. · The IS6V2 battery module is for use only with the Model NP10-6 battery manufactured by ENERSYS.
AVERTISSEMENT: · La surface de l’écran LCD de I’indicateur de poids 882IS/882IS Plus est considéréé comme présentant un risque de décharge
électrostatique. Nettoyez uniquement avec un chiffon humide. · L’appareil de verrouillage du câble du module de batterie IS6V2 doit être installé sur la connexion entre la batterie et le
câble. L’appareil de verrouillage doit toujours être en place dans la zone hasardeuse et ne peut être retiré que dans une zone non hasardeuse. L’appareil de verrouillage doit être réinstallé avant de rentrer dans la zone hasadeuse. · Le module de batterie IS6V2 doit être utilisé uniquement avec la batterie modèle NP 10-6 fabriquée par ENERSYS.

Approval Standards

United States

Title

Number

Electrical Equipment for Use in Hazardous (Classified) Locations – General Requirements

FM Class 3600

Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II & III, Division I, Hazardous (Classi- FM Class 3610 fied) Locations

Explosion-Proof Electrical Equipment General Requirements

FM Class 3615

Electrical Equipment for Measurement, Control and Laboratory Use

FM Class 3810

Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use – Part 1: General ANSI/ISA 61010-1

Requirements

(82.02.01)

CSA C22.2 No. 1010.1

ANSI/UL 61010-1

Explosive Atmospheres – Part 0: Equipment – General Requirements

ANSI/ISA 60079-0

Explosive Atmospheres – Part 11: Equipment protection by intrinsic safety “i”

ANSI/ISA 60079-11

Explosive Atmospheres – Part 18: Equipment protection by encapsulation “m”

ANSI/ISA 60079-18

Degrees of Protection Provided by Enclosures (IP Code)

ANSI/IEC 60529

Table 1. United States Approval Standards

Issue Date 2018 2018
2018 2018 2015
2013 2011 2015 2004

2

Visit our website www.RiceLake.com

882IS/882IS Plus

Canadian

Title

Number

General Requirements – Canadian Electrical Code, Part II Bonding of Electrical Equipment Threaded Conduit Entries Enclosures for Use in Class II Groups E, F and G Hazardous Locations Explosion-Proof Enclosures for Use in Class I Hazardous Locations Explosive Atmospheres – Part 0: Equipment – General Requirements
Explosive Atmospheres – Part 11: Equipment Protection by Intrinsic Safety “i”
Explosive Atmospheres – Part 18: Equipment Protection by Encapsulation “m”
Degrees of Protection Provided by Enclosures (IP Code)
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory use – Part 1: General Requirements

CSA C22.2 No. 0
CSA C22.2 No. 0.4
CSA-C22.2 No. 0.5
CSA C22.2 No. 25
CSA C22.2 No. 30
CAN/CSA-C22.2 No. 60079-0
CAN/CSA-C22.2 No. 60079-11
CAN/CSA-C22.2 No. 60079-18
CAN/CSA C22.2 No. 60529
CAN/CSA C22.2 No. 61010-1

Table 2. Canadian Approval Standards

Issue Date R2015 2017 R2012 2017 R2012 2015
2014
2016
2005
2015

IEC
Title Electrical Apparatus for Explosive Gas Atmospheres. Part 0: General Requirements Explosive Atmospheres Part 11: Equipment Protection by Intrinsic Safety “i” Explosive Atmospheres — Part 18: Equipment Protection by Encapsulation “m”
Table 3. IEC Approval Standards

Number
IEC 60079-0 IEC 60079-11 IEC 60079-18

Issue Date
2018 2011 2014

ATEX
Title Electrical Apparatus for Explosive Gas Atmospheres. Part 0: General Requirements Explosive Atmospheres Part 11: Equipment Protection by Intrinsic Safety “i” Explosive Atmospheres — Part 18: Equipment Protection by Encapsulation “m” Degrees of Protection Provided by Enclosures (IP Code)
Table 4. ATEX Approval Standards

Number
EN 60079-0 EN 60079-11 EN 60079-18 EN 60529 +A1 +A2

Issue Date
2018 2012 2015 1991 2000 2013

© Rice Lake Weighing Systems All Rights Reserved

3

882IS/882IS Plus
Conditions of Use
Service
The entire unit must be shipped back to Rice Lake Weighing Systems for repair. Please contact a local dealer or Rice Lake Weighing Systems to obtain a return material authorization (RMA). There are no user serviceable parts within the 882IS/882IS Plus. All repairs are to be performed by the manufacturer. Removing the serial tag compromises the FM rating.
Equipment
An optional battery, Rice Lake Weighing Systems PN 180831, can be used to power the 882IS/882IS Plus. This battery must be charged using the Rice Lake Weighing System’s battery charger, PN 191394. The charger is 90-230 VAC auto detecting. Use of any other battery or battery charger voids the intrinsically safe certification and can damage the battery and other components.
WARNING: Failure to heed could result in serious injury or death. · The battery must be charged in a non-hazardous area. Do not bring the battery charger into a hazardous area. · The battery charger is not certified for use in hazardous environments. · The IS6V2 battery module can be removed from the product in the hazardous environment, but must be charged in a
non-hazardous area. · The IS6V2 battery module cable lockout device must be installed over the connection between the battery and the cable.
The lockout device must be in place at all times in the hazardous area and can only be removed in a non-hazardous area. The lockout device must be re-installed prior to re-entering the hazardous area.
AVERTISSEMENT: Le non-respect des directives pourrait entraîner des blessures graves ou la mort. · La batterie doit être chargée dans une zone non dangereue. N’amène pas le chargeur de batterie dans une zone
dangereuse. · La chargeur de batterie n’est pas certifié pour une utilisation dans des environnements dangereux. · La IS6V2 batterie peut être retirée du produit dans un environnement dangereux, mais doit être chargée dans une zone
non dangereuse. · L’appareil de verrouillage du câble du module de batterie IS6V2 doit être installé sur la connexion entre la batterie et le
câble. L’appareil de verrouillage doit toujours être en place dans la zone hasardeuse et ne peut être retiré que dans une zone non hasardeuse. L’appareil de verrouillage doit être réinstallé avant de rentrer dans la zone hasadeuse.
IMPORTANT: The 882IS/882IS Plus must not be used in locations where ambient temperature falls outside -10°C to +40°C (14°F to 104°F).

Connecting AC Power to the mb-EPS-100-240-X2 Power Supply
The power supply AC line voltage must be run through rigid metal conduit and properly sealed. The installer must comply with Rice Lake Weighing Systems control drawings as well as national and local electrical codes for installation of equipment in hazardous areas. An appropriate conduit seal rated for the hazardous area is required at enclosures entrance for AC power.

882IS Cable Glands

Cable Gland Size Cable Diameter Range Dome Nut Torque Around Cable

PG9 PG11

4-8mm (0.157-0.15″) 5-10mm (0.197-0.394″)

2.5 N-m (22 in-lb) 2.5 N-m (22 in-lb)

Table 5. Cable Gland Specification

4

Visit our website www.RiceLake.com

882IS/882IS Plus Indicator System Limitations and Restrictions
The following label will be affixed to the 882IS/882IS Plus Indicator.

882IS/882IS Plus

Figure 1. 882IS and 882IS Plus Indicator Label · All instrumentation must have identification nameplates in compliance with control drawings · Field modifications are not permitted · It is mandatory to return the 882IS/882IS Plus to Rice Lake Weighing Systems for service
NOTE: Install per Rice Lake Weighing Systems control drawing PN 221416.
Model IS6V2 Battery Box System Limitations and Restrictions
The following label will be affixed to the IS6V2 battery box.

Figure 2. IS6V2 Battery Box Label · All instrumentation must have identification nameplates in compliance with control drawings · Field modifications are not permitted · It is mandatory to return the IS6V2 battery box to Rice Lake Weighing Systems for service
NOTE: Install per Rice Lake Weighing Systems control drawing PN 186430.
Model mb-EPS-100-240-X2 Power Supply
The following label will be affixed to the mb-EPS-100-240-X2 power supply.

Figure 3. mb-EPs-100-240-X2 Power Supply Label
· All instrumentation must have identification nameplates in compliance with control drawings · Field modifications are not permitted · It is mandatory to return the mb-EPS-100-240-X2 power supply to Rice Lake Weighing Systems for service
NOTE: Install per Rice Lake Weighing Systems control drawing PN 182301.

© Rice Lake Weighing Systems All Rights Reserved

5

© Rice Lake Weighing Systems Content subject to change without notice. 230 W. Coleman St. · Rice Lake, WI 54868 · USA USA: 800-472-6703 · International: +1-715-234-9171

October 12, 2023

www.ricelake.com

PN 191698 Rev D