Record Control Unit BDE-D
User manual
Your global partner
for entrance solutions
www.record.group
List of changes
Change | Location |
Complete revision of all sections and content | Entire document |
New section structure | Entire document |
Revision of all graphics | Entire document |
Safety
1.1 Presentation of warning signs
DANGER
Warning against an imminent or latent hazardous situation that can lead to electric shock and cause serious injury or death.
DANGER
Warning against an imminent hazardous situation that can lead to severe injury or death.
WARNING
Warning against a latent hazardous situation that can lead to severe injuries or death and cause substantial property damage.
CAUTION
Warning against a potential hazardous situation that can lead to minor personal injury and property damage.
NOTICE
Useful advice and information to make sure of a correct and efficient workflow of the system.
1.2 Electronic equipment reception interference
The equipment can generate and use radio frequency energy. If the equipment is not installed and used properly it can cause interference to radio, television reception or other radio frequency type systems.
If other equipment does not fully comply with immunity requirements, interference may occur. There is no guarantee that interference will not occur in a particular installation.
If the equipment causes interference to radio or television reception, try to correct the interference:
a) Turn the equipment ON and OFF to determine interference.
b) Reorient the receiving antenna.
c) Move the receiver with respect to the equipment.
d) Move the receiver away from the equipment.
e) Connect the receiver into a different outlet so that equipment and receiver are on different branch circuits.
f) Make sure that protective earth () is connected.
If necessary, consult the dealer or an experienced electronics technician for additional suggestions.
1.3 State of technology
NOTICE
Installation, commissioning, inspection, and maintenance must only be done by approved technicians. We recommend you to have a service agreement.
Record the work in the check list and give it to the customer for safe keeping.
This system was developed using state of the art technology and officially recognized technical safety regulations. The system, depending on its options and variants, comply with the requirements of the Machine Guidelines 2006/42/EG as well as EN 16005 and DIN 18650 (D).
Danger can occur if you do not use the system as intended.
1.4 Product liability
To guarantee a reliable and trouble-free operation of the system, only use parts that the manufacturer recommends. The manufacturer declines any liability for damages as a result of unapproved modifications to the system or the use of parts that are not permitted.
Refer to regulations, the responsibility of the owner or caretaker of the equipment are as follows:
- That the equipment operates correctly, so that it gives sufficient protection in regard to safety and health.
- That someone with documented competence in the equipment and in applicable regulations oper- ates and regularly maintains, inspects, and services the equipment.
- That the provided Service log book and Site acceptance test and risk assessment are kept avail- able for maintenance and service records.
- That the inspection covers the emergency opening function (when applicable).
- That the closing force is appropriate for the system size on fire-approved systems (when applic-able).
1.5 Spare parts and liability
Reliable and trouble-free operation of the door is only guaranteed when using parts that were recommended by the manufacturer. The manufacturer declines any liability for damages resulting from unauthorized modifications to the door or the use of parts that are not permitted.
General information
2.1 Purpose and use of the instructions
These instructions are an integral part of the system and enable efficient and safe handling of the system.
In order to ensure proper functioning, the instructions must be accessible at all times and kept in the immediate area of the system. Although only the male form has been chosen for reasons of better legibility, the information refers to members of both sexes.
The operator must have read and understood the manual before starting any work. The basic requirement for safe working is to follow the safety instructions and the handling instructions. In addition, the local regulations and safety rules apply.
The manual can be handed over in extracts to instructed personnel who are familiar with the operation of the system.
The illustrations are for basic understanding and may differ from the actual presentation. Specific representations are contained in the drawings.
NOTICE
A replacement of the instructions is available from the supplier or on the website.
2.2 Manufacturer agtatec ag
agtatec ag
Allmendstrasse 24
CH – 8320 Fehraltorf
Switzerland
Phone: +41 44 954 91 91
2.3 Target groups
WARNING
Risk of injury if the personnel are not approved.
If unapproved personnel work on the system or are in the danger zone of the system, dangers can occur. Severe injuries and substantial material damages can be the consequence.
a) Only approved personnel must carry out work on the system.
b) Keep unapproved personnel away from danger areas.
This manual is intended for the target groups listed below:
- The person who is responsible for the technical maintenance of this system.
- The person who operates the system every day and has been instructed.
Description
3.1 BDE-D Description
The BDE-D electronic operating unit is a convenient input and output unit for operating and programming control units in our door operators.
Logically arranged buttons allow intuitive operation of the door and navigation through the operator-specific menu structure. The LCD display with backlighting provides details and information on the door status using symbols and plain text.
There is a choice of several languages, which increases user-friendliness on the one hand and facilitates service interventions on the other.
The connection to the control units is made via the CAN bus.3.2 Identification
1 | Keypad with 6 keys | 8 | Navigation aid in the menu (scrollbar) |
2 | Navigation information | 9 | Menu lines (link to submenu) |
3 | LCD display | 10 | Slider control |
4 | Status displays (e.g. child-proof lock, re- duced opening width) | 11 | DIP-switch CAN-termination / selector BDE 1 or 2 |
5 | Operation mode (symbol and text) | 12 | Terminal board CAN bus |
6 | Title of main menu | 13 | Terminal board for external service lock |
7 | Cursor, active menu line |
Front view | Display | Rear view |
![]() |
![]() |
![]() |
BUILT-IN TYPE
Front view | Rear view | Side view |
![]() |
![]() |
![]() |
3.3 Connection to control unit
Connection on CAN-bus:1)
Plug in the connecting cable to the CAN-port (11) and connect it to the CAN-port on the STG (twistedpair cable).
Connect to the control unit…
The control unit has been connected (example).
No connection to the control unit.
Connect to the control unit…
1) Set the DIP-switches (S1-1, S1-2) before connecting to the CAN-port!
Technical Data
Supply voltage: | 24 VDC from CAN bus |
Connected load: | < 2 W |
Dimension of front panel: | 60 x 60 mm, adapted for Feller or Jung systems |
Dimension built-in type: | 92 x 44 mm |
Temperature range: | -20… +50°C |
Resolution of LCD display: | 112 x 64 pixels, with background light |
Key Functions
Key |
Function |
![]() |
Automatic operation |
![]() |
Hold-open operation |
![]() |
One-way operation |
![]() |
Locked |
![]() |
STA: reduced opening width DFA: manual operation |
![]() |
– Display for additional information – Access to parameter menu – Start procedure for service lock – Restart STG: press > 5 s – Restart Control Unit hardware: press > 12 s |
![]() |
Select the menu item and confirm entry |
![]() |
– Move down to select menu item – Slider control to the right to increase the value |
![]() |
– Move up to select menu item – Slider control to the left to decrease the value |
![]() |
Leave menu item, exit (without saving) |
NOTICE
Automatic return to the standard screen, 3 minutes after last input.
Important Notes
CAUTION
Inappropriate modification of the settings could impair the correct and safe function of the installation!
Access to parameters | ||
End customer or operator of the installation Key sequence: |
||
![]() |
![]() |
![]() |
NOTICE
Parameters or data that are not present in the control unit, or are only present as unknown values, will be indicated by a question mark and can be displayed in different ways depending on their type.
WITH SLIDER CONTROL
Select the mode of operation
Key | Operating mode STA Sliding Door |
Displayed Symbol |
![]() |
Automatic | ![]() |
![]() |
Continuously open | ![]() |
![]() |
One-way | ![]() |
![]() |
Manual | ![]() |
![]() |
Locked | ![]() |
![]() |
Reduced opening width | ![]() |
![]() |
Automatic | ![]() |
![]() |
Continuously open | ![]() |
![]() |
One-way | ![]() |
![]() |
Locked | ![]() |
![]() |
Manual operation | ![]() |
Carrying out functions
Restarting the Control Unit | ||
![]() |
Press > 5 s | |
![]() |
No | ![]() |
![]() |
Yes |
Restart Hardware | ||
![]() |
Press > 12 s | ![]() |
Connect to the control unit… | ||
![]() |
||
The control unit has been connected (example) | ||
![]() |
NOTICE
Only in Operation mode “Locked”.
Opening with SSK | |
![]() |
Select Operation mode “Locked”. |
![]() |
Press key “Locked” again to release SSK. |
NOTICE
Check directly the effect when parameters and configurations have been edited.
Opening while editing | |
![]() |
Press key “Continuously open” to release an opening. |
Reading out Information
Information about the door system, such as software version, door type, or servicing status, can be read on the display.
System Information | |
![]() |
Press approx. 2 s![]() |
![]() |
Browsing through information screens![]() |
![]() |
![]() |
![]() |
![]() |
NOTICE
Return to the standard screen by pressing the key or automatically after 20 s.
Fault indications
Fault indications | |
Any current operational faults in the drive system, will be displayed in the standard screen.![]() |
|
![]() |
Temporary return to the standard screen for 4 s. |
Primary / Secondary Installations | |
You can switch between the current fault of the Primary and Secondary drives. | |
![]() |
Browsing the fault screens![]() |
![]() |
Temporary return to the standard screen for 4 s, after browsing the fault screens. |
Lock control panel
NOTICE
Undesirable manipulation on the control unit by unauthorized persons, can be hindered in a simple manner.
Control lock via keypad | Displayed on LCD | ||
![]() |
Press the key sequence as shown. To disable, press the key sequence again. |
No settings can be made on the control unit. | ![]() |
![]() |
|||
![]() |
Electronic control lock | Displayed on LCD |
To activate the electronic control lock, open up the connection between J2 / 1-2 (refer to the connection diagram). | ![]() |
Connecting control lock
If a control lock is connected, the connection on the printed circuit board (PCB) must be broken out!
Parameter settings with slider controls
NOTICE
With the type “low energy”, the parameters can only be changed by qualified personnel.
The following example of the closing speed explains how to set the parameters of the door.
Closing speed example | ||||
Step | Key | Operation | Function |
Displayed on LCD |
1 | ![]() |
Press the keys in the order shown. | Access to the parameter at end cus- tomer level. | ![]() |
2 | ![]() |
Press the key 1x | In the Driving cycle menu, select the Closing speed menu item and confirm. | ![]() |
3 | ![]() |
Set the closing speed with the keys shown. | Select the desired speed in the Clos- ing speed menu item. | ![]() |
![]() |
Hold down the key to move continuously. | Increase/decrease the speed 0 = minimum 40 = maximum |
![]() |
|
![]() |
Decreasing the speed. | |||
4 | ![]() |
Press key 1x | Confirm the entry and save it in the STG. | |
5 | ![]() |
Press key 1x | Exit the menu item. |
Taking out of service and disposal
13.1 Decommissioning
NOTICE
After each temporary shutdown a new commissioning must be carried out.
When the system is taken out of service:
a) Disconnect the system from the mains supply.
b) Unplug from any existing battery.
13.2 Dismantling and disposal
NOTICE
All parts must be separated, sorted by the type of material, and disposed of. Refer to local regulations and guidelines.
The installation mainly consists of the following materials:
Metal components (aluminium, steel, and iron)
- Linking profiles, system leaf profiles, side profiles, various profiles, and reinforcement profiles.
- Gearbox, drive panel.
- Gear components and springs.
- Stainless steel casing, floor panel, and box recess for the floor installation.
- Various small parts like fittings, covers, optional spacers, and linking parts.
Glass
- Leaves and side panels.
Various electronic and electromechanical components
- Sensors.
- Control components and operator components.
- Batteries and rechargeable batteries.
Various plastics
- Rollers.
- Sealing profiles.
- Cable clips, coupling and linking parts.
- Casing of electromechanical components and sensors.
Documents / Resources
![]() |
record BDE-D Control Unit [pdf] User Manual 2V0_REC_102, 903109272, BDE-D Control Unit, BDE-D, Control Unit, Unit |