V5 5.0 Inch LCD Display Weather Station
“
Product Specifications:
- Time Format: 12/24 hour
- Perpetual Calendar: Up to Year 2099
- Day of Week Languages: English, German, Italian, French,
Spanish, Netherlands, Danish - Dual Alarm Clock: Weekdays/Weekends/Daily
- Snooze Time: 1-30 minutes or OFF
- Low Battery Indicator
- Weather Forecast
- Ice Alert
- Remote Sensor Temperature Alert Range Setting
- Change Trend Display
- Humidity Measurable Range: 20%RH – 95%RH
- Temperature & Humidity Display
- Wireless Outdoor Sensor:
- 3 Channels Selectable
- 433.92MHz RF Transmitting Frequency
- 60 Meter Transmission Range (Open Area)
- Power Supply:
- Weather Station: 2 x LR03 AAA size 1.5V Batteries
- Remote Sensor: 2 x LR6 AA size 1.5V Batteries
Product Usage Instructions:
Initial Setup:
- Open the main unit battery compartment cover.
- Insert 2 x 1.5V AAA size batteries observing polarity for
indoor temperature & humidity. - The main unit will start connecting to the outdoor remote
sensor. This process lasts up to 3 minutes. - Open the remote sensor battery compartment cover, select the
channel, insert 2 x 1.5V AA size batteries, and close the
cover. - Press the CH button to view data from different channels.
Manual Setting:
- To set the time format, press and hold the button for 2
seconds, then adjust using the buttons. - Press the button to confirm settings.
- Adjust values by pressing and holding the buttons.
- To set alarms, press the button to toggle between Alarm1 and
Alarm2 ON/OFF status.
Frequently Asked Questions (FAQ):
Q: How to change the language for the day of the week?
A: Use the manual setting instructions to navigate through
language options and select your preferred language.
Q: What does the ice alert feature do?
A: The ice alert feature warns you of potential icy conditions,
allowing you to take necessary precautions.
“`
V5 User Manuals
Features:
Time in oponal 12/24 hour format Perpetual Calendar Up to Year 2099 Day of week in 7 languages user selectable: English, German,
Italian, French, Spanish, Netherlands and Danish Dual Alarm clock can be set on weekdays / weekends and
daily Snooze me seng (1~30Minute or OFF) Low baery indicate Weather forecast Ice alert Remote sensor temperature alert range set Change trend display Humidity measurable range: 20%RH ~ 95%RH Temperature:
— Indoor temperature measurement ranges: -9.9°C (14.2°F) ~
50°C (122°F)
— Outdoor temperature measurement ranges: -40°C (-40°F) ~
70°C (158°F)
— Temperature alternavely in °C or °F Maximum /minimum value record of temperature and
humidity Wireless outdoor sensor:
–3 channels selectable
— 433.92MHz RF transming frequency — 60 meter transmission range in an open area Power supply:
Weather staon: Baery: 2 x LR03 AAA size 1.5V Remote sensor:
Baery: 2 x LR6 AA size 1.5V
V5 User Manuals Appearance descripon:
V5 User Manuals RX ATime BTrend of Air Pressure Changes CWeather forecast DRemote sensor temperature alert status symbol ERemote sensor temperature and humidity value FINDOOR temperature and humidity value GLight / snooze buon (Touch) HTrend of Remote sensor humidity variaon I Day of week JDate KBaery compartment cover LAlarm status indicator MOperang buons
TX A1: Remote sensor temperature A2: Emission symbols A3: Channel number A4: Remote sensor humidity A5: Remote sensor low baery indicate
B1: °C /°F unit transfer buon B2: Manual transmier buon B3: Channel switch
C1: Transmit indicang lamp C2: Baery compartment cover
V5 User Manuals
C3: Wall mounng hole C4: Stand cover C5: Baery compartment
Inial operaon:
Open the main unit baery compartment cover Insert 2 x 1.5V AAA size baeries observing polarity
Reference “+” and “” marks When you insert the baeries, all icons on the LCD will light up for 3 seconds, and you will hear a beep tone, then detect
indoor temperature & humidity. The main unit will now start to make a connecon to the outdoor remote sensor. This process lasts for a maximum of 3
minutes and will displayed by a flashing recepon antenna
symbol
in the upper right corner of the number of
channels. This moment, Open the remote Sensor baery compartment cover, push the channel switch to select the number of channels
to use, Insert 2 x 1.5V AA size baeries according to the correct
polarityReference “+” and “” marks. Press the “/°F”
buon to select the desired temperature unit, close the baery cover. It will create remote sensor connecons, press the CH buon to view the received data of different channels.
Manual me seing:
Press and hold the buon
for 2 seconds, the “12/24Hr”
starts to flash, and press and buons to set the ming format you want.
Press the buon
to confirm the item has been set and
V5 User Manuals
go to the next one, the sequence of seng items is as follows: 12/24HR HOUR MINUTE Format of DATE (D/M or M/D) YEAR MONTH DATE Language of WEEK Temperature Unit (°C/°F) Current weather
When adjusng the value, press and hold the or
buon to adjust quickly.
Press the buon
to confirm the last item to end the
seng procedures, then it will return to the normal mode. When the 12-hour format is selected, “PM” before the hour
indicates it is post meridiem.
The 7 languages that show week abbreviaons are listed
below:
F.Y.I.: If there is no valid operaon within 20 seconds, it will automacally return to normal me mode from the set mode.
Seng the daily alarms:
Press the buon, you can set Alarm1 and Alarm2 ON
V5 User Manuals
or OFF, symbol appear means that ALARM1 is ON, symbol
appear means that ALARM2 is ON, symbol or disappear means that Corresponding ALARM is OFF.
Press the buon to display the Alarm1 me on the LCD (5
seconds), press the buon again while Alarm1 me is displayed to show the Alarm2 me(5 seconds), press the buon
again once more while Alarm2 me is displayed to return to
the current me display. When Alarm1 me is displayed, press and hold the buon
for 2 seconds unl Hour of the Alarm1 me starts to flash, press the or buons to set the required Hour.
Press the buon
to confirm the item has been set and
go to the next one, the sequence of seng items is as follows: Hour of Alarm1 Minute of Alarm1 repeat period of Alarm1
Snooze me of Alarm1 When seng the repeat period, comply with the following
rules:
M-F: From Monday to Friday
S-S: From Saturday to Sunday
M-F S-S: From Monday to Sunday The snooze me can be set to 1-30 minutes or OFF, if “OFF” is
selected, it means that the snooze funcon is turned off. The Alarm2 me can be set according to the same method
above
F.Y.I.:
If there is no valid operaon within 20 seconds, it will
automacally return to normal me mode from the alarm me
set mode.
V5 User Manuals
When adjusng the value, press and hold the or buons to adjust connuously and quickly. The Alarm will sound for 2 minutes if you do not deacvate it by pressing any buon.
Turn OFF the alarm sound
When it’s ringing, press any buon except the to stop the Alarm sound. When it’s ringing, touch and hold the seconds to stop the Alarm sound.
key key for 2
Snooze funcon
When it’s ringing, touch the
key to acvate
snooze mode, when the set snooze me is over, it will ring
again.
RF Transmission Procedure
The main unit automacally starts receiving transmission from remote sensor for outdoor temperature & humidity aer baeries inserted. The remote sensor will automacally transmit temperature and humidity data to the main unit aer baeries inserted. If the main unit failed to receive transmission from remote
sensor (“- -.-“and “- -” display on the LCD), Press and hold the
CH buon for 2 seconds, RF icon
will be flashingthe
main unit will rescan the launch signal of the channel. The main unit receive remote signals of up to 3 channels,
press theCH buon to switch and display data of different
channels, when the symbol
appears, the data of
V5 User Manuals
different channels will be displayed automacally every 5 seconds.
Maximum / Minimum numerical value of memory
When the temperature and humidity are shown in the LCD, the main unit began to record temperature/ humidity maximum and minimum numerical value. Press the buon, the LCD will display maximum value
of temperature/ humidity. Press the buon again while the maximum values are displayed to show the minimum temperature and humidity. at the same me, there are “MAX” or “MIN” displayed on the LCD. The temperature and humidity maximum/minimum value will
will be recorded again aer pressing and hold buon for 3 seconds.. The memory value of the day will be automacally cleared at 0:00 every night.
Weather forecasng funcon
Warning: Please take the weather forecast from your local weather forecasng service into account as well as the forecast from your weather staon. If there are discrepancies between the informaon from your device and from the local weather forecasng service, please take the advice of the laer as authoritave. The weather forecast is calculated from evaluaon of fluctuaons in the barometric pressure and may deviate from the actual weather condions. The weather staon displays the following weather symbols:
V5 User Manuals
to 37.3°F). The ice alert funcon remains acve, but no sound alarm is issued.
Outdoor temperature alert
Acvate the Alert Funcon: Press the
buon to toggle
the outdoor temperature alert funcon ON or OFF. This seng
applies only to the currently displayed channel.
Switch Channels: To set the alert funcon for a different channel,
press the CH buon to select the desired channel.
Interpret Alert Symbols:
Symbol ON.
: Appears when the upper limit alert funcon is
Symbol
: Appears when the lower limit alert funcon is
ON.
No Symbols: Indicates that the outdoor temperature alert
funcon is OFF.
Press and hold
buon for 2 seconds, enter the outdoor
temperature upper limit or lower limit value seng mode, the
set item will flash, press the or buons to set the
value, then press the buon again to confirm the seng and move to the next one, press theCHbuon to set the value of other channels. When the outdoor temperature exceeds the set limit, the
temperature value and corresponding icon will flash. Each me the temperature is updated, if it sll exceeds the set limit, a beep reminder will sound.
V5 User Manuals
Trend displaying
The LCD display shows the current temperature, humidity, and barometric pressure trends. If no arrows are displayed, it indicates that the current trend is stable. Aer successfully connecng with the remote sensor, the main unit can display the outdoor temperature/ humidity and their change trends.
Background lighng
Touch the
key to turn on the backlight for 15
seconds.
Low baery warning
When a flashing symbol
appears near “INDOOR”, it
indicates that the weather staon’s baery is low. Please
replace it as soon as possible.
When a flashing symbol
appears near the channel
number, it indicates that the remote sensor’s baery is low.
Please replace it as soon as possible.
V5 User Manuals
Ice alert
The ice alert symbol
appears and flashes when the
remote sensor temperature is between -1.0°C and 2.9°C (30.2°F
Documents / Resources
![]() |
RADDY V5 5.0 Inch LCD Display Weather Station [pdf] User Manual V5, V5 5.0 Inch LCD Display Weather Station, 5.0 Inch LCD Display Weather Station, LCD Display Weather Station, Display Weather Station, Weather Station, Station |