QLT DIMCUBE 24 and Dimmable Interfaces
DIMCUBE 24 and DIMCUBE48 Interfaces
- Rated values at 24V refer to item DICUBE24N
- Rated values at 48V refer to item DICUBE48N
Technical Data
- Rated supply voltage
- 24 or 48V DC
- Max. main current
- 11A@24V 7A@48V
- Efficiency
- >96%
- Standby power
- <0,5W
- Digital input
- Push Button input ON/OFF Dimmer
- Analog Input
- 0_10
- Push line Max cable length
- 20 m con 0.5 – 2.5mmq
- Input selector
- DIP Switch
- Operating frequencies
- 250Hz PWM
- Max output current
- 11A@24V 7A@48V
- Max output power
- 264W@24V 336W@48V
- Protections
- Open load Short circuit, overload
- Connections
- Screw connectors 0.5..2.5mmq
- Operating temperature
- -10°C … +45°C
- TC point
- 60° tested on the label surface
- Storage temperature
- -15°C … +50°C
- Dimensions LxPxA
- 41x47x20 mm
- Weight
- 30g
- Protection degree
- IP 20
Synchro procedure
In the case of systems with more devices controlled by push-button, synchronization is achieved by holding the control for a long time until maximum light is reached on all devices.
State memory
Push button operation The dimmer memory is kept with a continuous power supply only
Safety note
Installation of this device may only be carried out by specialist staff. Switch off the mains supply before device connection Keep this document in a safe place Respect the safety and accident prevention regulations Dispose of it according to instructions.
Standard and Directives
2014/35/EU (LVD); 2014/30/EU (EMC); RoHs 2011/65/EU + 2015/863/EU (RoHs)EN 61347-2-13:2014 + A1:2017; EN 61347-1:2015 EN 55015:2019 + A11:2020 EN IEC 63000:2018
Areas of application
The device may only:
- be used for the applications specified.
- be used for safe installation in a dry and clean environment.
- be installed in such a way that access is only possible using a tool.
Dimensions (mm)
Frequently Asked Questions (FAQ)
Q: What should I do if the device does not power on?
A: Check the power supply connection and voltage compatibility. Ensure the current drawn is within the specified limits.
Q: How can I determine the model of my device?
A: The model can be found on the device label or in the user manual. Look for DICUBE24N for 24V and DICUBE48N for 48V.
Q: Is it safe to operate the device at different voltage levels?
A: No, always use the specified voltage (24V or 48V DC) to prevent damage to the device.
- Qualitron s.r.l. Via Dolomiti 15 20027 Rescaldina ( Milano ) Italy WWW.QLT.IT qlt@qlt.it
- Specifications subject to change without notice
Documents / Resources
![]() |