Qlima SC 6053 SET Air Conditioner With Quick Coupling
Product Specifications
- Model: S60xx
- Capacity: Varies based on BTU/t
- Refrigerants: R410A, R32
- Operation: Inverter split with manual operation
Safety Precautions
- Ensure the unit is used in accordance with the provided guidelines.
- Avoid unintended use or damage to the unit.
Unit Specifications and Features
- Operating Temperature: As specified
- Special Features: Manual operation (without remote control)
Care and Maintenance
Regularly clean and maintain the unit as per the maintenance instructions provided in the manual.
Troubleshooting
Refer to the troubleshooting section of the manual for guidance on resolving common issues.
Unit Components
Familiarize yourself with the different parts of the unit for better understanding and maintenance.
Connect Signal Cable
Follow the provided instructions for connecting the signal cable securely.
Disposal of Waste
Dispose of any waste generated during installation or maintenance responsibly.
Frequently Asked Questions
Q: How do I choose the right cable size for the unit?
A: Refer to the maximum current indicated on the unit’s nameplate to select the appropriate cable size.
Q: What should I do if there is a wiring issue?
A: Strictly follow the wiring diagram located on the back of the indoor unit’s front panel for correct wiring.
Q: How do I connect the signal wire to the unit?
A: Feed the signal wire through the designated slot and connect it according to the wiring diagram provided.
“`
SAFETY INSTRUCTIONS
Read Safety Precautions Before Operation and installation Incorrect installation due to ignoring instructions can cause serious damage or injury. The seriousness of potential dam- age or injuries is classified as either a WARNING or CAUTION.
WARNING
This symbol indicates the possibility of personnel injury or loss of life.
CAUTION
This symbol indicates the possibility of property damage or serious consequences.
WARNING
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by chil- dren without supervision(European Union countries).
This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabili- ties, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
WARNINGS FOR PRODUCT USE
• lf an abnormal situation arises (like a burning smell),
immediately turn off the unit and disconnect the power.
Call your dealer for instructions to avoid electric shock,
fire or injury.
• Do not insert fingers, rods or other objects into the air
inlet or outlet. This may cause injury, since the fan may be
rotating at high speeds.
• Do not use flammable sprays such as hair spray, lacquer or
paint near the unit. This may cause fire or combustion.
• Do not operate the air conditioner in places near or around
combustible gases. Emitted gas may collect around the
unit and cause explosion.
• Do not operate your air conditioner in a wet room such
as a bathroom or laundry room. Too much exposure to
water can cause electrical components to short circuit.
• Do not expose your body directly to cool air for a prolonged period of time.
• Do not allow children to play with the air conditioner.
Children must be supervised around the unit at all times.
• lf the air conditioner is used together with burners or
other heating devices, thoroughly ventilate the room to
avoid oxygen deficiency.
• In certain functional environments, such as kitchens, server
rooms, etc., the use of specially designed air-conditioning
units is highly recommended.
CLEANING AND MAINTENANCE WARNINGS
• Turn off the device and disconnect the power before
cleaning. Failure to do so can cause electrical shock.
• Do not clean the air conditioner with excessive amounts
of water.
• Do not clean the air conditioner with combustible cleaning
agents. Combustible cleaning agents can cause fire or
deformation.
90
CAUTION
• Turn off the air conditioner and disconnect the power if
you are not going to use it for a long time.
• Turn off and unplug the unit during storms.
• Make sure that water condensation can drain unhindered
from the unit.
• Do not operate the air conditioner with wet hands. This
may cause electric shock.
• Do not use device for any other purpose than its intended
use.
• Do not climb onto or place objects on top of the outdoor
unit.
• Do not allow the air conditioner to operate for long peri- ods of time with doors or windows open, or if the humidity
is very high.
ELECTRICAL WARNINGS
• Only use the specified power cord. lf the power cord is
damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to
avoid a hazard.
• Keep power plug clean. Remove any dust or grime that
accumulates on or around the plug. Dirty plugs can cause
fire or electric shock.
• Do not pull power cord to unplug unit. Hold the plug
firmly and pull it from the outlet. Pulling directly on the
cord can damage it, which can lead to fire or electric
shock.
• Do not modify the length of the power supply cord or use
an extension cord to power the unit.
• Do not share the electrical outlet with other appliances.
lmproper or insufficient power supply can cause fire or
electrical shock.
• The product must be properly grounded at the time of
installation, or electrical shock may occur.
• For all electrical work, follow all local and national wiring standards, regulations, and the lnstallation Manual.
4
91
Connect cables tightly, and damp them securely to prevent
external farces from damaging the terminal. lmproper
electrical connections can overheat and cause fire, and
may also cause shock. All electrical connections must be
made according to the Electrical Connection Diagram
located on the panels of the indoor and outdoor units.
• All wiring must be properly arranged to ensure that the
control board cover can close properly. lf the control
board cover is not closed properly, it can lead to corrosion
and cause the connection points on the terminal to heat
up, catch fire, or cause electrical shock.
• lf connecting power to fixed wiring, an all-pole disconnection device which has at least 3mm clearances in all poles,
and have a leakage current that may exceed 1 0mA, the
residual current device(RCD) having a rated residual operating current not exceeding 30mA, and disconnection
must be incorporated in the fixed wiring in accordance
with the wiring rules.
TAKE NOTE OF FUSE SPECIFICATIONS
The air conditioner’s circuit board (PCB) is designed with a
fuse to provide overcurrent protection. The specifications of
the fuse are printed on the circuit board ,such as
T3.15Al/250VAC, T5Al/250VAC, T3.15A/250VAC, T5A/250VAC,
T20A/250VAC, T30A/250VAC,etc.
NOTE: For the units using R32 or R290 refrigerant , only the
blast-proof ceramic fuse can be used.
UV-C lamp(Applicable to the unit contains an UV-C lamp
only)
This appliance contains a UV-C lamp. Please read the following instructions before opening the appliance.
1. Do not operate UV-C lamps outside of the appliance.
2. Appliances that are obviously damaged must not be
operated.
4
92
3. Unintended use of the appliance or damage to the
housing may result in the escape of dangerous UV-C
radiation. UV-C radiation may, even in small doses, cause
harm to the eyes and skin.
4. Before opening doors and access panels bearing the
ULTRAVIOLET RADIATION hazard symbol for the conducting USER MAINTENANCE, it is recommended to disconnect the power.
5. The UV-C lamp can not be cleaned, repaired and replaced.
6. UV-C BARRIERS bearing the ULTRAVIOLET RADIATION
hazard symbol should not be removed.
WARNING
This appliance contains an UV emitter. Do not stare at
the light source.
WARNINGS FOR PRODUCT INSTALLATION
1. lnstallation must be performed by an authorized
dealer or specialist. Defective installation can cause
water leakage, electrical shock, or fire.
2. lnstallation must be performed according to the
installation instructions. lmproper installation can cause
water leakage, electrical shock, or fire.
(In North America,installation must be performed
in accordance with the requirement of NEC and CEC by
authorized personnel only.)
3. Contact an authorized service technician for repair or
maintenance of this unit. This appliance shall be installed
in accordance with national wiring regulations.
4. Only use the included accessories, parts, and specified
parts for installation. Using non-standard parts can
cause water leakage, electrical shock, fire, and can cause
the unit to fail.
5. lnstall the unit in a firm location that can support the
unit’s weight. lf the chosen location cannot support the
unit’s weight, or the installation is not done properly,
the unit may drop and cause serious injury and damage.
4
93
6. lnstall drainage piping according to the instructions in
this manual. lmproper drainage may cause water
damage to your home and property.
7. For units that have an auxiliary electric heater, do not
install the unit within 1 meter (3 feet) of any
combustible materials.
8. Do not install the unit in a location that may be exposed
to combustible gas leaks. lf combustible gas accumulates
around the unit, it may cause fire.
9. Do not turn on the power until all work has been
completed.
10. When moving or relocating the air conditioner, consult
experienced service technicians for disconnection and
reinstallation of the unit.
11. How to instaIl the appliance to its support, please read
the information for details in “indoor unit
installation” and “outdoor unit installation” sections.
Note about Fluorinated Gasses(Not applicable to the unit
using R290 Refrigerant)
1. This air-conditioning unit contains fluorinated
greenhouse gasses. For specific information on the type
of gas and the amount, please refer to the relevant label
on the unit itself or the “Owner’s Manual – Product
Fiche“ in the packaging of the outdoor unit. (European
Union products only).
2. lnstallation, service, maintenance and repair of this unit
must be performed by a certified technician.
3. Product uninstallation and recycling must be performed
by a certified technician.
4. For equipment that contains fluorinated greenhouse
gases in quantities of 5 tonnes of CO² equivalent
or more, but of less than 50 tonnes of CO² equivalent, lf
the system has a leakdetection system installed, it must
be checked for leaks at least every 24 months.
5. When the unit is checked for leaks, proper
record-keeping of all checks is strongly recommended.
4
94
WARNING for Using R32/R290 Refrigerant
• When flammable refrigerant are employed, appliance
shall be stored in a well -ventilated area where the room
size corresponds to the room area as specifiec for operation.
For R32 frigerant models:
Appliance shall be installed, operated and stored in a
room with a floor area larger than 4m² . For R290 refrigerant models, appliance shall be installed, operated and
stored in a room with a floor area larger than:
<=9000Btu/h units: 13m2
>9000Btu/h and <=12000Btu/h units: 17m²
> 12000Btu/h and <=18000Btu/h units: 26m²
> 18000Btu/h and <=24000Btu/h units: 35m²
• Reusable mechanical connectors and flared joints are not
allowed indoors. (EN Standard Requirements).
• Mechanical connectors used indoors shall have a rate of
not more than 3g/year at 25% of the maximum allowable pressure. When mechanical connectors are reused
indoors, sealing parts shall be renewed. When flared
joints are reused indoors, the flare part shall be re-fabricated. (UL Standard Requirements)
• When mechanical connectors are reused indoors, sealing
parts shall be renewed. When flared joints are reused
indoors, the flare part shall be re-fabricated. (IEC Standard
Requirements)
• Mechanical connectors used indoors shall comply with ISO
14903.
European Disposal Guidelines
This marking shown on the product or its literature, indicates that waste electrical and
eletrical equipment should not be mixed with genera/ household waste.
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
4
95
This appliance contains refrigerant and other potentially hazardous materials. When disposing of
this appliance, the law requires special collection and treatment. Do not dispose of this product as
household waste or unsorted municipal waste.
When disposing of this appliance, you have the following options:
• Dispose of the appliance at designated municipal electronic waste collection facility.
• When buying a new appliance, the retailer will take back the old appliance free of charge.
• The manufacturer will take back the old appliance free of charge.
• Sell the appliance to certified scrap metal dealers.
G NOTE
Disposing of this appliance in the forest or other natural surroundings endangers your health and
is bad for the environment. Hazardous substances may leak into the ground water and enter the
food chain.
B UNIT SPECIFICATIONS AND FEATURES
Indoor unit display
NOTE: Different models have different front panels and display windows. Not all the display codes
describing below are available for the air conditioner you purchased. Please check the indoor display
window of the unit you purchased.
lllustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be
slightly different. The actual shape shall prevail.
NOTE: Room relative humidity less than 80%. lf the air conditioner operates in excess of this figure, the
surface of the air conditioner may attract condensation. Please sets the vertical air flow louver to its
maximum angle (vertically to the floor), and set HIGH fan mode.
To further optimize the performance of your unit, do the following:
• Keep doors and windows closed.
• Limit energy usage by using TIMER ON and TIMER OFF functions.
• Do not block air inlets or outlets.
• Regularly inspect and clean air filters.
A guide on using the infrared remote is not included in this literature package. Not all the functions
are available for the air conditioner, please check the indoor display and remote control of the unit you
purchased.
Other features
• Auto-Restart(some units)
lf the unit loses power, it will automatically restart with the prior settings once power has
been restored.
• Anti-mildew (some units)
When turning off the unit from COOL, AUTO (COOL), or DRY modes, the air conditioner will
continue operate at very low power to dry up condensed water and prevent mildew growth.
• Wireless Control (some units)
Wireless control allows you to control your air conditioner using your mobile phone and a wireless
connection. For the USB device access, replacement, maintenance operations must be carried out by
professional staff.
• Louver Angle Memory(some units)
When turning on your unit, the louver will automatically resume its farmer angle.
• Active Clean function(some units)
— The Active Clean Technology washes away dust when it adheres to the heat exchanger by
automatically freezing and then rapidly thawing the frost. A “pi-pi” sound will be heard.
The Active clean operation is used to produce more condensed water to improve the
cleaning effect, and the cold air will blow out. After cleaning, the internal wind wheel then
keeps operating with hot air to blow-dry the evaporator, this keeping the inside clean.
— When this function is turned on, the indoor unit display window appears “CL” , after 20 to
130 minutes, the unit will turn off automatically and cancel Active Clean function.
— For some units, the system will start hightemperature cleaning process, and the temperature
of air outlet is very high. Please keep away from it. And this would lead to the rising of the
room temperature.
• Breeze Away (some units)
This feature avoids direct air flow blowing on the body and make you feel indulging in silky coolness.
• Refrigerant Leakage Detection (some units)
The indoor unit will automatically display “ELOC “or flash LEDS (model dependent ) when it detects
refrigerant leakage.
• Sleep Operation
The SLEEP function is used to decrease energy use while you sleep (and don’t need the same
temperature settings to stay comfortable). This function can only be activated via remote control.
And the Sleep function is not available in FAN or DRY mode.
Press the SLEEP button when you are ready to go to sleep. When in COOL mode, the unit will
increase the temperature by 1 °c (2° F) after 1 hour, and will increase an additional 1 °c (2° F) after
another hour. When in HEAT mode, the unit will decrease the temperature by 1 °C (2° F) after
1 hour, and will decrease an additional 1 °c (2° F) after another hour.
The sleep feature will stop after 8 hours and the system will keep running with final situation.
Documents / Resources
![]() |
Qlima SC 6053 SET Air Conditioner With Quick Coupling [pdf] Instruction Manual SC 6053 SET Air Conditioner With Quick Coupling, SC 6053 SET, Air Conditioner With Quick Coupling, Conditioner With Quick Coupling, Quick Coupling, Coupling |