Qlima-LOGO

Qlima S 6035 Split Unit Air Conditioner

Qlima-S-6035-Split-Unit-Air-Conditioner-PRODUCT

Specifications

  • Model: Smart Kit (Wireless Module)
  • Compatibility: Compatible with specific appliance models
  • Connectivity: Wireless

PRODUCT USING INSTRUCTIONS

  • Precautions
    • Make sure to use only the SMART KIT (Wireless Module) provided by the manufacturer.
    • Installation, replacement, and maintenance operations should be carried out by professional staff.
  • Install the Smart Kit (Wireless Module)
    • Remove the protective cap of the smart kit (wireless module).
    • Open the front panel of the appliance and insert the smart kit into the reserved interface.
    • Stick the QR code packed with the Smart Kit to the side panel of the appliance for easy scanning by a mobile phone.
    • Alternatively, take a picture of the QR code and save it on your phone.
  • Network Configuration
    • Cautions: Follow these steps within 8 minutes after turning on the appliance.
    • Make sure your mobile phone is connected to the wireless network you want to use and forget any other networks.
    • Disconnect the power supply of the appliance.
    • Connect the power supply and press the LED DISPLAY or DO NOT DISTURB button seven times within 10 seconds.
    • When the appliance displays “AP”, it indicates that the wireless connection is in AP mode.
  • Download App
    • Search and download “Smart Life” from app stores or scan the provided QR code to download the app for further configuration.
    • Registration / Login / Password Retrieval
    • If you don’t have an app account, follow the registration process as described in the app.

FAQs

  • Q: Can I use a different wireless module with this appliance?
    • A: No, only use the SMART KIT (Wireless Module) provided by the manufacturer for compatibility and safety reasons.

SAFETY INSTRUCTIONS

Read Safety Precautions Before Operation and lnstallation
Incorrect installation due to ignoring instructions can cause serious damage or injury. The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION.

WARNING
This symbol indicates the possibility of personnel injury or loss of life.

CAUTION
This symbol indicates the possibility of property damage or serious consequences.

WARNING
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision(European Union countries).
This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

WARNINGS FOR PRODUCT USE

• lf an abnormal situation arises (like a burning smell), immediately turn off the unit and disconnect the power. Call your dealer for instructions to avoid electric shock, fire or injury.
• Do not insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since the fan may be rotating at high speeds.
• Do not use flammable sprays such as hair spray, lacquer or paint near the unit. This may cause fire or combustion.
• Do not operate the air conditioner in places near or around combustible gases. Emitted gas may collect around the unit and cause explosion.
• Do not operate your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit.
• Do not expose your body directly to cool air for a prolonged period of time.
• Do not allow children to play with the air conditioner. Children must be supervised around the unit at all times.
• lf the air conditioner is used together with burners or other heating devices, thoroughly ventilate the room to avoid oxygen deficiency.
• In certain functional environments, such as kitchens, server rooms, etc., the use of specially designed air-conditioning units is highly recommended.

CLEANING AND MAINTENANCE WARNINGS
• Turn off the device and disconnect the power before cleaning. Failure to do so can cause electrical shock.
• Do not clean the air conditioner with excessive amounts of water.
• Do not clean the air conditioner with combustible cleaning agents. Combustible cleaning agents can cause fire or deformation.

CAUTION
• Turn off the air conditioner and disconnect the power if you are not going to use it for a long time.
• Turn off and unplug the unit during storms.
• Make sure that water condensation can drain unhindered from the unit.
• Do not operate the air conditioner with wet hands. This may cause electric shock.
• Do not use device for any other purpose than its intended use.
• Do not climb onto or place objects on top of the outdoor unit.
• Do not allow the air conditioner to operate for long periods of time with doors or windows open, or if the humidity is very high.

ELECTRICAL WARNINGS

• Only use the specified power cord. lf the power cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
• Keep power plug clean. Remove any dust or grime that accumulates on or around the plug. Dirty plugs can cause fire or electric shock.
• Do not pull power cord to unplug unit. Hold the plug firmly and pull it from the outlet. Pulling directly on the cord can damage it, which can lead to fire or electric shock.
• Do not modify the length of the power supply cord or use an extension cord to power the unit.
• Do not share the electrical outlet with other appliances. lmproper or insufficient power supply can cause fire or electrical shock.
• The product must be properly grounded at the time of installation, or electrical shock may occur.
• For all electrical work, follow all local and national wiring standards, regulations, and the lnstallation Manual.

Connect cables tightly, and damp them securely to prevent external farces from damaging the terminal. lmproper electrical connections can overheat and cause fire, and may also cause shock. All electrical connections must be made according to the Electrical Connection Diagram located on the panels of the indoor and outdoor units.
• All wiring must be properly arranged to ensure that the control board cover can close properly. lf the control board cover is not closed properly, it can lead to corrosion and cause the connection points on the terminal to heat up, catch fire, or cause electrical shock.
• lf connecting power to fixed wiring, an all-pole disconnection device which has at least 3mm clearances in all poles, and have a leakage current that may exceed 1 0mA, the residual current device(RCD) having a rated residual operating current not exceeding 30mA, and disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.

TAKE NOTE OF FUSE SPECIFICATIONS

The air conditioner’s circuit board (PCB) is designed with a fuse to provide overcurrent protection. The specifications of the fuse are printed on the circuit board ,such as T3.15Al/250VAC, T5Al/250VAC, T3.15A/250VAC, T5A/250VAC,
T20A/250VAC, T30A/250VAC,etc.
NOTE: For the units using R32 or R290 refrigerant , only the blast-proof ceramic fuse can be used.
UV-C lamp(Applicable to the unit contains an UV-C lamp only)
This appliance contains a UV-C lamp. Please read the following instructions before opening the appliance.
1. Do not operate UV-C lamps outside of the appliance.
2. Appliances that are obviously damaged must not be operated.
3. Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation. UV-C radiation may, even in small doses, cause harm to the eyes and skin.
4. Before opening doors and access panels bearing the ULTRAVIOLET RADIATION hazard symbol for the conducting USER MAINTENANCE, it is recommended to disconnect the power.
5. The UV-C lamp can not be cleaned, repaired and replaced.
6. UV-C BARRIERS bearing the ULTRAVIOLET RADIATION hazard symbol should not be removed.

UNIT SPECIFICATIONS AND FEATURES

Indoor unit display
NOTE: Different models have different front panels and display windows. Not all the display codes describing below are available for the air conditioner you purchased. Please check the indoor display window of the unit you purchased.
lllustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different. The actual shape shall prevail.

Qlima-S-6035-Split-Unit-Air-Conditioner-FIG- (1)

when Fresh and UV-C lamp(if any) feature is activated(some units)
when defrost feature is activated.
when the unit is on.
when TIMER is set.
when Wireless Control feature is activated(some units)
Displays temperature, operation feature and error codes:
for 3 seconds when:
• TIMER ON is set (if the unit is OFF, remains on when TIMER ON is set )
• FRESH, UV-C lamp, SWING, TURBO, ECO,or SILE

for 3 seconds when:
• TIMER OFF is set
• FRESH, UV-C lamp, SWING, TURBO, ECO,or SILENCE feature is turned off
when defrosting
when 8°C heating feature is turned on(some units)
when Active Clean feature is turned on(For lnverter split type)
when unit is self-cleaning(For Fixed-speed type)
Operating temperature
When your air conditioner is used outside of the following temperature ranges, certain safety protection features may activate and cause the unit to disabl

NOTE: Room relative humidity less than 80%. lf the air conditioner operates in excess of this figure, the surface of the air conditioner may attract condensation. Please sets the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
To further optimize the performance of your unit, do the following:
• Keep doors and windows closed.
• Limit energy usage by using TIMER ON and TIMER OFF functions.
• Do not block air inlets or outlets.
• Regularly inspect and clean air filters.
A guide on using the infrared remote is not included in this literature package. Not all the functions are available for the air conditioner, please check the indoor display and remote control of the unit you purchased.
Other features
• Auto-Restart(some units)
lf the unit loses power, it will automatically restart with the prior settings once power has been restored.
• Anti-mildew (some units)
When turning off the unit from COOL, AUTO (COOL), or DRY modes, the air conditioner will continue operate at very low power to dry up condensed water and prevent mildew growth.
• Wireless Control (some units)
Wireless control allows you to control your air conditioner using your mobile phone and a wireless connection. For the USB device access, replacement, maintenance operations must be carried out by professional staff.
• Louver Angle Memory(some units) When turning on your unit, the louver will automatically resume its farmer angle.
• Active Clean function(some units)
— The Active Clean Technology washes away dust when it adheres to the heat exchanger by automatically freezing and the

The Active clean operation is used to produce more condensed water to improve the cleaning effect, and the cold air will blow out. After cleaning, the internal wind wheel then keeps operating with hot air to blow-dry the evaporator, this keeping the inside clean.
— When this function is turned on, the indoor unit display window appears “CL” , after 20 to 130 minutes, the unit will turn off automatically and cancel Active Clean function.
— For some units, the system will start hightemperature cleaning process, and the temperature of air outlet is very high. Please keep away from it. And this would lead to the rising of the room temperature.
• Breeze Away (some units)
This feature avoids direct air flow blowing on the body and make you feel indulging in silky coolness.
• Refrigerant Leakage Detection (some units)
The indoor unit will automatically display “ELOC “or flash LEDS (model dependent ) when it detects refrigerant leakage.
• Sleep Operation
The SLEEP function is used to decrease energy use while you sleep (and don’t need the same temperature settings to stay comfortable). This function can only be activated via remote control.
And the Sleep function is not available in FAN or DRY mode.
Press the SLEEP button when you are ready to go to sleep. When in COOL mode, the unit will increase the temperature by 1 °c (2° F) after 1 hour, and will increase an additional 1 °c (2° F) after another hour. When in HEAT mode, the unit will decrease the temperature by 1 °C (2° F) after 1 hour, and will decrease an additional 1 °c (2° F) after another hour.
The sleep feature will stop after 8 hours and the system will keep running with final situation.Qlima-S-6035-Split-Unit-Air-Conditioner-FIG- (2)

NOTE: For multi-split air condtioners, the following functions are not available: Active clean function, Silence feature, Breeze away function, Refrigerant leakage detection function and Eco feature.

Setting Angle of Air Flow
Setting vertical angle of air flow
While the unit is on, use the SWING/DIRECT button on remote control to set the direction (vertical angle) of airflow. Please refer to the Remote Control Manual for details.

NOTE ON LOUVER ANGLES

When using COOL or DRY mode, do not set louver at too vertical an angle for long periods of time. This can
cause water to condense on the louver blade, which will drop on your floor or furnishings.
When using COOL or HEAT mode, setting the louver at too vertical an angle can reduce the performance of
the unit due to restricted air flow.
NOTE: According to the relative standards requirement, please sets the vertical air flow louver to its
maximum angle under heating capacity test.
Setting horizontal angle of air flow
The horizontal angle of the airflow must be set manually. Grip the deflector rod (See Fig.B)
and manually adjust it to your preferred direction. For some units, the horizontal angle of the airflow can
be set by remote control. please refer to the Remote Control Manual.
Manual Operation(without remote)
CAUTION
The manual button is intended for testing purposes and emergency operation only. Please do not
use this function unless the remote control is lost and it is absolutely necessary. To restore regular
operation, use the remote control to activate the unit. Unit must be turned off before manual
operation.
To operate your unit manually:
1. Open the front panel of the indoor unit.
2. Locate the MANUAL CONTROL button on the right-hand side of the unit.
3. Press the MANUAL CONTROL button one time to activate FORCED AUTO mode.
4. Press the MANUAL CONTROL button again to activate FORCED COOLING mode.
5. Press the MANUAL CONTROL button a third time to turn the unit off.
6. Close the front panel.

Qlima-S-6035-Split-Unit-Air-Conditioner-FIG- (3)

NOTE: Do not move louver by hand. This will cause the louver to become out of sync. lf this occurs, turn off
the unit and unplug it for a few seconds, then restart the unit. This will reset the louver.
CAUTION
Do not put y our fingers in or near the blower and suction side of the unit. The high-speed fan inside the unit may cause injury.

Qlima-S-6035-Split-Unit-Air-Conditioner-FIG- (4)

CARE AND MAINTENANCE

Cleaning Your Indoor Unit
BEFORE CLEANING OR MAINTENANCE
ALWAYS TURN OFF YOUR AIR CONDITIONER SYSTEM AND DISCONNECT ITS POWER SUPPLY BEFORE CLEANING OR MAINTENANCE.

CAUTION
Only use a soft, dry cloth to wipe the unit clean. lf the unit is especially dirty, you can use a cloth soaked in warm water to wipe it clean.
• Do not use chemicals or chemically treated cloths to clean the unit
• Do not use benzene, paint thinner, polishing powder or other solvents to clean the unit. They can cause the plastic surface to crack or deform.
• Do not use water hotter than 40°C (104°F) to clean the front panel. This can cause the panel to deform or become discolor

Cleaning Your Air Filter
A clogged air conditioner can reduce the cooling efficiency of your unit, and can also be bad for your health. Make sure to clean the filter once every two weeks.

1. Lift the front panel of the indoor unit.
2. First press the tab on the end of filter to loosen the buckle, lift it up, then pull it towards yourself.
3. Now pull the filter out.
4. lf your filter has a small air freshening filter, unclip it from the larger filter. Clean this air freshening filter with a hand-held vacuum.
5. Clean the large air filter with warm, soapy water. Be sure to use a mild detergent.
6. Rinse the filter with fresh water, then shake off excess water.
7. Dry it in a cool, dry place, and refrain from exposing it to direct sunlight.
8. When dry, re-clip the air freshening filter to the larger filter, then slide it back into the indoor unit.
9. Close the front panel of the indoor unit.

Qlima-S-6035-Split-Unit-Air-Conditioner-FIG- (5)

CAUTION
Do not touch air freshening (Plasma) filter for at least 10 minutes after turning off the unit.

CAUTION
• Before changing the filter or cleaning, turn off the unit and disconnect its power supply.
• When removing filter, do not touch metal parts in the unit. The sharp metal edges can cut you.
• Do not use water to clean the inside of the indoor unit. This can destroy insulation and cause electrical shock.
• Do not expose filter to direct sunlight when drying. This can shrink the filter.panel to deform or become discolored.

Air Filter Reminders (Optional)

Air Filter Cleaning Reminder
After 240 hours of use, the display window on the indoor unit will flash “CL.” This is a reminder to clean your filter. After 15 seconds, the unit will revert to its previous display.
To reset the reminder, press the LED button on your remote control 4 times, or press the MANUAL CONTROL button 3 times. lf you don’t reset the reminder, the “CL” indicator will flash again when you restart the unit.

Air Filter Replacement Reminder
After 2,880 hours of use, the display window on the indoor unit will flash “nF.” This is a reminder to replace your filter. After 15 seconds, the unit will revert to its previous display.
To reset the reminder, press the LED button on your remote control 4 times, or press the MANUAL CONTROL button 3 times. lf you don’t reset the reminder, the “nF” indicator will flash again when you restart the unit.

CAUTION
• Any maintenance and cleaning of outdoor unit should be performed by an authorized dealer or a licensed service provider.
• Any unit repairs should be performed by an authorized dealer or a licensed service provid

Maintenance – Long Periods of Non-Use
lf you plan not to use your air conditioner for an extended period of time, do the following:

TROUBLESHOOTING

SAFETY PRECAUTIONS
lf ANY of the following conditions occurs, turn off your unit immediately!
• The power cord is damaged or abnormally warm
• You smell a burning odor
• The unit emits loud or abnormal sounds
• A power fuse blows or the circuit breaker frequently trips
• Water or other objects fall into or out of the unit
DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED SERVICE PROVIDER IMMEDIATELY!

Common Issues
The following problems are not a malfunction and in most situations will not require repairs.

Step 1: Select installation location
Before installing the indoor unit, you must choose an appropriate location. The following are
standards that will help you choose an appropriate location for the unit.
Proper installation locations meet the following standards:
• Good air circulation
• Convenient drainage
• Noise from the unit will not disturb other people
• Firm and solid-the location will not vibrate
• Strong enough to support the weight of the unit
• A location at least one meter from all other electrical devices (e.g., TV, radio, computer)
DO NOT install unit in the following locations:
• Near any source of heat, steam, or combustible gas
• Near flammable items such as curtains or clothing
• Near any obstacle that might black air circulation
• Near the doorway
• In a location subject to direct sunlight
G
NOTE ABOUT WALL HOLE
lf there is no fixed refrigerant piping: While choosing a location, be aware that you should leave ample room for a wall hole (see Drill wall hole for connective piping step) for the signal cable and refrigerant piping that connect the indoor and outdoor units. The default position for all piping is the right side of the indoor unit (while facing the unit). However, the unit can accommodate piping to bath the left and right.

Refer to the following diagram to ensure proper distance from walls and ceiling:
Step 2: Attach mounting plate to wall
The mounting plate is the device on which you will mount the indoor unit.
• Remove the screw that attaches the mounting plate to the back of the indoor unit.

• Secure the mounting plate to the wall with the screws provided. Make sure that mounting plate is
flat against the wall.
G
NOTE FOR CONCRETE OR BRICK WALLS
lf the wall is made of brick, concrete, or similar material, drill 5mm-diameter (0.2in-diameter)
holes in the wall and insert the sleeve anchors provided. Then secure the mounting plate to the
wall by tightening the screws directly into the clip anchors.

Step 3: Drill wall hole for connective piping
1. Determine the location of the wall hole based on the position of the mounting plate. Refer to
Mounting Plate Dimensions.
2. Using a 65mm (2.5in) or 90mm(3.54in) (depending on models )care drill, drill a hole in the wall. Make
sure that the hole is drilled at a slight downward angle, so that the outdoor end of the hole is lower
than the indoor end by about 5mm to 7mm (0.2-0.275in). This will ensure proper water drainage.
3. Place the protective wall cuff in the hole. This protects the edges of the hole and will help seal it
when you finish the installation process.
CAUTION
When drilling the wall hole, make sure to avoid wires, plumbing, and other sensitive components.
MOUNTING PLATE DIMENSIONS
Different models have different mounting plates. For the different customization requirements, the
shape of the mounting plate may be slightly different.
See Type A and Type B for example:
Wall
Indoor Outdoor
Correct orientation of mounting plate

Documents / Resources

Qlima S 6035 Split Unit Air Conditioner [pdf] Instruction Manual
S 6035, S 60XX 25, S 6035 Split Unit Air Conditioner, S 6035, Split Unit Air Conditioner, Unit Air Conditioner, Air Conditioner, Conditioner

References

Leave a comment