MS-AC 5001 Mini Split Unit Air Conditioner
MS-AC 5001
IMPORTANT COMPONENTS
- Hose
- Handle
- Control panel
- Outdoor unit air outlet
- Indoor unit air outlet
- Indoor unit air inlet
- Outdoor unit air inlet
- Power cord
1. READ THE DIRECTIONS FOR USE FIRST.
2. IN CASE OF ANY DOUBT, CONTACT YOUR DEALER.
WHAT’S INCLUDED
- Outside bracket
- M6 Screw
- Gasket of M6 screw
- Protection sleeve
- Drain hose
- Shockproof rubber dampers
- Inside bracket
- Hand screw
Diagrams for illustrative purposes only
Dear Sir, Madam,
Congratulations on the purchase of this appliance. You have acquired a high quality
appliance that will provide you with many years of pleasure, on condition that you use it
responsibly. Reading these instructions for use before operating the appliance will optimise
its life span. We wish you comfort with the new appliance.
Yours sincerely,
PVG Holding B.V.
Customer service department
SAFETY INSTRUCTIONS
Read this user manual carefully before using the appliance and keep it for future reference.
Install this appliance only when it complies with local/national legislation, ordinances and standards. This appliance is intended to be used as an air conditioner in residential houses and is only suitable for use in dry locations, in a caravan, in normal household conditions, indoors in living room, kitchen and garage.
IMPORTANT
- Never use the appliance with a damaged power cord, plug, cabinet or control
panel. Never trap the power cord or allow it to come into contact with sharp
edges. - The installation must be completely in accordance with local regulations,
ordinances and standards. - The appliance is suitable exclusively for use in dry places, indoors.
- Check the main voltage. This appliance is suitable exclusively for earthed sockets –
connection voltage 220-240 Volt/ 50 Hz. - The appliance MUST always have an earthed connection. You may absolutely not
connect the appliance if the power supply is not earthed. - The plug must always be easily accessible when the appliance is connected.
- Read these instructions carefully and follow the directions
Before connecting the appliance, check that:
- The connection voltage corresponds to that on the type plate.
- The socket and power supply are suitable for the appliance.
- The plug on the cable fits the socket.
- The appliance is on a stable and flat surface.
- A distance of 50cm should be left between the appliance and other objects from front side
and 20cm should be left between the appliance and other objects from left and right sides.
Have the electrical installation checked by a recognized expert if you are not sure that everything
is in order.
- This appliance is a safe appliance, manufactured in accordance with CE safety standards.
Nevertheless, as with every electrical appliance, exercise caution when using it. - Never cover the air inlets and outlets.
- Empty the water reservoir through the water drain before moving it.
- Never allow the appliance to come into contact with chemicals.
- Do not insert objects into the openings of the appliance.
- Never allow the appliance to come into contact with water. Do not spray the appliance with
water or submerge it as this may cause a short circuit. - Always take the plug out of the socket before cleaning or replacing the device or a part of
the device. - NEVER connect the device with the aid of an extension cable. If a suitable, earthed socket is
not available, have one fitted by a recognised electrician. - Always consider the safety of children in the vicinity of this device, as with every electrical
device. - Always have any repairs – beyond regular maintenance – carried out by a recognized service
engineer. Failure to do so may lead to invalidation of the guarantee. - Always take the plug out of the socket when the appliance is not in use.
- If the power cable is damaged, it must be replaced by the manufacturer, its customer service
department or persons with comparable qualifications in order to prevent danger. - This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety. - Children should be supervised to ensure that they do not play with the appliance.
- This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if they
have been given supervision or instruction concerning use of the appliance in a safe way
and understand the hazards involved. - Children shall not play with the appliance.
- Cleaning and user maintenance shall not be made by children without supervision.
ATTENTION!
- Never seal the room – where this appliance will be used – completely airtight.
This will prevent under pressure in this room. Under pressure can disrupt the safe
operation of geysers, ventilation systems, ovens, etc. - Failing to follow the instructions may lead to nullification of the guarantee on this
device.
Specific information regarding appliances with R290 refrigerant gas.
- Thoroughly read all of the warnings.
- When defrosting and cleaning the appliance, do not use any tools other than those recommended by the manufacturing company.
- The appliance must be placed in an area without any continuously sources of ignition (for
example: open flames, gas or electrical appliances in operation). - Do not puncture and do not burn.
- This appliance contains X g of R290 refrigerant gas.
- R290 is a refrigerant gas that complies with the European directives on the environment. Do
not puncture any part of the refrigerant circuit. Be aware the refrigerants may not contain an odour. - If the appliance is installed, operated or stored in a nonventilated area, the room must
be designed to prevent to the accumulation of refrigerant leaks resulting in a risk of fire
or explosion due to ignition of the refrigerant caused by electric heaters, stoves, or other
sources of ignition. - The appliance must be stored in such a way as to prevent mechanical failure.
- Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued by an accredited organization that ensures competence in handling refrigerants according to a specific evaluation recognized by associations in the industry.
- Repairs must be performed based on the recommendation from the manufacturing company.
Maintenance and repairs that require the assistance of other qualified personnel must be
performed under the supervision of an individual specified in the use of flammable refrigerants.
Appliances shall be installed, operated and stored in a room with a floor area larger than
4 m2. The appliance shall be stored in a well-ventilated area where the room size corr
sponds to the room area as specified for operation.
Explanation of symbols displayed on the unit (For the unit adopts R32/R290 Refrigerant only): |
||
|
WARNING: This symbol shows that this appliance used a flammable refrigerant. If the refrigerant is leaked |
|
|
CAUTION: This symbol shows that the installation manual should be |
|
|
CAUTION: This symbol shows that the installation manual should be |
|
|
CAUTION:
This symbol shows that the technical manual should be read |
INSTRUCTIONS FOR REPAIRING APPLIANCES
CONTAINING R290
1 GENERAL INSTRUCTIONS
This instruction manual is intended for use by individuals possessing adequate backgrounds of
electrical, electronic, refrigerant and mechanical experience.
1.1 Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are
necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system,
the following precautions shall be complied with prior to conducting work on the system.
1.2 Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable
gas or vapour being present while the work is being performed.
1.3 General work area
All maintenance staff and others working in the local area shall be instructed on the nature of
work being carried out. Work in confined spaces shall be avoided. The area around the workspace
shall be sectioned off. Make sure that the conditions within the area have been made safe by
control of flammable materials.
1.4 Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work,
to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak
detection equipment being used is suitable for use with flammable refrigerants, i.e. nonsparking,
adequately sealed or intrinsically safe.
1.5 Presence of fire extinguisher
lf any hotwork is to be conducted on the refrigeration equipment or any associated parts,
appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2
fire extinguisher adjacent to the charging area.
1.6 No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any
pipe work that contains or has contained flammable refrigerant shall use any sources of ignition
in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources,
including cigarette smoking, should be kept sufficiently far away from the site of installation,
repairing, removing and disposal, during which flammable refrigerant can possibly be released
to the surrounding space. Prior to work taking place, the area around the equipment is to be
surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs
shall be displayed.
1.7 Ventilated area
Make sure that the area is in the open or that it is adequately ventilated before breaking into
the system or conducting any hot work. A degree of ventilation shall continue during the period
that the work is carried out. The ventilation should safely disperse any released refrigerant and
preferably expel it externally into the atmosphere.
1.8 Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose and to the
correct specification. At all times the manufacturer’s maintenance and service guidelines shall
be followed. lf in doubt consult the manufacturer’s technical department for assistance. The
following checks shall be applied to installations using flammable refrigerants: – the charge size
is in accordance with the room size within which the refrigerant containing parts are installed.
- The ventilation machinery and outlets are operating adequately and are not obstructed.
- If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the
presence of refrigerant; - Marking to the equipment continues to be visible and legible. Markings and signs that are
illegible shall be corrected. - Refrigeration pipe or components are installed in a position where they are unlikely to be
exposed to any substance which may corrode refrigerant containing components, unless the
components are constructed of materials which are inherently resistant to being corroded or
are suitably protected against being so corroded.
1. 9 Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and component
inspection procedures. lf a fault exists that could compromise safety, then no electrical supply shall be
connected to the circuit until it is satisfactorily dealt with. lf the fault cannot be corrected immediately
but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be
reported to the owner of the equipment so all parties are advised. Initial safety checks shall include:
- that capacitors are discharged: this shall be done in a safe manner to avoid possibility of
sparking; - that there no live electrical components and wiring are exposed while charging, recovering or
purging the system. - that there is continuity of earth bonding.
2 REPAIRS TO SEALED COMPONENTS
2.1 During repairs to sealed components, all electrical supplies shall be disconnected from the
equipment being worked upon prior to any removal of sealed covers, etc. lf it is absolutely
necessary to have an electrical supply to equipment during servicing, then a permanently
operating form of leak detection shall be located at the most critical point to warn of a
potentially hazardous situation.
2.2 Particular attention shall be paid to the following to ensure that with working on electrical
components, the casing is not altered in such a way that the level of protection is affected. This
shall include damage to cables, excessive number of connections, terminals not made to original
specification, damage to seals, incorrect fitting of glands, etc.
Ensure that the appliance is mounted securely.
Ensure that seals or sealing materials have not degraded such that they no longer serve the
purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in
accordance with the manufacturer’s specifications.
NOTE The use of silicon sealant may inhibit the effectiveness of some types of leak detection
equipment. lntrinsically safe components do not have to be isolated prior to working on them.
3 REPAIR TO INTRINSICALLY SAFE COMPONENTS
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that
this will not exceed the permissible voltage and current permitted tor the equipment in use.
lntrinsically safe components are the only types that can be worked on while live in the presence
of a flammable atmosphere. The test appliance shall be at the correct rating.
Replace components only with parts specified by the manufacturer. Other parts may result in the
ignition of refrigerant in the atmosphere from a leak.
4 CABLING
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp
edges or any other adverse environmental effects. The check shall also take into account the
effects of aging or continua! vibration from sources such as compressors or fans.
5 DETECTION OF FLAMMABLE REFRIGERANTS
Under no circumstances shall potentially sources of ignition be used in the searching for or
detection of refrigerant leaks. A halide torch (or any other detector using a naked flame} may not
be used.
6 LEAK DETECTION METHODS
The following leak detection methods are deemed acceptable for systems containing flammable
refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the
sensitivity may not be adequate, or may need recalibration. (Detection equipment shall be
calibrated in a refrigerant-free area.)
Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant
used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and
shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 %
maximum} is confirmed.
Leak detection fluids are suitable for use with most refrigerants but the use of detergents
containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode
the copper pipework.
lf a leak is suspected, all open flames shall be removed/extinguished.
lf a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be
recovered from the system, or isolated (by means of shut off valves} in a part of the system
remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both
before and during the brazing process.
7 REMOVAL AND EVACUATION
When breaking into the refrigerant circuit to make repairs – or for any other purpose –
conventional procedures shall be used. However, it is important that good practice is followed
since flammability is a consideration. The following procedure shall be adhered to: remove
refrigerant; purge the circuit with inert gas; evacuate; purge again with inert gas; open the
circuit by cutting or brazing.The refrigerant charge shall be recovered into the correct recovery
cylinders. The system shall be “flushed” with OFN to render the appliance safe. This process may
need to be repeated several times. Compressed air or oxygen shall not be used for this task.
Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill
until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a
vacuum. This process shall be repeated until no refrigerant is within the system.
When the final OFN charge is used, the system shall be vented down to atmospheric pressure to
enable work to take place. This operation is absolutely vital if brazing operations on the pipework
are to take place. Ensure that the outlet tor the vacuum pump is not close to any ignition sources
and there is ventilation available.
8 CHARGING PROCEDURES
In addition to conventional charging procedures, the following requirements shall be followed.
Ensure that contamination of different refrigerants does not occur when using charging
equipment. Hoses or lines must be as short as possible to minimise the amount of refrigerant
contained in them. Cylinders shall be kept upright. Ensure that the refrigeration system is earthed
prior to charging the system with refrigerant. Label the system when charging is complete (if not
already). Extreme care shall be taken to not overfill the refrigeration system. Before recharging
the system it shall be pressure tested with OFN. The system shall be leak tested on completion of
charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving
the location.
9 DECOMMISSIONING
Before carrying out this procedure, it is essential that the technician is completely
familiar with the equipment and all its detail. lt is recommended that all refrigerants are
recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be
taken in case analysis is required prior to re-use of reclaimed refrigerant. lt is essential that 4 GB
electrical power is available before the task is commenced.
a) Become familiar with the equipment and its operation.
b) lsolate system electrically.
c) Before attempting the procedure, ensure that: mechanical handling equipment is
available, if required, for handling refrigerant cylinders;
d) All personal protective equipment is available and being used correctly; the recovery
process is supervised at all times by a competent person;
e) recovery equipment and cylinders conform to the appropriate standards.
f) Pump down refrigerant system, if possible. lf a vacuum is not possible, make a manifold
so that refrigerant can be removed from various parts of the system. Make sure that
cylinder is situated on the scales before recovery takes place.
i) Start the recovery appliance and operate in accordance with manufacturer’s instructions.
j) Do not overfill cylinders (No more than 80 % volume liquid charge).
k) Do not exceed the maximum working pressure of the cylinder, even temporarily.
l) When the cylinders have been filled correctly and the process completed, make sure
that the cylinders and the equipment are removed from site and all isolation valves on
the equipment are closed off.) Recovered refrigerant shall not be charged into another
refrigeration system unless it has been cleaned and checked.
10 LABELLING
Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant.
The label shall be dated and signed. Ensure that there are labels on the equipment stating the
equipment contains flammable refrigerant.
11 RECOVERY
When removing refrigerant from a system, either for servicing or decommissioning, it is
recommended that all refrigerants are removed safely. When transferring refrigerant into
cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that
the correct number of cylinders for holding the total system charge are available. All cylinders to
be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special
cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve
and associated shut-off valves in good working order. Empty recovery cylinders are evacuated
and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions concerning the
equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In
addition, a set of calibrated weighing scales shall be available and in good working order. Hoses
shall be complete with leak-free disconnect couplings and in good condition. Before using the
recovery appliance, check that it is in satisfactory working order, has been properly maintained
and that any associated electrical components are sealed to prevent ignition in the event of a
refrigerant release. Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery
cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery
appliances and especially not in cylinders.
lf compressors or compressor oils are to be removed, ensure that it has been evacuated to an
acceptable level to make sure that flammable refrigerant does not remain within the lubricant.
The evacuation process shall be carried out prior to returning the compressor to the suppliers.
Only electric healing to the compressor body shall be employed to accelerate this process. When
oil is drained from a system, it shall be carried out safely.
B INSTALLATION OF THE APPLIANCE
1. Unpack the appliance and accessories and check that the hose between the indoor and outdoor
unit is properly connected. Also check whether the condensation drain has a rubber cover.
Finally, check whether the accessories are complete.
2.1 Install the accessories as shown in the picture. Connect the outer bracket
to the support block and the inner bracket by tightening the M6 screws.
This is how to form the carrying handle.
2.2 Place the shockproof rubber dampers on the back of the outdoor unit.
2.3 Install the bracket as shown in the figure below. Install the indoor and outdoor units on the
bracket to fix the two parts. To secure the appliances to the bracket, tighten the M6 screws
in the appropriate holes.
2.4 Install the indoor unit on the bracket and tighten the bracket properly.Next, wrap the
protection sleeve on the hose between the outdoor and indoor unit (See the illustration
below).
2.5 Install the complete appliance in the caravan window and tighten the bracket properly.
2.6 the drain hose must always be installed on the outdoor unit. If this is not done, the tank will
fill up and the appliance will stop until the tank is emptied.
C OPERATION OF CONTROL PANEL
1. Power
Press this key to turn the appliance on and off.
When the appliance is turned on, the temperature is set to 22ºC by default. The temperature
sensor measures the ambient temperature and if exceeds 22ºC, the outdoor unit starts to work
to bring the temperature down. If the ambient temperature already below 22ºC, then the outdoor
unit does not start.
2. Mode
Press this key to select cooling, fan, dehumidification modes;
In standby/turned on mode, by pressing this key for 3 seconds to set timing on/off.
3. Temperature / time adjustment
In cooling mode, press the key to increase or decrease the temperature, the setting temperature
adjustable from 16~30ºC;
In timer mode, press the key to adjust time to turn on/turn off the appliance.
Press Up/Down key at the same time to transfer between ºC and ºF.
4. Fan speed
Press the key to choose low/high fan speed.
5. Sleep mode
Whilst within sleep mode you can set the desired temperature. The appliance will work towards
this temperature, but reduces noise and light from every source. This means a low ventilation
speed and a lowered compressor noise level. Over the next 8-10 hours the appliance will further
reduce its noise meaning temperature levels can increase. After this time the appliance will shut
off.
6. Display window
Check temperature and time from this window.
7. Swing
Press fan speed and sleep mode key at the same time to turn on/off swing function.
D MAINTENANCE
DECLARATION:
1) Ensure the appliance is unplugged before maintenance.
2) Do not use gasoline or other chemicals to clean the appliance
3) Do not wash the appliance directly;
4) If the appliance is damaged, please contact the dealer or repair shop.
CLEANING
CAUTION: Unplug the power cord before cleaning the maintenance.
1. AIR FILTER
- It is important to regularly remove the dust from the filter.
- Remove the filter as shown in the picture below.
- Clean the filter with tap water and / or a vacuum cleaner to remove any dirty from the filter.
- Do not use water hotter than 40°C for cleaning and do not expose the filter to the sun.
- Make sure the filter has dried before putting it back in the appliance.
2. CLEAN THE APPLIANCE’S SURFACE
- First clean the surface with a neutral detergent and wet cloth
- Then dry the appliance thoroughly with a dry cloth.
- Do not allow water or deterrent to enter the appliance.
- Do not clean the appliance with an aggressive cleaning agent and/or petrol.
STORAGE
If you are planning to store the appliance without using it for a long time, please remove the
drain cover from the drain hole at the bottoms both of indoor unit and outdoor unit, and drain all
the condensation water appropriately in available place.
- Remove the appliance from the window.
- Remove the rubber seal from the indoor unit and outdoor unit, drain the condensate water.
- Let it running in fan mode to make the internal parts dry.
- Turn off the appliance and pull down the plug.
- Wash the filter, then install.
- Remove all the brackets on the appliance, install the brackets of the indoor unit on the outdoor
unit, assemble as shown in the figure below, and then store the appliance against the wall. - Store the appliance in a cool and dry place.
- We recommend to put the appliance back in its packaging when you store it. This prevents
dirt and dust from collecting on the appliance.
E WIFI SETUP AND SMART FEATURES
WIFI SETUP
BEFORE YOU START
- Ensure the router provides a standard 2.4ghz connection.
- If the router is dual band ensure that both networks have different network names (SSID). The
provider of this router / Internet service provider will be able to provide advice specific to the
router. - Place the appliance as close as possible to the router during setup.
- Once the app has been installed on your phone, turn off the data connection, and ensure your
phone is connected to your router via wifi.
DOWNLOAD THE APP TO YOUR PHONE
• Download the ”SMART LIFE” app, from your chosen app store, using the
QR codes below, or by searching for the app in your chosen store.
CONNECTION METHODS AVAILABLE FOR SETUP
• The appliance has two different setup modes, Quick Connection and AP (Access Point). The
quick connection is a quick and simple way to set the appliance up. The AP connection uses
a direct local wifi connection between your phone and the appliance to upload the network
details.
• In Standby mode press and hold the fan button for 3 seconds (until you hear a bleep) to
enter the wifi connection mode.
• Please make sure the appliance is in the correct wifi connection mode for the connection
type you are attempting, the flashing of the wifi light on the appliance will indicate this.
Connection Type Frequency of Flashes Frequency of Flashes
Quick Connection Flashes twice per second
AP (Access Point) Flashes once per three seconds
CHANGING BETWEEN CONNECTION TYPES
To change the appliance between the two wifi connection modes, hold the fan button
for 3 seconds.
F SMART HOME WIFI CONNECTION GUIDE
INSTALL APP
Download the “Smart life” app from the Play Store (Android) or App Store (iOS).
REGISTER
If you do not have a Smarter Home account, register or sign in with a verification code sent by SMS.
To register:
1. Tap to enter registration page
2. The system automatically recognizes your country/area. It is also possible to select the
country code manually. Enter a mobile phone number/ email address and tap “Next”.
3.
4. If you choose the mobile phone number option, then enter the verification code in the
message sent to you by SMS. Set a password as prompted and press “Confirm” to finish the
registration.
ADD APPLIANCE THROUGH NETWORK
1. Turn the appliance on, when the appliance is in standby mode, press the “FAN”button for 3
seconds to enter Wifi-connect mode.
2. Open Smart Home app and tap “+” in the upper right to add a new
appliance through the network.
3. Ensure that the appliance’s indicator light rapidly flashes (2 times per second) and tap
“Confirm light is rapidly flashing”.
4. Select Wi-Fi network (note: network must be 2.4 Ghz band) and enter
the password .The appliance will commence the pairing process and connect to the app.
5. After successfully configuring the appliances the AC will be shown on the
smart home page. Tap to enter its control page.
G TROUBLE SHOOTING GUIDE
Do not repair or disassemble the appliances. Unqualified repair will invalidate the warranty and
may lead to failure, causing injuries and property damage. Only use it as directed in this user
manual and only perform operations advised here.
If problems not listed in the table occur or recommended solutions do not work, please contact
the service centre.
H ERROR CODE LIST
If the appliance does not work or works insufficiently:
Check if an error code is visible in the display, refer to the code table for a solution. If no error
code is visible in the display, go through the error table for a possible solution.
I FUSE PARAMETERS
Voltage: 250 V
Current: 3,15 A
Type : T
J WASTE DISPOSAL
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection
facilities. Contact your local government for information regarding the collection systems
available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can
leak into the groundwater and get into the food chain, damaging your health and well-being.
When replacing old appliances with new once, the retailer is legally obligated to take back your
old appliance for disposal at least for free of charge. Do not throw batteries into the fire, where
they can explode or release dangerous liquids. If you replace or destroy the remote control,
remove the batteries and throw them away in accordance with the applicable regulations
because they are harmful to the environment.
Environmental information: This equipment contains fluorinated greenhouse gases covered by
the Kyoto Protocol. It should only be serviced or dismantled by professional trained personnel.
This equipment contains R290 refrigerant in the amount as stated in the table above. Do not vent
R290 into atmosphere: R290, is a fluorinated greenhouse gas with a Global Warming Potential
(GWP) = 3.
Distributed in Europe by PVG Holding B.V.
For alle yderligere oplysninger eller ved eventuelle problemer med apparatet henvises til www.qlima.com eller det lokale Kundecenter (T: +45 77
34 33 30).
PVG Holding BV – Kanaalstraat 12 C – 5347 KM Oss – the Netherlands
P.O. Box 96 – 5340 AB Oss – the Netherlands
Documents / Resources
![]() |
Qlima MS-AC 5001 Mini Split Unit Air Conditioner [pdf] Instruction Manual MS-AC 5001 Mini Split Unit Air Conditioner, MS-AC 5001, Mini Split Unit Air Conditioner, Unit Air Conditioner, Air Conditioner, Conditioner |