To install and operate your FILL-RITE FR20V Piston Hand-Operated Fuel Transfer Pump, follow these general steps based on standard piston pump procedures:
Installation:- Prepare the Suction Pipe: Apply PTFE tape or a fuel-compatible sealant to the threads of the suction pipe. Screw the pipe into the bottom of the pump body.
- Adjust Pipe Length: Extend the telescoping suction pipe so it reaches approximately 3 inches from the bottom of your fuel tank or drum.
- Mount the Pump: Insert the suction pipe into the tank opening. Screw the pump's bung adapter (usually 2" NPT) into the tank bung until it is hand-tight and secure.
- Attach the Hose: Apply sealant to the hose threads and screw the hose into the discharge outlet on the pump head.
- Prime the Pump: Piston pumps are generally self-priming. Begin by moving the handle back and forth in a steady motion.
- Dispensing: Place the nozzle or hose end into the receiving container before you start pumping.
- Safety: Ensure the tank is properly vented and that you are using the pump only with compatible fluids (typically gasoline, diesel, or kerosene).
Note: Always ensure the pump is grounded if required by local fire codes when transferring flammable liquids. If you encounter resistance or leaks, stop immediately and check the seals.