Answer

Aug 29, 2025 - 10:00 PM
To reset the Sensata Technologies THK5 Absolute Rotary Encoder to its factory settings, you can use the System-Command feature as outlined in the instruction manual. Here are the steps to perform a factory reset:
1. Refer to the System-Command section in the manual.
2. Locate Index 2 (0x02) and Subindex 0 for System-Command.
3. Set the Data type to UIntegerT 8.
4. Access should be Write Only (WO).
5. The Value range for a factory reset is 130 (0x82) for restoring factory settings.
By setting the System-Command to 130 (0x82), you will initiate the process to restore the Sensata Technologies THK5 Absolute Rotary Encoder to its original factory settings. This action will reset all parameters and configurations to their default values as specified in the factory settings parameters section of the manual.