Pyronix-LOGO

Pyronix XDL12TT-AM Security and Alarm System

Pyronix-XDL12TT-AM-Security-and-Alarm-System-PRODUCT

Product Information

Specifications:

  • Model: XDL12TT-AM
  • Includes: XD-FIXEDBRACKET, XD-WALLBRACKET, XD-45D-ADAPTER
  • Contact: +44(0)333 444 1280 (UK)
  • Email: customer.support@pyronix.com (UK)
  • Website: www.pyronix.com
  • Address: Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK

Product Usage Instructions

Mounting the Bracket
Depending on your installation requirements, choose between XD-FIXEDBRACKET and XD-WALLBRACKET. Use appropriate tools to securely mount the bracket at the desired location.

Attaching the Adapter (if applicable)
If using the XD-45D-ADAPTER, ensure it is securely attached to either the XD-FIXEDBRACKET or XD-WALLBRACKET as needed for your setup.

Contact Information
If you have any questions or issues with the product, please contact Pyronix Limited using the provided phone number or email address.

Environmental Class (EC) IV
9.9GHz: AT, BE, CH, CY, CZ, DK, EE, FI,FR, GR, HR, HU, IE, IS, IT, LT, MT, NL,PL, PT, SI, TR, UAE
10.525GHz: BE, CH, CY, DK, ES, HU, IE,IS, IT, MT, MY, NL, NO, SE, SI, UAE, USA
10.587GHz: GB, MY

Installation

Scan the QR code for fixing instructions and adapter information. Ensure that the detector is installed away from reflected sunlight and large objects.

Switches

Pyronix-XDL12TT-AM-Security-and-Alarm-System-FIG- (8)

If you disable the detector’s LEDs, you can remotely enable them in walk tests. Connect the detector’s LED terminal to a control panel PGM output that switches to 0V to enable the LEDs.

Microwave range and angle of detection
Use the highlighted dials to change the microwave range and angle of detection.

LEDs
Four LEDs show the status of the detector.

Lens inserts
Use lens inserts to control coverage.

Header pins
Place two-pin jumpers onto header pins to adjust resistance for alarm, masking/fault and tamper.

Anti-masking
Anti-masking triggers an alarm when part or all of the sensor is masked by an intruder. Use the highlighted dial to change the masking area range. When an intruder enters the masking area,LED2 pulses. When the intruder moves out of the masking area, if the detector does not see activation on all 3 sensors within 1 min, the mask/fault relay opens and LED1 and LED3 turn on.
To reset, remove the obstruction and perform a walk test for 1 min.

Blocking
Blocking detects intruders behind objects when the panel is disarmed. To use blocking, move switches 3 and 4 down, and connect the R1 input to a panel output that is negative when disarmed. When blocking is active, the alarm relay opens and LED1 and LED3 turn on. To reset, perform a walk test.

Connecting to CCTV and lights
To connect the detector to CCTV and lights, refer to the wiring diagram.

SPECIFICATION

  • Tri-detection method
    2 digital dual-element passive IR & 1 microwave doppler unit
  • Sensitivity
    AUTO or HIGH
  • Temperature compensation
    Digital
  • Pet immunity
    Up to 24kg, 1m high
  • Detection speed
    0.25 – 2.5m/s
  • Tri-masking
    Adjustable from 0m to 1m, covers all 3 technologies
  • Casing
    3mm polycarbonate, 0.4mm HDPE in Lens Area.
    IP Rating: IP55
  • Lenses
    UV compensated
    Operating voltage & current
    9 – 16V DC, (24mA @ 13.8V DC quiescent)
  • Relay output
    3 x SELV limits, 60V DC 50mA (42.4V AC peak)
  • Mounting height & range
    1m – 1.5m = 12m range
  • Tamper switches
    12V DC 50mA both front and rear
  • Temperature
    • Storage: -40°C to 80°C
    • Operating: -30°C to 70°C
  • Dimensions & weight
    188 x 77 x 84mm, 0.3kg

Product information

Applies to electrical products sold within the European community. At the end of the electrical product’s life,do not dispose of it with household waste. Where possible, recycle the product. Check with your Local Authority or retailer for recycling advice in your country.

Pyronix-XDL12TT-AM-Security-and-Alarm-System-FIG- (1)

Pyronix-XDL12TT-AM-Security-and-Alarm-System-FIG- (2) Pyronix-XDL12TT-AM-Security-and-Alarm-System-FIG- (3)

Pyronix-XDL12TT-AM-Security-and-Alarm-System-FIG- (5)

Pyronix-XDL12TT-AM-Security-and-Alarm-System-FIG- (4)

Pyronix-XDL12TT-AM-Security-and-Alarm-System-FIG- (6)

Warranty

This product is sold subject to our standard warranty conditions and is warranted again defects in workmanship for a period of five years (excluding lens). In the interest of continuing care and design, Pyronix Ltd reserves the right to amend specifications without giving prior notice.

The following languages are available online via the QR code: Bulgarian, Czech, Danish, German, Greek, Spanish, Finnish, French, Croatian, Hungarian, Italian, Dutch, Norwegian, Polish, Portuguese, Romanian, Russian, Slovak, Slovenian, Serbian, Swedish

Pyronix-XDL12TT-AM-Security-and-Alarm-System-FIG- (7)

+44(0)333 444 1280 (UK)

customer.support@pyronix.com (UK)

www.pyronix.com Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK

Frequently Asked Questions

Q: Can I use XD-FIXEDBRACKET and XD-WALLBRACKET together?
A: Yes, you can use them together along with the XD-45D-ADAPTER for a customized setup.

Q: Where can I find more information about Pyronix products?
A: Visit the Pyronix website at www.pyronix.com for detailed product information and resources.