Sartorius BCE 2202-1S

Sartorius Entris II Compact Precision Scale Lab Balance

Model: BCE 2202-1S User Manual

1. پیژندنه

This manual provides essential instructions for the proper setup, operation, and maintenance of your Sartorius Entris II Compact Precision Scale Lab Balance, model BCE 2202-1S. This high-precision weighing system is designed for laboratory applications, featuring a high-resolution color touchscreen display, RS-232, and USB interfaces, and requiring external calibration for accurate measurements.

Please read this manual thoroughly before using the device to ensure safe and correct operation and to achieve optimal performance.

2. د خوندیتوب لارښوونې

  • Always operate the balance on a stable, level surface free from vibrations.
  • Ensure the power supply matches the specifications indicated on the device.
  • Avoid exposing the balance to extreme temperatures, direct sunlight, or strong air currents.
  • Do not disassemble the balance; refer servicing to qualified personnel.
  • Keep the weighing pan and surrounding area clean and free from debris.
  • Use only original Sartorius accessories and spare parts.

3. محصول ختم شوview

The Sartorius Entris II BCE 2202-1S is a compact laboratory balance designed for precise measurements. Key components include the weighing pan, a high-resolution color touchscreen display, and intuitive control buttons.

Sartorius Entris II Compact Precision Scale Lab Balance

شکل 1: مخکی view of the Sartorius Entris II Compact Precision Scale Lab Balance. This image displays the balance with its stainless steel weighing pan, the digital display showing '0.00 g', and control buttons below the display, including power and tare functions. The Sartorius logo is visible on the front panel.

Sartorius Entris II Compact Precision Scale Lab Balance with dimensions

شکل 2: اړخ view of the Sartorius Entris II Compact Precision Scale Lab Balance with indicated dimensions. The image shows the balance from an angled perspective, highlighting its compact form factor. Dimensions are marked as approximately 8.66 inches in width, 7.56 inches in depth, and 2.13 inches in height.

4. ترتیب کول

  1. بسته بندي کول: Carefully remove the balance and all accessories from the packaging. Retain the original packaging for future transport or storage.
  2. ځای په ځای کول: Place the balance on a firm, level, and vibration-free surface. Ensure it is away from direct heat sources, air conditioning vents, and open windows to prevent measurement inaccuracies caused by temperature fluctuations or drafts.
  3. کچه کول: Use the adjustable feet at the base of the balance to level the device. Adjust until the air bubble in the spirit level (usually located near the display) is centered.
  4. د بریښنا پیوستون: Connect the provided power adapter to the balance and then to a suitable power outlet.
  5. ابتدايي اندازه کول: This model requires external calibration. Refer to Section 5.4 for detailed calibration procedures before first use to ensure accurate measurements.

5. عملیاتي لارښوونې

۸ پاور آن/بند

فشار ورکړئ ځواک button (usually marked with a circle and a vertical line) to turn the balance on or off. Allow a brief warm-up period for stable readings after powering on.

۶.۱ اساسي وزن کول

  1. Ensure the weighing pan is empty and the display shows '0.00 g'. If not, press the صفر تڼۍ
  2. هغه توکي چې وزن کېږي په احتیاط سره د وزن کولو لوښي په مرکز کې کیږدئ.
  3. Wait for the reading to stabilize (a stability indicator, often a small circle or arrow, will appear on the display).
  4. په سکرین کې ښودل شوي وزن ولولئ.

5.3 ټرینګ

Taring allows you to subtract the weight of a container, so only the net weight of the sample اندازه کیږي.

  1. Place the empty container onto the weighing pan.
  2. فشار ورکړئ توره button (usually marked with a 'T' or '→0←'). The display will reset to '0.00 g'.
  3. s اضافه کړئample to the container. The display will show the net weight of the sample.

5.4 External Calibration

External calibration ensures the accuracy of your balance. This procedure requires a certified calibration weight appropriate for the balance's capacity (e.g., 2000g for a 2220g balance).

  1. Ensure the balance is leveled and has been warmed up for at least 30 minutes.
  2. Access the calibration menu via the touchscreen display. (Consult the on-screen prompts or the full Sartorius user manual for specific menu navigation).
  3. Follow the on-screen instructions to initiate the external calibration process.
  4. When prompted, place the specified calibration weight onto the center of the weighing pan.
  5. Wait for the balance to complete the calibration process.
  6. Remove the calibration weight when instructed. The balance will return to normal weighing mode.

6. ساتنه

6.1 پاکول

  • Disconnect the balance from the power supply before cleaning.
  • Clean the weighing pan and housing with a soft, damp ټوکر او یو نرم صابون.
  • Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the display or housing.
  • Ensure no liquids enter the balance housing.

6.2 پاملرنه

  • Handle the balance with care; avoid dropping or subjecting it to shocks.
  • Regularly check the leveling of the balance.
  • Perform periodic external calibrations to maintain accuracy.

7. ستونزه حل کول

  • بې ثباته لوستل: Check for drafts, vibrations, or temperature fluctuations. Ensure the balance is level.
  • Display Error Message: Refer to the full Sartorius user manual for specific error codes. Often, a power cycle (turning off and on) can resolve minor issues.
  • Balance Not Powering On: Check the power cable connection and the power outlet. Ensure the power adapter is functioning correctly.
  • ناسم لوستل: Perform an external calibration (refer to Section 5.4). Ensure the weighing pan is clean and correctly seated.

If problems persist, contact Sartorius customer support or an authorized service technician.

8. مشخصات

فیچرمشخصات
ماډلBCE 2202-1S
برانډسارټوریوس
اعظمي ظرفیت2220 ګرامه
Readability (Resolution)0.01 ګرامه
د ښودلو ډولHigh-resolution color touchscreen
د کیلیبریشن ډولبهرنی
انٹرفیسونهRS-232، USB
د توکي وزن14 پونډه
نیټه لومړی شتون لريد ۲۰۲۳ کال د نومبر ۳۰مه

9. تضمین او ملاتړ

For warranty information, technical support, or service inquiries, please refer to the official Sartorius website or contact your authorized Sartorius dealer. Keep your purchase receipt and product serial number readily available when contacting support.

اړوند اسناد - BCE 2202-1S

مخکېview سارتوریس سي پي | د جیمپلس لړۍ الکترونیکي بیلانسونه - د کارونې لارښوونې
د سارتوریس CP لپاره جامع عملیاتي لارښوونې | د جیمپلس لړۍ بریښنایی مایکرو، تحلیلي، او دقیق توازن، په شمول د CPA، GCA، او GPA ماډلونو. نصب، عملیات، ترتیب، د غوښتنلیک پروګرامونه، د ستونزو حل کول، ساتنه، او مشخصات پوښي.
مخکېview د سارتوریس پورټ ایبل او سرو زرو لړۍ خدماتو لارښود: د ساتنې او ترمیم لارښود
د سارتوریس پورټ ایبل او سرو زرو لړۍ وزن کولو پیمانو (PT...-000V1 او GT...-G00V1) لپاره جامع خدمت لارښود. د خدماتو تخنیکرانو لپاره تنظیم، کیلیبریشن، ترمیم پروسیجرونه، ستونزې حل کول، او د معلوماتو انٹرفیس معلومات پوښي.
مخکېview سارتوریس سیکورا، کوینټیکس، پراکتم لابراتوار بیلانس کارن لارښود
د سارتوریس سیکورا، کوینټیکس، او پراکتم لابراتوار توازن لپاره جامع کارونکي لارښود. د نصبولو، عملیاتو، خوندیتوب لارښوونو، د وزن کولو مختلف غوښتنلیکونو، د سیسټم ترتیباتو، او دقیق لابراتوار اندازه کولو لپاره تخنیکي مشخصاتو توضیحات.
مخکېview Manuale d'uso Sartorius CP Gemplus: Istruzioni per Bilance Analitiche e di Precisione
Guida completa alle istruzioni per l'uso delle bilance elettroniche Sartorius CP e Gemplus (modelli CPA, GCA, GPA). Copre installazione, funzionamento, impostazioni, manutenzione e specifiche tecniche.
مخکېview د سارتوریس لابراتوار بیلانس کراس ریفرنس لارښود: خپل مناسب ماډل ومومئ
د کیوبیس MSE، سیکورا، کوینټیکس، پراکتم، او انټریس لړۍ کې د سارټوریوس لابراتوار توازن ماډلونه پرتله کړئ. د خپل لابراتوار وزن کولو اړتیاو لپاره د بدیل ماډلونه او د FS کتلاګ شمیرې ومومئ.
مخکېview سارتوریس سیکورا، کوینټیکس، پراکتم لابراتوار بیلانس کارن لارښود
This user manual provides comprehensive instructions for Sartorius Secura®, Quintix®, and Practum® laboratory balances. It details installation, operation, calibration, maintenance, and various weighing applications, ensuring optimal performance and accuracy for laboratory professionals.