Practical Method for Assessing Cover Readings

  • The German Concrete and Construction Association (Deutscher Beton- und Bautechnik-Verein,DBV) have published a practical guideline for assessing concrete cover on real structures.
  • The minimum concrete cover cmin is to be substantiated as:
    • 10%-quantile for elements according to DIN 1045-1, table 4 row 1 [R1] (XC1)
    • 5%-quantile for elements according to DIN 1045-1, table 4, rows 2-4 [R1]. (XC2-XC4)

Measurement Surfaces

The following concrete structure surfaces are to be differentiated as measurement surfaces:

  • each side of a wall
  • the upper side of a ceiling
  • the under side of a ceiling
  • the sides of rectangular pillars
  • the vertical sides of a beam
  • the under side of a beam
  • the upper side of a beam

Each measurement surface equates to a basic population.
As a minimum 20 measurements are required for each surface.

  • The German Concrete and Construction Association ( D eutscher B eton und Bautechnik V erein, DBV) have published a practical guideline for assessing concrete cover on real structures.
  • The minimum concrete cover c min is to be substantiated as:
    • 10 quantile for elements according to DIN 1045 1 , table 4 row 1 [R 1 ] (XC 1
    • 5 quantile for elements according to DIN 1045 1 , table 4 , rows 2 4 [R 1 ]. (XC 2 XC 4

DBV Evaluation Requirements

  • The Neville distribution is the basis for the statistical evaluation.
  • It’s usability has been proven by carrying out parameter studies on finished structural elements.
  • Each measurement surface (see previous slide) equates to a basic population.
  • As a minimum 20 measurements are required for each surface.
  • For the quantitative evaluation, after acquiring all of the measurement values, the first step is to determine the median X M.
  • Following this, in order to increase the validity, an upper boundary value X OG is calculated from the median X M and the smallest measured value X min to be used for the evaluation of the measured values X i
  • Measurement values that exceed this upper boundary value, are to be excluded and the quantitative analysis will be carried out with the reduced measurement series.

DBV Evaluation Procedure

proceq Profometer PM8000 Pro-2

DBV statistics feature

  • Relevant statistics without further processing
  • for efficient and informed decision making

proceq Profometer PM8000 Pro-1

Better decisions with advanced statistics

Documents / Resources

PDF thumbnailProfometer PM8000 Pro
User Guide · Profometer PM8000 Pro, Profometer, Profometer PM8000, PM8000, PM8000 Pro

References

Questions and answers

Helpful product questions tied to this manual. Each item links to the full Q&A page.

Browse all questions about this manual

Questions & Answers

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

  1. comment cree un compte

    Morched Tounsi asks comment cree un compte
    Manuals+ clarified question
    Question

    How do I create an account?

    Answer

    To use the Profometer PM8000 Pro with its advanced statistics features, you need to use the Profometer App (available on the Apple App Store). While the provided manual focuses on the DBV guideline evaluation procedures, Proceq products typically require a Screening Eagle ID to access cloud features and app functionality.

    To create an account:

    • Download and open the Profometer App on your iPad.
    • Select the option to Sign Up or create a new Screening Eagle ID.
    • Follow the on-screen prompts to enter your email address and verify your account.

    If you are looking to create a local project or measurement series rather than a user account, you can do this directly within the app's measurement interface.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.