PowerWalker Basic VI STL Series Interface Device User Manual

PowerWalker-LOGO

PowerWalker Basic VI STL Series Interface Device

PowerWalker Basic VI STL Series Interface Device-PRODCUT

IMPORTANT SAFETY INSTRUCTIONS

(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.

  • CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity-controlled indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and humidity range.)
  • CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS’s cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat-emitting appliances such as space heaters or furnaces.
  • CAUTION! Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners, to UPS.
  • CAUTION! Do not plug the UPS input into its own output.
  • CAUTION! Do not allow liquids or any foreign objects to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit.
  • CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS.
  • CAUTION! Do not attach a power strip or surge suppressor to the UPS.
  • CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
  • CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
  • CAUTION! The battery supply should therefore be disconnected at the plus and minus poles at the quick connectors of the battery when maintenance or service work inside the UPS is necessary.
  • CAUTION! Internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery.
  • CAUTION! When replacing the batteries, use the same number and type of batteries.
  • CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released electrolytes are harmful to the skin and eyes.

INSTALLING YOUR UPS SYSTEM

UNPACKING
The box should contain the following:

  1. UPS Unit x1;
  2. User Manual x 1;

OVERVIEW
The UPS provides automatic voltage regulation for inconsistent utility power, provides battery backup during power outages, and ensures consistent power to your computer system.

HARDWARE INSTALLATION GUIDE

  1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours isrecommended to ensure that the battery’s maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will charge in both the on and off position.
  2. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage device (Zip drive, Jazz drive, Tape drive), etc., into the battery power supplied outlets. DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder, or other large electrical device into the battery power supplied outlets. The power demands of these devices will overload and possibly damage the unit.
  3. Plug the UPS into a 2-pole, 3-wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g., air conditioner, refrigerator, copier, etc. Avoid using extension cords.
  4. Press the power switch to turn the unit on. The power on indicator light will illuminate, and the unit will “beep”.
  5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Wait 10 seconds. Make sure the circuit breaker/fuse is normal, and then turn the UPS on.
  6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
  7. To store your UPS for an extended period, cover it and store it with the battery fully charged. Recharge the battery every three months to ensure battery life.

BASIC OPERATION

Front panel

  1. LCD Display
    The LCD will display the UPS status, including input voltage, output voltage, percentage of load, and battery…etc.
  2. Power Switch
    Press the switch for 2 seconds to turn the UPS ON or OFF.
  3. Led Indicators
    LCD dimming setting: the auto-dimming function can be turned OFF/ON by pressing the button for 10s. The default setting is LCD dimming function off.

PowerWalker Basic VI STL Series Interface Device-FIG- (1)

Rear panel

  1. USB COMM. Port
    This port allows connection and communication from the USB port on the computer to the UPS unit.
  2. RJ45/11 Communication Protection Ports
    Communication protection ports will protect any standard modem, fax, telephone line, or network cable.e
  3. Input Circuit Breaker
    The circuit breaker provides optimal overload protection.
  4. Input power cord
    Connect to utility power.
  5. Battery Backup & Surge-Protected Outlets
    Provide battery backup and surge protection. They ensure power is provided to connected equipment over a period of time during a power failure.

PowerWalker Basic VI STL Series Interface Device-FIG- (5)

TECHNICAL SPECIFICATIONS

Model VI 600 STL VI 800 STL VI 1000 STL VI 1200 STL VI 1500 STL VI 2200 STL
Capacity(VA/W) 600/360 800/480 1000/600 1200/720 1500/900 2200/1320
Input
Voltage Range 162~290Vac
Nominal Frequency 50/60Hz
Output
On Battery Output Voltage Simulated Sine Wave at 230Vac +/-10%
On Battery Output Frequency 50/60Hz +/-1%
Overload Protection Breaker / Fuse
Physical
Dimensions (W x H x D)(mm) 96 x 138 x 286 148 X 178 X 298
Battery
Sealed Maintenance Free Lead Acid Battery 12V 7AH x1 12V 7.2AH

x1

12V 9AH x1 12V 7AH x2 12V 7.2AH

x2

12V 9AH x2
Typical Recharge Time 8 Hours
Warning Diagnostics
Indicators Power On
Audible Alarms On Battery, Low Battery, Overload, Fault
Environmental
Operating Temperature 0℃ to 40℃
Operating Relative Humidity 0 to 90%
Management
Auto-Charger Yes
Auto-Restart Yes
USB COMM. Port Yes, with HID support
RJ45/11 Communication

Protection Ports

Yes, surge protection

DEFINITIONS FOR ILLUMINATED LCD INDICATORS

LCD Indication

PowerWalker Basic VI STL Series Interface Device-FIG- (2)

PowerWalker Basic VI STL Series Interface Device-FIG- (3)

Line mode & Batt. Mode

PowerWalker Basic VI STL Series Interface Device-FIG- (4)

TROUBLE SHOOTING

Problem Possible Cause Solution
The UPS does not perform as expected

runtime

Batteries are not fully charged. Recharge the battery by leaving the UPS plugged in.
The battery is slightly worn out. Contact Technical Support.
 

 

The UPS will not turn on.

The on/off switch is designed to prevent damage by rapidly turning it off and on. Turn the UPS off. Wait 10 seconds and then turn the UPS on.
The unit is not connected to an AC outlet. The unit must be connected to a 230VAC 50/60Hz

outlet.

The battery is worn out. Contact Technical Support.
Mechanical problem. Contact Technical Support.
 

 

Outlets do not provide power to equipment.

 

The circuit breaker is tripped due to overload

Turn the UPS off and unplug at least one piece

connected equipment. Unplug the power cord of the UPS, then press the circuit breaker knob.

Batteries are discharged Allow the unit to recharge for at least 4 hours.
The unit has been damaged by a surge or spike. Contact Technical Support.
 

Fault code F09

 

Output Short: Output circuit short.

Shut down the UPS. Your attached equipment may have problems. Please remove them and check

again.

Fault code F12 Battery voltage is too low. Shut down your computer and recharge the battery immediately.
Fault code F13 The battery is overcharged. Contact Technical Support.
 

Fault code F14

Overload occurs:

Your equipment requires more power than the UPS can provide. It will shut down.

Shut off non-essential equipment. If this solves the overload problem, the UPS will transfer to normal

operation.

SOFTWARE DOWNLOAD

PowerMaster+ management software provides a user-friendly interface for your power systems. The graphic user interface is intuitive and displays essential power information at a glance. Please follow the procedure below to install the software.

Installation procedure

  1. Download PowerMaster+ from the website: http://powermaster.powerwalker.com/
  2. Double-click the file and follow the installation steps.
    When your computer restarts, the Power Master+ software will appear as a blue icon located in the system tray.

FAQS

How often should I recharge the UPS battery?

It is recommended to recharge the battery every three months to ensure battery life.

Documents / Resources

PDF thumbnailBasic VI STL Series Interface Device
User Manual · 600, 800, 1000, 1200, 1500, 2200, Basic VI STL Series Interface Device, Basic VI STL Series, Interface Device, Device