Product Information

The PowerStream PST-UPS4 is a DC/DC UPS Controller designed to provide standby power to a device operating on a nominal 12 volt DC power. It has a current capacity of 5 Amps.

Product Usage Instructions

To connect the power supply and the device to be powered, followthese steps:

  1. Identify the 6 terminals for power connections.
  2. Ensure that the power terminals are connected using AWG18wires.
  3. Connect the positive connection from the Primary (Main) power supply to the red wire.
  4. Connect the negative connection from the Primary (Main) power supply to the black wire.
  5. Connect the positive connection to the device to be powered (Output) to the yellow wire.
  6. Connect the negative connection to the device to be powered (Output) to the black wire.
  7. The grey, green, and orange wires are used for optional voltage measurement of the two batteries.
  8. Ensure that the gauge of the wires used for connections is18AWG for power terminals and 22AWG for voltage dividerterminals.

Refer to the designator table below for better understanding:

Designator Main input Main ground Load Battery positive Battery negative Voltage divider ground Voltage divider main battery voltage Voltage divider auxiliary battery voltage
Color Red Black Yellow White Blue Grey Green Orange
Gauge 18AWG 18AWG 18AWG 18AWG 18AWG 22AWG 22AWG 22AWG

Make sure to follow the instructions carefully for proper installation and usage of the PowerStream PST-UPS4 DC/DC UPS Controller.

The PST-UPS4 is used to provide standby power to a device operating on a nominal 12 volt DC power. The
current capacity of the PST-UPS4 is 5 Amps.

Connections

There are 6 terminals for the power connections.

Power Connections

  • The connection for the power terminals are AWG18 wires
  • The positive connection from the Primary (Main) power supply should be connected to the red wire.
  • The negative connection from the Primary (Main) power supply should be connected to the black wire .
  • The positive connection to the device to be powered (Output) should be connected to the yellow wire.
  • The negative wire to the device to be powered (Output) should be connected to the black wire
  • The grey, green and orange wires are a voltage divider that allows optional measurement of the voltages of the two batteries..
Designator Color Gauge
Main input Red 18AWG
Main ground Black 18AWG
Load Yellow 18AWG
Battery positive White 18AWG
Battery negative Blue 18AWG
Voltage divider ground Grey 22AWG
Voltage divider main battery voltage Green 22 AWG
Voltage divider auxiliary battery voltage Orange 22AWG