POWER LAB RPL00 Power Fuse Switch
Specifications
- Product Name: Power LAB RPL00 Fuse Enclosures
- Applications: AC & DC
- Fire Resistance Class: V0
- Quick Installation with Compact Design
- Safety Features Included
- Flexible Adjustment for Various Needs
- Cost Savings in Operations
Product Usage Instructions
Installation:
- Ensure the power source is disconnected before installation.
- Mount the RPL00 fuse enclosures securely in the designated location.
- Connect the appropriate cables to the insert size specified for your application.
Adjustment:
- Use the flexible adjustment features to customize the settings according to your requirements.
- Follow the provided guidelines for safe and efficient adjustment.
Maintenance:
- Regularly inspect the fuse enclosures for any signs of damage or wear.
- Replace fuses as needed to ensure optimal performance.
RPL00 fuse enclosures
- AC&DC applications
- V0 fire resistance class
- Quick installation
- Compact design
RPL00
Insert size | NH00 | |
Rated voltage Ue [V] | AC380 | AC660 |
Rated current Ie [A] | 160 | 100 |
Rated thermal current Ith [A] | 160 | 100 |
Rated short-time withstand current [kA] | 100 | 50 |
Rated insulation voltage Ui [V] | 800 | |
Rated impulse withstand voltage Uimp [kV] | 8 | |
AC-23B | ||
Service category | AC-22B
AC-21B |
|
AC-20B | ||
Electrical life [cycles] | 200 |
Dimensions [mm]
Safety Guidelines
- Proper Fuse Selection & Installation
- Use only the correct type and rating of fuse for both AC and DC circuits. An appropriately rated fuse ensures reliable over-current protection and helps prevent fires or equipment damage.
- Ensure Fire Resistance
- The RPL00 is built with V0 flame-retardant materials, meaning it is designed to resist ignition and minimize fire risk—make sure the device remains intact and undamaged.
- De-Energize Before Handling
- Always disconnect power before installing, adjusting, or servicing the fuse switch to avoid shock hazards and ensure you’re safe during handling.
- Observe Load Limits
- Understand and respect the switch’s voltage, current, and power limits. Exceeding these thresholds can cause overheating, fuse degradation, or catastrophic failure.
- Proper Mounting & Ventilation
- Install the switch in a secure, stable location away from moisture and combustible materials. Ensure adequate ventilation to prevent heat build-up and monitor for signs of wear or loose connections.
- Regular Inspection and Testing
- Periodically check for signs of damage—such as cracks, discoloration, or heating—and test the electrical circuit with appropriate safety tools. Replace fuses or components as needed.
- Professional Intervention for Faults
If you notice any irregular behavior like frequent fuse blowing or electrical arcing, seek help from a qualified technician rather than attempting DIY fixes, especially if the root cause is unclear.
Contact
- Contact: tel. +48 663 16 16 16, e-mail: office@powerlab.com.pl, powerlab.com.pl
FAQs
Q: What are the rated voltage and current specifications for the RPL00 fuse enclosures?
A: The rated voltage is AC380V and AC660V, with rated currents of 160A and 100A, respectively.
Q: Are the fuse enclosures suitable for both AC and DC applications?
A: Yes, the RPL00 fuse enclosures are designed for use in both AC and DC applications.