Specifications

  • Mounting Type: Inside, Outside, Ceiling, Wall
  • Number of Channels: 2, 3, 4, 5
  • Mounting Depth Requirements:
    • IM Flush Mount Depth: 2-1/2, 2-3/4, 3-1/2, 3-1/2
    • IM with Valance Flush Mount Depth: 3-1/2, 3-3/4, 4-1/2, 4-1/2
    • IM Minimum Depth: 1-3/4, 1-3/4, 1-3/4, 2
  • OM Overall Projection: Varies based on installation

Product Usage Instructions

Inside or Ceiling Mount:

  1. Mark the bracket location. Measure 4 from the edge of the window frame (or edge of the track for the ceiling) on each side and mark the location. Space the additional installation brackets evenly between the 2 end brackets and mark the location(s).
  2. Mount the brackets. Place the bracket(s) against the top of the window frame (or ceiling) and attach using the provided screw(s).
  3. Attach the track. Position track in place where it is centered in the window and the operating wand is on the correct side. Hook front of track onto the lip of the bracket and snap back of track into back of bracket.

Outside and Wall Mount:
Mounting the Panels: Unpack each panel and align the Velcro strip on the fabric to the one on the carrier. Press the fabric against it until the panel is secured. Repeat for all panels.

Mount the Fabric Cornice – Inside Mount:

  1. Center the cornice in desired location.
  2. Mark the mounting surface 2 from each jamb for screw location. Center the marks in the bracket slots. Space screws evenly, but no more than 24 apart.
  3. Drill screw holes. Use drywall anchors when mounting into drywall.
  4. Install the cornice through the slotted angle bracket to the mounting surface with the #8 x 1-1/4 screws provided.

Getting Started — Mounting Type

All of the required installation components are wrapped in the package along with these instructions. Please thoroughly review these instructions before beginning the installation. Some parts may vary depending upon your selected mounting options or control system options.

  • 2 and 3 Way Inside/Outside Mount Installation Bracket
  • 4 and 4 Way Inside/Outside Mount Installation Bracket
  • L Bracket Outside/Wall Mount
  • Track Splice Bracket (for tracks over 144” wide)
  • Installation Bracket (Outside Mount Only) Slotted Angle Bracket
  • Outside/Wall Mount Bracket Assembly

If the installation brackets are mounted correctly, the rest of the installation process will follow easily.

Prior to mounting the brackets, add any clearance depth required to avoid obstructions:

Mounting Depth Requirements
Number of Track Channels IM

Flush Mount Depth

IM with Valance Flush Mount Depth IM

Minimum Depth

OM

Wall Clearance

OM

Overall Projection

2 2-1/2” 3-1/2” 1-3/4” 2-1/2” – 3-1/8” 4-1/8” – 4-3/4”
3 2-3/4” 3-3/4” 1-3/4” 2-1/2” – 3-1/8” 4-1/2” – 5-1/4”
4 3-1/2” 4-1/2” 1-3/4” 2-1/2” – 3-1/8” 5-1/4” – 6”
5 3-1/2” 4-1/2” 2” 1-3/4” – 4” 5-1/8” – 7-3/8”

Fasteners

  • #8 screws for wood or aluminum
  • Plastic inserts for drywall or plaster
  • Auger threaded metal or plastic inserts for drywall
  • Molly bolts for drywall
  • Toggle bolts fordrywall or lath & plaster

Porter-Preston-Roller-Shade-Panel-Track-FIG- (3)

IMPORTANT: For installation in wood or aluminum frames, it is recommended you use the sheet metal screws included with your custom shades. For other types of wall or window construction you will need to furnish different fasteners.

Note: Fastener strength should be rated more than the weight of the shade.

Panel Track hardware installation brackets are either 2 and 3 or 4 and 5 way. Mounting the brackets level is essential to proper operation.

Mounting

Inside or Ceiling Mount

Porter-Preston-Roller-Shade-Panel-Track-FIG- (4)

  1. Mark the bracket location. Measure 4” from the edge of the window frame (or edge of the track for the ceiling) on each side and mark the location. Spacethe additional installation brackets evenly between the 2 end brackets and mark the location(s). Make sure that the brackets are level with each other.Verify adequate clearance allowance is made for panel operation.
  2. Mount the brackets. Place the bracket(s) against the top of the window frame (orceiling) and attach using the provided screw(s).
  3. Attach the track. Position track in place where it is centered in the window and the operating wandis on the correct side. Hook front of track onto the lip of the bracket and snap back of track into back of bracket.

Outside and Wall Mount

Porter-Preston-Roller-Shade-Panel-Track-FIG- (5)

  1. Mark the bracket location. Measure 4” from the edge of the window frame (or edge of the track for ceiling) on each side and mark the location. Space the additional installation brackets evenly between the 2 end brackets and mark the location(s). Make sure that the brackets are level with each other. Verify adequate clearance allowance is made for panel operation.
  2. Mount the brackets. Place the wall-mount bracket(s) assembly against the top of the window frame and attach using the provided screw(s).
  3. Attach the track. Position track in place where it is centered in the window and the operating wand is on the correct side. Hook front of track onto the lip of the bracket and snap back of track into back of bracket.

Mounting the Panels

Porter-Preston-Roller-Shade-Panel-Track-FIG- (6)

First, unpack each panel and align the Velcro strip on the fabric to the one on the carrier. Then, starting from one end, start pressing the fabric against it until the panel is secured. Repeat this process until all panels are in place.

Mount the Fabric Cornice

INSIDE MOUNT

Porter-Preston-Roller-Shade-Panel-Track-FIG- (7)

  1. Center the cornice in desired location.
  2. Mark the mounting surface 2” from each jamb for screw location. Center the marks in the bracket slots. Space screws evenly, but no more than 24” apart.
  3. Drill screw holes. IMPORTANT: Use drywall anchors when mounting into drywall.
  4. Install the cornice through the slotted angle bracket to the mounting surface with the #8 x 1-1/4” screws provided.

OUTSIDE MOUNT

Porter-Preston-Roller-Shade-Panel-Track-FIG- (8)

  1. Attach the returns to the valance. Check the angle on each return, fasten screws into the valance and repeat for opposite return.
  2. Skip to next step if ordered with a shade. If ordered custom returns under Fabric Cornice Only (without shade), place the 8” bracket on top of the slotted angle next to the return. With the back of the bracket flush with the back edge of the return, mark the cut mark just past the screw hole that lines up with the slotted angle. Then cut the bracket at the mark.
  3. Measure distance from top edge of cornice to the first complete hole in the slotted angle. Use that measurement to mark the location for the first bracket at the desired height. Repeat for the opposite bracket. Space brackets evenly, but no more than 24” apart.
  4. Drill screw holes. IMPORTANT: Use drywall anchors when mounting into drywall.
  5. Attach the installation brackets with the screws provided. Ensure the mounting surface is level and brackets are aligned. Shim brackets, if needed.
  6. Using the bolts and nuts provided, attach the slotted angle on top of the installation brackets.

Operate the Panel Track

Porter-Preston-Roller-Shade-Panel-Track-FIG- (9)

Tracks operate with a wand.

FAQ

Q: What type of fasteners should I use for wood or aluminum frames?
A: It is recommended to use the sheet metal screws included with your custom shades for wood or aluminum frames. For other types of wall or window construction, you will need to furnish different fasteners. Ensure that the fastener strength is rated more than the weight of the shade.

Q: How do I ensure proper operation of the Panel Track hardware installation brackets?
A: Mounting the brackets level is essential to proper operation. Make sure to follow the provided instructions for correct bracket placement and alignment.

Documents / Resources

Porter Preston Roller Shade Panel Track [pdf] Installation Guide
RS_PT_INSTALL_USA_C8-10-4453-1, Roller Shade Panel Track, Shade Panel Track, Panel Track

References

Leave a comment

Your email address will not be published. Required fields are marked *