Specifications:

  • Model: PAPI004174-M
  • Version: 20.11
  • Interface: Electronic Box
  • Functions: pH probe calibration, manual pH corrector injection, pH measurement adjustment, alarms

Product Usage Instructions

1. Interface

Visual representation:

1 : Command buttons

2 : Red indicator light

2. Calibration of pH Probe

  1. Remove the pH probe from the solution.
  2. Replace it with the provided cap.
  3. Press and hold the right button until a message blinks.
  4. Press the up or down button to navigate through menus until desired message blinks.
  5. Press the right button to validate the selection.
  6. Follow on-screen instructions without touching the probe during the process.
  7. To exit, press the left button.

3. Manual Injection of pH Corrector

  1. Follow steps 1 to 5 from the calibration process.
  2. Press the left button twice to initiate manual injection mode.
  3. Follow on-screen instructions for manual injection without touching the probe.

INSTALLATION DIAGRAMpooltech-PAPI004174-M-pH-Regulator-fig (1)

Warning

The pH corrector container must be installed a safe distance away from any electrical device or any other chemicals.

  1. Electronics box
  2. Ballast filter
  3. Peristaltic pump
  4. Pool Terre (optional)
  5. Probe holder
  6. Injection connector
  7. pH probe
  8. Bracket
  9. Semi-flexible tubing

ELEMENTS NOT SUPPLIED :

  1. Electrical power supply
  2. pH corrector container
  3. Copper cable
  4. Electrolysis cell
  5. Filter
  6. Ground rod
  7. Heat pump
  8. Filtration pump

ELECTRONICS BOX

Interface

Non-contractual visual : pooltech-PAPI004174-M-pH-Regulator-fig (2)

  1. Command keys
  2. Red LED If lit continuously : electronics box stopped. If flashing :pooltech-PAPI004174-M-pH-Regulator-fig (3) alarm triggered.
  3. Screen Default display : pH measurement.
  4. Green LED If lit continuously : electronics box in operation. If flashing : peristaltic pump running.

Switching on and off

Make a long press on the left key. When switching on, a chaser is displayed for a few seconds, then the pH measurement is displayed. The pH regulation is activated automatically.

Meaning of menus

pooltech-PAPI004174-M-pH-Regulator-fig (4)

Adjustment of the pH setpoint

  • Possible settings : from 6.8 to 7.6, in steps of 0.1.
  • Default setting : 7.2.
  1. Make a long press on the right key until the messagepooltech-PAPI004174-M-pH-Regulator-fig (5) flashes.
  2. Press the up or down key x times until the messagepooltech-PAPI004174-M-pH-Regulator-fig (6) flashes.
  3. Press the right key : the flashing value is the saved setpoint.
  4. Select a value with the up/down keys.
  5. Press the right key to validate : the selected value freezes briefly, then the message pooltech-PAPI004174-M-pH-Regulator-fig (6)flashes.
  6. Press the left key twice to return to the default display.

Calibration of the pH probe

The supplied pH probe is already calibrated. It is therefore not necessary to calibrate the pH probe when the equipment is put into service for the first time.

Warning

  • However, in order to ensure optimal pH regulation, it is imperative to calibrate the pH probe at the start of each season when putting back into service, and after each replacement of the probe.
  1. Switch off the filtration (and therefore the electronics box).
  2. Open the standard solutions pH 7 and pH 10 (use only single-use standard solutions).
  3.  If the probe is already installed :
    • Extract the probe from the probe holder, without disconnecting it.
    • Remove the nut from the probe holder and replace it with the plug provided.
    • If the probe is not yet installed : Connect the probe to the electronics box.
  4. Switch on the electronics box.
  5.  Make a long press on the right key until the messagepooltech-PAPI004174-M-pH-Regulator-fig (5) flashes.
  6.  Press the up or down key x times until the messagempooltech-PAPI004174-M-pH-Regulator-fig (8) flashes.
  7. Press the right key to validate : the message pooltech-PAPI004174-M-pH-Regulator-fig (9)flashes.
  8. Insert the probe into the pH 7 standard solution, then wait a few minutes.
  9. Press the right key : the display below appearspooltech-PAPI004174-M-pH-Regulator-fig (7)
    • Do not touch the probe during this time, and wait until you get one of the displays below.
  10. 2 Possibilities :
    • The message pooltech-PAPI004174-M-pH-Regulator-fig (31)flashes. In this case, go to step 11.
    • The messagepooltech-PAPI004174-M-pH-Regulator-fig (12) is displayed : calibration failed. To acknowledge this display, press the left key. In this case, visually check the condition of the probe, then attempt the calibration again, several times if necessary. If the calibration still fails, change the probe and recalibrate.
  11. Insert the probe into the pH 10 standard solution, then wait a few minutes.
  12.  Press the right key : the display below appears.pooltech-PAPI004174-M-pH-Regulator-fig (10)
    • Do not touch the probe during this time, and wait until you get one of the displays below.
  13. 2 Possibilities :
    1. The message pooltech-PAPI004174-M-pH-Regulator-fig (11)is displayed briefly, then the messagepooltech-PAPI004174-M-pH-Regulator-fig (8) flashes. Calibration is complete.
    2. The messagepooltech-PAPI004174-M-pH-Regulator-fig (12) is displayed : calibration failed. In this case, visually check the condition of the probe, then attempt the calibration again, several times if necessary. If the calibration still fails, change the probe and recalibrate.
    3. To acknowledge these displays, press the left key twice : the default display appears.

Warning

  • The pH 7 and pH 10 standard solutions are for single use. To avoid handling errors, discard these solutions after use.

Specification of the type of pH corrector used

  • Possible settings :pooltech-PAPI004174-M-pH-Regulator-fig (13) (acidic),pooltech-PAPI004174-M-pH-Regulator-fig (14) (basic).
  • Default setting : pooltech-PAPI004174-M-pH-Regulator-fig (13).
  1. Make a long press on the right key until the messagepooltech-PAPI004174-M-pH-Regulator-fig (5) flashes.
  2. Press the up or down key x times until the messagepooltech-PAPI004174-M-pH-Regulator-fig (15) flashes.
  3. Press the right key : the flashing message corresponds to the type of pH corrector recorded.
  4. Select a type of pH corrector with the up/down keys.
  5. Press the right key to validate : the type of pH corrector selected freezes briefly, then the messagepooltech-PAPI004174-M-pH-Regulator-fig (15) flashes.
  6. Press the left key twice to return to the default display.

Specification of the pH concentration rate used

  • Possible settings : from pooltech-PAPI004174-M-pH-Regulator-fig (16)topooltech-PAPI004174-M-pH-Regulator-fig (17) (i.e. from 5% to 55%, in steps of 1%).
  • Default setting :pooltech-PAPI004174-M-pH-Regulator-fig (18)
  1. Make a long press on the right key until the messagepooltech-PAPI004174-M-pH-Regulator-fig (5) flashes.
  2.  Press the up or down key x times until the message pooltech-PAPI004174-M-pH-Regulator-fig (19)flashes.
  3.  Press the right key : the flashing value is the pH concentration rate recorded.
  4.  Select a value with the up/down keys.
  5. Press the right key to validate : the selected value freezes briefly, then the messagepooltech-PAPI004174-M-pH-Regulator-fig (19) flashes.
  6.  Press the left key twice to return to the default display.

Manual injection of pH corrector

This function also allows you to prime the peristaltic pump.

  • Possible settings of the injection duration : pooltech-PAPI004174-M-pH-Regulator-fig (20)from topooltech-PAPI004174-M-pH-Regulator-fig (21) (i.e. from 1 s to 60 s, in steps of 1 s), then frompooltech-PAPI004174-M-pH-Regulator-fig (22) topooltech-PAPI004174-M-pH-Regulator-fig (23) (i.e. from 1 min 10 s to 9 min 50 s, in steps of 10 s).
  • Setting the default injection duration :pooltech-PAPI004174-M-pH-Regulator-fig (21) .
  • To set the injection duration and then start the injection :
    1. Make a long press on the right key until the messagepooltech-PAPI004174-M-pH-Regulator-fig (5) flashes.
    2. Press the right key : the default injection duration flashes (60 s).
    3. Select an injection duration with the up/down keys.
    4.  Press the right key to validate the duration and start the injection : the injection duration is displayed in real time (time countdown). To stop the injection before the time has elapsed, press the left or right key.
    5. When the injection is complete, press the left key twice to return to the default display.

Adjustment of the pH measurement

  • Possible settings : from 6.5 to 7.5, in steps of 0.1.
    1.  Make a long press on the right key until the message pooltech-PAPI004174-M-pH-Regulator-fig (5)flashes.
    2.  Press the up or down key x times until the messagepooltech-PAPI004174-M-pH-Regulator-fig (24) flashes.
    3.  Press the right key.
    4.  Select a value with the up/down keys.
    5. Press the right key to validate.
    6. 2 Possibilities :
      • The messagepooltech-PAPI004174-M-pH-Regulator-fig (25) is displayed briefly, then the message pooltech-PAPI004174-M-pH-Regulator-fig (24)flashes : the adjustment is complete.
      • The message pooltech-PAPI004174-M-pH-Regulator-fig (26)is displayed briefly, then the messagepooltech-PAPI004174-M-pH-Regulator-fig (24) flashes : the adjustment failed. In this case, visually check the state of the pH probe, then attempt an adjustment again, several times if necessary. If the adjustment still fails, change the pH probe and perform a pH probe calibration.
    7. Press the left key twice to return to the default display.

Specification of basin volume

  • Possible settings : by code, according to the tables below.pooltech-PAPI004174-M-pH-Regulator-fig (27) pooltech-PAPI004174-M-pH-Regulator-fig (28) pooltech-PAPI004174-M-pH-Regulator-fig (29)
  • Default setting : pooltech-PAPI004174-M-pH-Regulator-fig (32).
    1. Make a long press on the right key until the messagepooltech-PAPI004174-M-pH-Regulator-fig (5) flashes.
    2. Press the up or down key x times until the messagepooltech-PAPI004174-M-pH-Regulator-fig (8) flashes.
    3. Press the right key : the flashing code corresponds to the basin volume recorded.
    4. Select a code with the up/down keys.
    5. Press the right key to validate : the selected code freezes briefly, then the message pooltech-PAPI004174-M-pH-Regulator-fig (8)flashes.
    6. Press the left key twice to return to the default display.

Alarms

Flashing display  

Fault detected

Immediate automatic action  

Checks and remedies

 

Acknowledgment

 

 

 

 

 

 

 

pH measurement

 

 

 

 

 

Difference of

+ or – 0.5

between the pH

measurement and the pH setpoint

 

 

 

 

 

 

 

 

–

Manually measure the pH with a recent test kit.

 If the value obtained corresponds to the

 value displayed :

a)    Switch off the electronics box.

b)    Pour the pH corrector (acidic if the pH is too high, or basic if the pH is too low) into the basin, near the delivery nozzles, so as to obtain a pH  of around 7.2.

c)    Wait 30 minutes.

d)    Restart the electronics box.

e)    Check that the pH measured by the electronics box is approximately 7.2.

 If      the     value      obtained     does     not

 correspond to the value displayed : Perform a pH probe calibration.

 

 

 

 

 

 

 

 

Automatic

 

 

 

 

pooltech-PAPI004174-M-pH-Regulator-fig (3)

 

 

 

Succession of several unsuccessful attempts to correct the pH

 

 

pH regulation stopped

–    Check that the pH corrector container is not empty. If the container is empty, replace it then perform a manual injection of pH corrector.

–    Check the condition of the ballast  filter and the injection connector.

–    Carry out a calibration of the pH probe.

 

 

Press

the right key

GUARANTEE

Before contacting your dealer, please have the following to hand :

  • your purchase invoice.
  • the serial no. of the electronics unit.
  • the installation date of the equipment.
  • the parameters of your pool (salinity, pH, chlorine levels, water temperature, stabilizer level, pool volume, daily filtration time, etc.).

Every effort and all our technical experience has gone into designing this equipment. It has been subjected to quality controls. If, despite all the attention and expertise involved in its manufacture, you need to make use of our guarantee, it only applies to free replacement of the equipment’s defective parts (excluding shipping costs in both directions).

Guarantee period (proven by date of invoice)

  • Electronics box : 2 years.
  • pH probe : depending on model.
  • Repairs and spare parts : 3 months.
    The periods indicated above correspond to standard guarantees. However, these can vary depending on the country of installation and the distribution network.

Scope of the guarantee
The guarantee covers all parts, with the exception of wearing parts that must be replaced regularly. The equipment is guaranteed against all manufacturing defects within the strict limitations of normal use.
After-sales services
All repairs will be performed in the workshop.
Shipping costs in both directions are at the user’s own expense.
Any downtime and loss of use of a device in the event of repairs shall not give rise to any claim for compensation.
In all cases, the equipment is always sent at the user’s own risk. Before taking delivery, the user must ensure that it is in perfect condition and, if necessary, write down any reservations on the shipping note of the carrier. Confirm with the carrier within 72 hours by recorded letter with acknowledgement of receipt.
Replacement under guarantee shall in no case extend the original guarantee period.
Guarantee application limit
In order to improve the quality of their products, the manufacturer reserves the right to modify the characteristics of the products at any time without notice. This documentation is provided for information purposes only and is not contractually binding with respect to third parties. The manufacturer’s guarantee, which covers manufacturing defects, should not be confused with the operations described in this documentation.
Installation, maintenance and, more generally, any servicing of the manufacturer’s products should only be performed by professionals. This work must also be carried out in accordance with the current standards in the country of installation at the time of installation. The use of any parts other than original parts voids the guarantee ipso facto for the entire equipment.
The following are excluded from the guarantee :

  • Equipment and labour provided by third parties in installing the device.
  • Damage caused by installation not in compliance with the instructions.
  • Problems caused by modifications, accidents, misuse, negligence of professionals or end users, unauthorised repairs, fire, floods, lightning, freezing, armed conflict or any other force-majeure events.

Any equipment damaged due to non-compliance with the instructions regarding safety, installation, use and maintenance contained in this documentation will not be covered by the guarantee.
Every year, we make improvements to our products and software. These new versions are compatible with previous models. The new versions of hardware and software cannot be added to earlier models under the guarantee.
Implementation of the guarantee
For more information regarding this guarantee, contact your dealer or our After-Sales Service. All requests must be accompanied by a copy of the purchase invoice.
Legislation and disputes
This guarantee is subject to French law and all European directives or international treaties in force at the time of the claim, applicable in France. In case of disputes concerning its interpretation or execution, the High Court of Montpellier (France) shall have exclusive jurisdiction.

FAQs

Q: How do I adjust the pH measurement?

  • A: To adjust the pH measurement, follow the steps outlined in the calibration section of the user manual.

Q: What should I do if the red indicator light is blinking?

  • A: The blinking red indicator light may indicate an alarm condition. Refer to the alarm section of the user manual for further instructions.

Documents / Resources

PDF thumbnailPAPI004174-M pH Regulator
Instruction Manual · PAPI004174-M pH Regulator, PAPI004174-M, pH Regulator, Regulator

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.