Series 700 Surface Mount Backbox Red

1. Koniec produktuview

The Mircom Technologies MRM-700 is a Series 700 Surface Mount Backbox, designed for use with compatible fire safety equipment. This red backbox provides a secure and accessible enclosure for various fire alarm system components, ensuring proper installation and protection.

White box with 'Mircom Technologies MRM-700' printed on it

Rysunek 1: Packaging of the Mircom Technologies MRM-700 Surface Mount Backbox. The box is white with the product name and model number clearly visible.

2. Konfiguracja i instalacja

This section provides general guidelines for setting up and installing the MRM-700 backbox. Always refer to local building codes and the specific installation instructions for the device being housed within the backbox.

2.1. Wymagane narzędzia

2.2. Instrukcje montażu

  1. Wybierz lokalizację: Choose a suitable surface for mounting, ensuring it is flat, stable, and free from obstructions. Consider accessibility for future maintenance.
  2. Oznacz punkty mocowania: Use the backbox as a template to mark the desired mounting screw locations on the surface. Ensure the marks are level.
  3. Drill Pilot Holes (if necessary): If mounting to a wall or hard surface, drill pilot holes at the marked locations. Use appropriate drill bit size for your screws and wall anchors.
  4. Secure Backbox: Align the backbox with the pilot holes (or marks) and secure it firmly using appropriate screws. Do not overtighten.
  5. Zainstaluj urządzenie: Once the backbox is securely mounted, proceed with installing the intended fire safety device (e.g., pull station, horn/strobe) inside the backbox according to its specific instructions.

3. Zasady działania

The MRM-700 is a passive component designed to house and protect active fire safety devices. It does not have operational controls itself. Its function is to provide a secure, surface-mounted enclosure for devices such as manual pull stations, notification appliances, or other compatible fire alarm system components.

Operation of the overall fire safety system will depend on the specific device installed within this backbox. Refer to the instruction manual of the device housed within the MRM-700 for its operational details.

4. Konserwacja

The MRM-700 backbox requires minimal maintenance. Regular inspection is recommended to ensure its integrity and proper function as an enclosure.

4.1. Czyszczenie

4.2. Kontrola

5. Rozwiązywanie Problemów

As a passive enclosure, the MRM-700 backbox itself typically does not experience "malfunctions." Troubleshooting primarily involves addressing issues related to its physical integrity or installation.

ProblemMożliwa przyczynaRozwiązanie
Backbox is loose on mounting surfaceMounting screws are loose or insufficient.Tighten existing screws. If necessary, use larger screws or appropriate wall anchors.
Visible damage (cracks, dents)Physical impact or stress.Inspect the extent of damage. If structural integrity is compromised, replace the backbox.
Device inside backbox is not secureImproper installation of the device within the backbox.Refer to the installation instructions for the specific device and ensure it is correctly mounted within the MRM-700.

6. Specyfikacje

7. Informacje o gwarancji

Mircom Technologies products are typically covered by a limited warranty. For specific warranty terms and conditions applicable to the MRM-700, please refer to the official Mircom Technologies webOdwiedź witrynę lub skontaktuj się z działem obsługi klienta. Zachowaj paragon jako dowód zakupu.

8. Obsługa klienta

For technical assistance, product inquiries, or support regarding the Mircom Technologies MRM-700, please contact Mircom Technologies directly.

Producent: MIRKOM

Please visit the official Mircom Technologies website for the most current contact information, including phone numbers, email addresses, and support resources.

Powiązane dokumenty - MRM-700

Przedview Mircom FA-101U Fire Alarm Control Panel: Installation and Operation Manual
This manual provides detailed installation, operation, and troubleshooting guidance for the Mircom FA-101U Fire Alarm Control Panel. It covers features, wiring diagrams, indicator functions, sequence of operations, system checkout, and compatible devices.
Przedview Mircom XAL-53 – przeciwwybuchowa stacja alarmowa | Dane techniczne
Szczegółowe specyfikacje i funkcje przeciwwybuchowej stacji alarmowej Mircom XAL-53, przeznaczonej do zastosowań w strefach zagrożonych wybuchem. Zawiera dane operacyjne, klasyfikacje i parametry elektryczne.
Przedview Mircom FA-300 Series LCD Fire Alarm Control Panel Installation and Operation Manual
This manual provides detailed installation and operation instructions for the Mircom FA-300 Series LCD Fire Alarm Control Panel, covering its features, indicators, buttons, on-screen messages, and common troubleshooting scenarios.
Przedview Instrukcja instalacji i obsługi obudowy śluzy pocztowej TX3-PL-ENCL
W niniejszym podręczniku opisano obsługę, wymiary i sposób instalacji obudowy śluzy pocztowej Mircom TX3-PL-ENCL przeznaczonej dla pracowników poczty.
Przedview Mircom MIX-M500RAPA Relay Control Module: Installation and Maintenance Guide
Comprehensive installation and maintenance instructions for the Mircom MIX-M500RAPA Relay Control Module, detailing specifications, wiring, mounting, and contact ratings for fire alarm systems.
Przedview Mircom MIX-4046 Multi-Use Output Module: Installation and Maintenance Instructions
Comprehensive guide for installing and maintaining the Mircom MIX-4046 Multi-Use Output Module, detailing its features, specifications, and wiring configurations for fire alarm systems.