The ZOYI ZT-R02 is an innovative 2-in-1 device that combines the functionality of a high-precision digital multimeter with an advanced infrared thermal imaging camera. Designed for professionals and enthusiasts alike, it offers dual-mode smart diagnostics to rapidly pinpoint overheating or undercooling spots while simultaneously performing precise electrical measurements. This manual provides detailed instructions for safe and effective use of your ZT-R02.

Two ZOYI ZT-R02 units demonstrating dual functionality as a multimeter and thermal imaging camera.

Figure 1: ZOYI ZT-R02 highlighting its dual multimeter and thermal imaging capabilities.

2. Informacje dotyczące bezpieczeństwa

Please read and understand all safety information before operating the ZOYI ZT-R02. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Przed użyciem należy zawsze upewnić się, że urządzenie jest w dobrym stanie technicznym.
  • Nie należy używać urządzenia, jeśli wygląda na uszkodzone lub jeśli przewody pomiarowe są uszkodzone.
  • Podczas pracy z prądem elektrycznym należy zachować wszelkie środki ostrożności, w tym stosować odpowiedni sprzęt ochrony osobistej (PPE).
  • Nie należy przekraczać maksymalnych wartości wejściowych określonych dla każdej funkcji pomiarowej.
  • Przed dokonaniem pomiarów należy upewnić się, że wybrano właściwą funkcję i zakres.
  • Unikaj używania urządzenia w wilgotnym otoczeniu lub w obecności wybuchowych gazów lub pyłów.
  • Ten produkt posiada certyfikat CE, który potwierdza zgodność z europejskimi normami bezpieczeństwa.

3. Zawartość opakowania

Sprawdź, czy w przesyłce znajdują się wszystkie elementy:

  • ZOYI ZT-R02 Main Unit x 1
  • Test Probes x 1 pair
  • Kabel do ładowania USB x 1
  • Instrukcja obsługi x 1
  • Storage Pouch x 1 (typically included for protection)
Image showing the ZOYI ZT-R02 main unit, test probes, USB charging cable, user manual, and a storage pouch.

Figure 2: Contents of the ZOYI ZT-R02 package.

4. Koniec produktuview

The ZOYI ZT-R02 integrates multiple functions into one device, delivering comprehensive diagnostic capabilities. It features a 2.4-inch TFT color display for clear readability and a robust design for field use.

Główne cechy:

  • Dual-Mode Smart Diagnostics: Instantly switch between thermal imaging and multimeter modes.
  • High-Definition Infrared Imaging: 96 x 96 pixel VOx sensor, 240 x 240 pixel display resolution, 25 Hz frame rate.
  • Szeroki zakres temperatur: Measures from -20°C to 550°C with ±2% accuracy.
  • Triple-Point Temperature Measurement & Auto-Tracking: Displays center, highest, and lowest temperature points.
  • 8 Pseudo-Color Palettes: For clear temperature distribution visualization.
  • High-Precision Digital Multimeter: 25,000-count accuracy with True RMS for various electrical measurements.
  • 2.4-calowy pełnyView Kolorowy ekran: Ensures clear data and image display from any angle.
  • Field-Ready Design: Ergonomic, lightweight, portable, with a built-in rechargeable lithium battery.
ZOYI ZT-R02 key features summary including display size, resolution, measurement range, and color palettes.

Figure 3: Summary of ZOYI ZT-R02 key features.

Nadview of ZOYI ZT-R02 Thermal Imaging Multimeter Functions, including AC/DC Voltage, Current, Resistance, Capacitance, True RMS, Data Hold, Frequency, 4½-digit display, Infrared Thermal Imaging, Firmware Upgrade, Full-Angle Color Screen, and Data Transfer.

Figure 4: Detailed list of functions integrated into the ZT-R02.

5. Specyfikacje

ZT-R02 Thermal Imaging Multimeter Specifications: Detailed technical specifications for both multimeter and thermal imaging camera functions.

Figure 5: Visual representation of ZT-R02 technical specifications.

Thermal Imaging Section:

Parametr Wartość
Rozdzielczość w podczerwieni96x96
Rozdzielczość wyświetlacza240x240
Szybkość klatek25 Hz
Zakres temperatur-20°C do 550°C
Dokładność temperatury±2%
Palety8 do wyboru
EmisyjnośćRegulowany 0.01-1.00
Metoda ogniskowaniaFocus-Free / Display Resolution: 320*240
Pole View50.0° (H) × 50° (V) / 72.1° (D)
Efektywna odległość pomiaru0.3-50m (configurable)
Punkt pomiaruPunkt środkowy
Strefy pomiaru temperatury3 (Highest Temp, Real-time Temp, Lowest Temp)
Paleta kolorówBiały gorący, Czarny gorący, Niebieski, Żelazna czerwień, Kolor, Czerwony gorący, Fuzja, Tęcza

Multimeter Section:

Parametr Wartość
Rozdzielczość wyświetlacza25,000 liczy
AC Objętośćtage0~750 V
Objętość DCtage0~1000 V
Prąd AC/DC0~10A
Opór0~250MΩ
Pojemność0~99.99mF
Częstotliwość0 ~ 999.9 kHz
Test DiodyTak
Sygnał dźwiękowy ciągłościTak
Ocena bezpieczeństwaCAT III

Dane ogólne:

Parametr Wartość
Wyświetlacz2.4-calowy kolorowy ekran TFT
ZasilaczWbudowana bateria litowa o pojemności 2000 mAh
InterfejsUSB (do ładowania i przesyłania danych)
Wymiary149mm x 76mm x 33.5mm
WagaOkoło 193g
TworzywoABS+TPE
Strona view of the ZOYI ZT-R02 with its kickstand extended, showing its physical dimensions.

Figure 6: ZOYI ZT-R02 dimensions.

6. Konfiguracja

6.1 Ładowanie urządzenia

The ZT-R02 comes with a built-in rechargeable lithium battery. Before first use, or when the battery indicator shows low power, charge the device using the provided USB charging cable.

  1. Connect the small end of the USB cable to the USB port on the ZT-R02.
  2. Podłącz większy koniec kabla USB do standardowego zasilacza USB (nie ma go w zestawie) lub do portu USB komputera.
  3. The charging indicator on the device will show the charging status. Allow the device to charge fully before use.

6.2 Włączanie/wyłączanie

  • Aby włączyć: Naciśnij i przytrzymaj przycisk zasilania (czerwony okrąg z symbolem mocy) aż ekran się zaświeci.
  • To power off: Press and hold the power button until the screen turns off. The device also features an auto-power off function to conserve battery.

6.3 Podłączanie sond testowych

For multimeter functions, connect the test probes to the appropriate input jacks on the device:

  • Włóż czarny przewód pomiarowy do gniazda „COM” (wspólnego).
  • Włóż czerwony przewód pomiarowy do gniazda „VΩHz”, aby uzyskać pomiar głośności.tagpomiary rezystancji, częstotliwości i pojemności.
  • For current measurements, insert the red test lead into the '10A MAX' jack for high current or '250mA MAX' jack for low current, depending on the expected value.

7. Instrukcja obsługi

7.1 Switching Modes (Multimeter / Thermal Imaging)

The ZT-R02 allows for quick switching between its two primary modes:

  • Press the 'IR DMM' button to toggle between the Infrared Thermal Imaging mode and the Digital Multimeter mode.
2-in-1 Thermal Imaging Multimeter Display Modes: Demonstrates the device's ability to switch between thermal imaging and digital multimeter displays.

Figure 7: Switching between thermal imaging and multimeter displays.

7.2 Praca w trybie multimetru

In Multimeter mode, use the rotary dial and function buttons to select the desired measurement type.

  1. Tomtage (prąd przemienny/stały): Turn the dial to 'V~' for AC voltage lub 'V=' dla prądu stałegotage. Connect probes in parallel to the circuit.
  2. Prąd (AC/DC): Turn the dial to 'A~' for AC current or 'A=' for DC current. Connect probes in series with the circuit. Ensure correct current input jack is used.
  3. Rezystancja (Ω): Turn the dial to 'Ω'. Connect probes across the component.
  4. Pojemność (F): Turn the dial to 'F'. Connect probes across the capacitor (ensure it's discharged).
  5. Częstotliwość (Hz): Turn the dial to 'Hz'. Connect probes to the signal source.
  6. Test diody: Turn the dial to the diode symbol. Connect probes across the diode.
  7. Test ciągłości: Turn the dial to the continuity symbol. Connect probes across the circuit to check for continuity (a beep indicates continuity).
High-Precision 25,000-Count Multimeter in Use: Shows the multimeter probes connected to a circuit board, illustrating its capability to measure various electrical parameters.

Figure 8: Multimeter probes connected for electrical measurement.

7.3 Thermal Imaging Mode Operation

In Thermal Imaging mode, the device displays a thermal map of the environment.

  1. 3-Point Temperature Measurement: The screen automatically displays the temperature at the center point, the highest temperature (MAX), and the lowest temperature (MIN) within the field of view. This feature is ideal for identifying hot or cold spots quickly.
  2. Automatyczne śledzenie: The device automatically captures and tracks abnormal temperature points, making it efficient for diagnostics.
Hot and Cold Tracking: Illustrates the 3-point temperature measurement feature, showing center, maximum, and minimum temperature points on the thermal display.

Figure 9: 3-point temperature measurement and hot/cold tracking.

7.4 Palety kolorów

The ZT-R02 offers 8 pseudo-color palettes to visualize temperature distribution. You can switch between these palettes via the 'MENU' button to find the most suitable display for your application.

8 Pseudo-Color Modes for Thermal Imaging: Displays various color palettes available for thermal visualization, aiding in troubleshooting and detection.

Rysunek 10: Examples of the 8 pseudo-color palettes.

7.5 Zatrzymanie danych

Press the 'HOLD' button to freeze the current measurement reading on the display. Press it again to release and resume live readings.

7.6 Przesyłanie danych

The device supports data transfer via its USB interface. Connect the ZT-R02 to a computer using the USB cable to access stored images or measurement data for further analysis.

7.7 Scenariusze aplikacji

  • Konserwacja instalacji elektrycznych: Locate circuit overloads, loose connections, and faulty components by identifying abnormal heat signatures.
  • Systemy HVAC: Diagnose heating/cooling system faults, detect pipe leaks (e.g., underfloor heating), and assess insulation efficiency.
  • Konserwacja pojazdów: Troubleshoot engine overheating, brake system faults, and electrical issues in vehicles.
  • Konserwacja domu: Inspect door/window insulation, locate wall water leaks, and identify areas of energy loss.
Underfloor Heating Pipe Leak Detection: Shows the ZT-R02 being used to detect leaks in underfloor heating pipes, with a four-step guide for testing.

Figure 11: ZT-R02 in action for underfloor heating leak detection.

8. Konserwacja

8.1 Czyszczenie

  • Wyczyść urządzenie casing z miękkim, damp ściereczka. Nie należy używać środków czyszczących o właściwościach ściernych ani rozpuszczalników.
  • Keep the thermal lens and display screen clean and free from dust and debris. Use a lens cleaning cloth if necessary.

8.2 Pielęgnacja baterii

  • Aby zachować sprawność baterii, ładuj ją regularnie, nawet jeśli nie używasz urządzenia często.
  • Unikaj całkowitego rozładowania akumulatora na dłuższy czas.
  • Przechowuj urządzenie w chłodnym, suchym miejscu, gdy nie jest używane.

8.3 Przechowywanie

When storing the ZT-R02, place it in its protective pouch to prevent scratches and damage. Avoid exposing it to extreme temperatures or humidity.

9. Rozwiązywanie Problemów

  • Urządzenie się nie włącza: Upewnij się, że bateria jest wystarczająco naładowana. Podłącz ją do źródła zasilania USB i spróbuj ponownie.
  • Niedokładne odczyty multimetru: Check that the test probes are correctly connected and that the correct function and range are selected. Ensure probes are making good contact.
  • Thermal image unclear: Clean the thermal lens. Ensure the emissivity setting is appropriate for the material being measured.
  • Ekran zamrożony: Spróbuj ponownie uruchomić urządzenie, przytrzymując przycisk zasilania. Jeśli problem będzie się powtarzał, skontaktuj się z pomocą techniczną.
  • Brak transferu danych: Ensure the USB cable is securely connected to both the device and the computer. Check computer's device manager for recognition.

10. Wskazówki użytkownika

  • Regulacja emisyjności: For accurate thermal readings, adjust the emissivity setting to match the surface material you are inspecting. Different materials emit infrared energy differently.
  • Background Temperature: Be aware of reflective surfaces in the background, as they can influence thermal readings.
  • Analiza porównawcza: When troubleshooting, compare thermal images of a faulty component or area with a known good one to easily spot anomalies.
  • Regularne aktualizacje oprogramowania sprzętowego: Sprawdź producenta webOdwiedzaj tę witrynę okresowo w celu uzyskania aktualizacji oprogramowania sprzętowego, aby zapewnić optymalną wydajność i dostęp do nowych funkcji.
  • Practice with Known Values: Before critical measurements, practice with known voltage sources or temperature references to familiarize yourself with the device's operation and accuracy.

11. Gwarancja i wsparcie

The ZOYI ZT-R02 is backed by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms, duration, and to obtain technical support or service, please refer to the warranty card included with your product or contact the seller/manufacturer directly. Keep your purchase receipt as proof of purchase.