- Operating mode: Direct Mode
- Power Consumption: 0.2mW
- Battery Life: Approx. 200 operating hours at the point of production (approx. 2 years if used 10 minutes per day)
- Transient response time: 40s
Product Usage Instructions
- Press the on-off button to turn on the thermometer. The window will display and a beep sound will be heard, indicating that the unit is in working condition.
Taking Temperature - Release the on-off button to view the last measured temperature briefly. The display will then flash, indicating the thermometer is ready to take a temperature.
- Temperature can be taken orally, underarm, or rectally.
Follow the specific instructions for each method:- Oral Use: Place the sensor tip beneath the tongue until a beep sound is heard. Remove the thermometer to read the temperature on the display.
- Rectal Use: Lubricate the tip with water-soluble jelly, gently insert it into the rectum, and hold until a beep sound is heard. Remove the thermometer to read the temperature on display.
Temperature Reading and Power Off
- When the peak temperature is reached, an alarm will sound.
Press the on-off button to turn off the power. The thermometer will automatically power off after about 8 minutes if left unused. - For immediate re-use, turn off the power first, then press the on-off button again to restart the measurement process.
CAUTION
The body temperature may vary due to various factors. It is recommended to take your temperature consistently over several days to establish your normal body temperature.
WARNING
- Temperatures should be taken under adult supervision and kept away from children.
- Avoid biting the sensor tip during oral temperature measurement.
- Avoid bending, dissembling, pulling, or dropping the unit.
- Avoid direct sunlight, high temperature, high humidity, dirt, and strong electrostatic or electromagnetic waves.
Frequently Asked Questions (FAQ)
- Q: How do I clean the thermometer?
A: Use a soft cloth with alcohol to clean the sensor tip after each use. - Q: Can I use the thermometer for both adults and children?
A: Yes, this thermometer can be used for individuals of all ages with appropriate precautions.
Digital Thermometer (with soft tip)
MODEL NO. 79559 (MT905) 80087
SPECIFICATIONS
- Operating mode Power Consumption
- Direct Mode 0.2mW
- Battery Life Transient response time 40s
- Approx. 200 operating hours at the point of production (approx. 2 years if used 10 minutes per day)
- Display Unit 0.01oC/0.01°F
- Measuring Range
- 32.00oC – 42.99oC/90.00°F – 109.90°F
- (if less than 32.00oC/90.00°F,
displays)
- (if more than 42.99oC/109.90°F,
displays)
Accuracy
- ± 0.1oC/± 0.2°F between
- 35.0oC – 42.0oC/95.0°F-107.9°F
- at room temperature (22oC/71.6°F)
- ± 0.2oC/±0.4°F for other measuring and room temperature range.
HOW TO USE
How to change between Centigrade and Fahrenheit readings: Activate unit and hold down on/off button for more than 2 seconds.
- Press the on-off button to turn on the thermometer. The window will display
and a beep sound will be heard. This indicates that the unit is in working condition.
- Upon releasing the on-off button, the last measured temperature will be shown for about two seconds then
display will flash (If the room temperature is higher than 32oC, the actual room temperature will be displayed instead). The flashing
indicates that the thermometer is ready to take a temperature.
- Temperature can be taken ORALLY, UNDERARM (AXILLARY) OR RECTALLY.
- ORAL USE:
Put the sensor tip beneath the tongue and close your mouth until a beep sound is heard (for about one minute). Remove the thermometer and read the temperature on the display. - UNDERARM (AXILLARY) USE:
Wipe armpit with a dry towel. Place the sensor tip under the armpit, press down the lower arm and hold firmly. When temperature is stabilized, a beep sound will be heard. In axillary use, it is recommended to ignore the completion beeps and keep the thermometer in place for more than 5 minutes. Then remove the thermometer and read the temperature on the display. To avoid any influence from surrounding air, fold the arm over the chest, tightly covering the sensor under the arm. - RECTAL USE:
- Lubricate the tip of the thermometer with a water-soluble jelly for easier insertion. Do not use petroleum jelly.
- The patient should lay on his/her side, with knees slightly bent. If the patient is a baby, place the baby on his stomach with the legs hanging down in a 90o angle. This positions the baby’s rectum properly for safe and easy insertion of the thermometer.
- Gently insert the tip of the thermometer, NO MORE THAN 1.2CM (1/2inch), into the rectum. If you feel any resistance, STOP insertion.
- Hold the thermometer in place until a beep sound is heard. Remove the thermometer and read the temperature on display.
- Once used rectally, the thermometer should not be used orally for sanitary reasons.
- ORAL USE:
- When the peak temperature is reached or temperature stabilizes, the
symbol stops flashing and sounds an alarm Bi—Bi—Bi. If the detected temperature exceeds 37.8oC, it sounds a rapid Bi-Bi-Bi—Bi-Bi-Bi.
- Press the on-off button to turn off the power. If you forget to turn off the thermometer, it will turn off the power automatically in about 8 minutes.
- For immediate re-use, please press the on-off button to turn off the power first, then press the on-off button again to re-start the measurement process.
CAUTION
The body temperature will differ depending on the time of day, food you have eaten, recent exercise, the method used to take your temperature (orally, underarm or rectally), medication and environmental factors such as the external temperature. You are recommended to take your temperature in the same method over several days and become familiar with your normal body temperature.
WARNING
- Temperatures should be taken under adult supervision and stored away from the reach of children.
- Do not bite the sensor tip while taking oral temperatures. Simply place the tip under the tongue.
- Do not bend on purpose, dissemble, pull or drop the unit.
- Avoid exposing the thermometer to direct sunlight, high temperature, high humidity or dirt.
- Keep away from strong electrostatic or electromagnetic waves (eg., near TV, microwave oven or cellular phone).
- Stop using the thermometer if it is broken.
- Do not disassemble or repair the unit except to replace the battery.
- Remove the battery if the thermometer is not likely to be used for a year.
- Follow cleaning instructions. Do not wash in any way other than instructed. Always keep the sensor tip clean.
HOW TO CLEAN
Wash the waterproof area extending about 5cm (2inch) from the tip of the thermometer with warm soap water or wipe the area with 70% isopropyl alcohol before and after each use. Dry thermometer thoroughly before storing in the case provided with the unit.
HOW TO REPLACE THE BATTERY
When the battery is almost exhausted, the sign will be shown in the display window. Replace with a new battery before the current battery is completely exhausted.
- Remove the battery cover by using a small “-” shape driver to push front lip of the cover upwards.(see diagram A).
- Remove the battery.
- Insert the new battery (see diagram B).
NOTE: Ensure battery polarity is correctly placed. The battery should be inserted with the positive side(+) facing up. - Replace and fasten the cover firmly.
Operating Condition | Storage and Transportation Condition | |
Temperature | :10°C ~ 40°C (50°F~104°F) | -20°C ~ 55°C (-4F~131F) |
Relative Humidity | 15% – 95% RH | 15% – 95% RH |
Atmospheric pressure | 700hPa – 1060hPA | 500hPa – 1060hPA |
WARNING:
- Swallowing a button battery may be fatal.
- Do not attempt to recharge the battery.
- Do not dispose the battery in or near fire as it may explode.
- Exhausted batteries should never be disposed of in household waste but must be handed in at your local depot for chemical waste.
Item | Description |
![]() |
Indicates incorrect handling that cause major injury |
![]() |
Insulation type: BF equipment |
![]() |
EU environmental protection directive |
![]() |
Suggest to read the manual |
![]() |
Manufacturer name and address |
Acute Ideas Co. Ltd., 3F No.11, Lane 35, Jihu Road, Neihu District, Taipei 114, Taiwan
APPENDIX EMC
WARNINGS:
- The instrument conforms to the requirements of IEC60601-1-2, standards for electromagnetic compatibility.
- The user shall install and use the EMC information provided in the random file.
- Portable and mobile RF communication equipment may affect the performance of the instrument, avoid strong electromagnetic interference when using, such as close to the mobile phone, microwave oven, etc.
- The guidance and manufacturer’s declaration are detailed in the table below.
- The instrument should not be close to or stacked with other equipment. If it must to be close to or stacked, it should be observed and verified to be able to operate normally under its configuration.
- In addition to the cables sold by the instrument manufacturer as spare parts for internal components, the use of other accessories and cables may result in increased emission or reduced immunity.
TABLE 1
Guidance and manufacturer’s declaration-electromagnetic emission | ||
The Digital Thermometer is intended for use in the electromagnetic environment specified below. The customer or the user of the Digital Thermometer should assure that it is used in such an environment. | ||
Emissions test | Compliance | Electromagnetic environment-guidance |
Conducted emissions CISPR 11 | N/A | The Digital Thermometer uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electonic equipment. |
Radiated emissions CISPR 11 | Group 1 Class B | |
Harmonic emissions IEC61000-3-2 | N/A | The Digital Thermometer suitable for use in all establishments, including domestic establishments and those directly network that supplies buildings used for domestic purposes. |
Voltage fluctuations / flicker emissions IEC61000-3-3 | N/A |
TABLE 2
Guidance and manufacturer’s declaration-electromagnetic emission | |||
The Digital Thermometer is intended for use in the electromagnetic environment specified below. The customer or the user of the Digital Thermometer should assure that it is used in such an environment. |
|||
Immunity test | IEC60601 test level | Compliance level | Electromagnetic environment -guidance |
Electrostatic discharge(ESD) IEC61000-4-2 |
|
|
Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30% |
Electrical fast transient/ burst IEC61000-4-4 |
|
N/A | Mains power quality should be that of a typical commercial or hospital environment. |
±1 kV for Signal Input/output Ports | |||
Surge IEC 61000-4-5 |
|
N/A | Mains power quality should be that of a typical commercial or hospital environment. |
Voltage dips, | <5% UT | Mains power quality | |
short | (>95% dip in UT) | should be that of a typical | |
interruptions | for 0.5 cycle | commercial or hospital | |
and voltage | <40% UT | Environment .If the user of | |
variations on | (60% dip in UT) | Digital Thermometer | |
power supply
input lines |
for 5 cycles
<70% UT |
N/A |
requires continued operation
during power mains |
IEC61000-4-11 | (30% dip in UT) | interruptions, it is | |
for 25 cycles | recommended that Digital | ||
<5% UT | Thermometer should be | ||
(>95% dip in UT) | powered from an | ||
for 5 s | uninterruptible power supply | ||
or a battery | |||
Power frequency (50Hz/60Hz) magnetic field IEC61000-4-8 | 30A/m |
30A/m |
Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. |
NOTE: UT is the a.c. mains voltage prior to application of the test level. |
Guidance and manufacturer’s declaration – electromagnetic immunity | |||
The Digital Thermometer is intended for use in the electromagnetic environment specified below. The customer or the user of The Digital Thermometer should assure that it is used in such an electromagnetic environment. | |||
Immunity test | IEC60601 test level | Compliance level | Electromagnetic environment -guidance |
Conducted RF IEC61000-4-6
Radiated RF IEC61000-4-3 |
0,15MHz–80MHz 3 V RMS outside the ISM band, 6 V RMS in the ISM and ama-teur radio bands
10V/m 80 MHz to 2.7 GHz |
N/A
10V/m |
|
|
|||
|
Frequency Range and Level: RF wireless communication equipment | |||
Test Frequency (MHz) |
Modulation |
Minimum immunity Level (V/m) | immunity Level Applied (V/m) |
385 |
**Pulse Modulation: 18 Hz |
27 |
27 |
450 |
*FM + 5 Hz deviation: 1 kHz sine **Pulse Modulation: 18 Hz |
28 |
28 |
710
745 780 |
**Pulse Modulation: 217 Hz |
9 |
9 |
810
870 930 |
**Pulse Modulation: 18 Hz |
28 |
28 |
1720
1845 1970 |
**Pulse Modulation: 217 Hz |
28 |
28 |
2450 |
**Pulse Modulation: 217 Hz |
28 |
28 |
5240
5500 5785 |
**Pulse Modulation: 217 Hz |
9 |
9 |
ATTENTION:
|
For transmitters rated at a maximum output power not listed above, the recommended separation distance in metres (m) can be determined using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
- NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
- NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
Documents / Resources
![]() |
pigeon 80087 Digital Thermometer with Soft Tip [pdf] Instruction Manual 80087, 80087 Digital Thermometer with Soft Tip, Digital Thermometer with Soft Tip, Thermometer with Soft Tip, Soft Tip, Tip |