Phason DOL119 Plus Touch Controller User Guide

Phason DOL119 Plus Touch Controller User Guide
Phason DOL119 Plus Touch Controller

Product Overview

Product Overview

  • (A) Display cable
    Disconnect the cable during installation. Reconnect it when done.
  • Warning Icon (B) Voltage switch
    Set the switch to the correct line voltage.
  • (C) Incoming power
    Connect the incoming power from the panel.
  • (D) Temperature sensor (TEMP1 to TEMP4)
    Connect the primary temperature sensor to TEMP1. Connect any additional sensors to the other terminals.
  • (E) Actuator feedback (ACT-1 and ACT-2)
    Connect the feedback potentiometer from the actuator.
  • (F) Alarm relay
    Connect an external alarm system or siren.
  • (G) General-purpose relays (STG-1 to STG-6)
    Connect single-speed/stage heating/cooling equipment.
  • (H) Variable stages (VAR-1 and VAR-2)
    Connect variable speed fans. (I)Fuses (F1 and F2)
    The fuses are for the variable stages. F1 is for VAR-1 F2 is for VAR-2.
  • (J) USB
    Connect a USB drive when saving or loading settings, or updating firmware.
  • (K) OUTDOOR
    Connect a Phason 3K Temperature Sensor for measuring outdoor temperature.
  • (L) +5V
    Can provide +5 VDC
  • (M) DOL (M: AUX1 to AUX3)
    Connect DOL119 Carbon Dioxide or DOL 53 Ammonia Sensors.
    Place the jumpers on the correct pins.
  • (N) DOL 114 (TEMP / HUM)
    Connect a DOL 114 Temperature and Humidity Sensor.
    Place the jumpers on the correct pins.
  • (O) Pulse counter (COUNT)
    Not available, used for future development.

Input power
120/230 VAC, 50/60 Hz

Fuses (2: F1 and F2)
15 A, 250 VAC ABC-type ceramic

Variable stages (2: VARI-1, VARI-2)
10 A at 120/230 VAC, general-purpose (resistive)
7 FLA at 120/230 VAC, PSC motor
1/2 HP at 120 VAC, 1 HP at 230 VAC, PSC motor

Relay stages (6: STG-1 to STG-6)
10 A at 120/230 VAC, general-purpose (resistive)
1/3 HP at 120 VAC, 1/2 HP at 230 VAC
360 W tungsten at 120 VAC

Alarm relay
0.4 A at 125 VAC; 2 A at 30 VDC, resistive load
0.2 A at 125 VAC; 1 A at 30 VDC, inductive load

  • Mounting holes and orientation
    Mounting holes and orientation
  • Incoming power
    Incoming power
  • Single-speed fan or electric heater
    Single-speed fan or electric heater
  • Gas-fired furnace
    Gas-fired furnace
  • Variable speed fan
    Variable speed fan
  • Correct three-phase wiring
    Correct three-phase wiring
  • Incorrect three-phase wiring
    Incorrect three-phase wiring
  • Curtain machine
    Curtain machine
  • DC-powered actuator
    DC-powered actuator
  • AC-powered actuator
    AC-powered actuator
  • Temperature sensor
    Temperature sensor
  • DOL 114 temperature and humidity
    DOL 114 temperature and humidity
  • DOL 119 carbon dioxide
    DOL 119 carbon dioxide
  • DOL 53 ammonia
    DOL 53 ammonia
  • Normally open alarm system
    Normally open alarm system
  • Normally closed alarm system
    Normally closed alarm system

www.phasoncontrols.com
sales@phasoncontrols.com
Toll-free North America: 800-590-9338
International: 204-233-1400

Documents / Resources

PDF thumbnailDOL119 Plus Touch Controller
User Guide · DOL119 Plus Touch Controller, DOL119, Plus Touch Controller, Touch Controller, Controller

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.