PEDROLLO EASYPRESS Automatic Control Device

Product Information
Specifications:
- Type: P2
- Power: Single-phase 1.5 kW (2 HP)
- Power Supply: 230 Volt, 50/60 Hz
- Continuous Duty Current: 13 A
- Performance Range:
- Restart Pressure: 1.5 bar
- Maximum Volume Capacity: 170 l/min (10 m3/h)
Product Description:
- The EASYPRESS is an automatic control device designed for single-phase domestic pumps up to 2 HP. It features a pressure sensor and a flow sensor connected to an electronic system that activates the pump when pressure drops below a set level.
- The integrated electronics protect the pump from dry running, frequent start-ups due to leaks, and lockout due to inactivity.
Installation and Use:
- Ensure the power supply matches the device specifications.
- Connect the EASYPRESS to the pump according to the provided instructions.
- Adjust the restart pressure and other settings as needed.
- Monitor the LED indicators for system status and alerts.
- Maintain proper water flow to ensure optimal performance.
Accessories:
- GSR Special three-piece coupling with O-ring seal (1)
Dimensions and Weight:
- Version 1.5 bar: 11m maximum user height, weight 1.63 kg
- Version 0.8 bar: 5m maximum user height
- Version 2.2 bar: 18m maximum user height
FAQ:
- Q: How do I adjust the restart pressure on the EASYPRESS?
A: You can adjust the restart pressure by following the instructions provided in the user manual. Typically, it involves accessing the control panel and using specific buttons or settings to modify the pressure level. - Q: What should I do if the LED indicators show a blinking pattern?
A: A blinking pattern on the LED indicators indicates a specific issue with the system. Refer to the user interface guide to identify the problem associated with the blinking pattern and take appropriate action based on the guidance provided.
PERFORMANCE RANGE
- Restart pressure: 1.5 bar

- Maximum volume capacity: 170 l/min (10 m3/h)
INSTALLATION AND USE
EASY PRESS is a durable and reliable electronic device designed to control and safeguard single-phase domestic pumps with a power capacity up to 2 HP.

PRODUCT DESCRIPTION
- EASY PRESS features a pressure sensor and a flow sensor linked to an electronic system that automatically activates the pump when a faucet’s opening lowers the pressure below a specified level and deactivates it when the flow stops or dips under 2 l/min.
- The EASYPRESS is equipped with:
- Circuit board
- Pressure Gauge
- Integrated micro-accumulation enables operation even without an expansion tank, though the use of a 1SF tank is recommended.
The integrated electronics protect the pump from:
- dry running
- frequent start-ups due to leaks in the system;
- lockout due to plant inactivity.
DIMENSIONS AND WEIGHT

TECHNICAL DATA
| TYPE
Single-phase |
P2 | Power supply | Continuous duty current | ||
| kW | HP | Volt | Hz | ||
| EASYPRESS | 1.5 | 2 | 230 | 50/60 | 13 A |

The EASYPRESS features 2 LED indicators to show the system’s operating status and alert to any issues through blinking patterns. A guide on the user interface helps to identify specific problems indicated by the LEDs.
APPLICATION LIMITS
- Liquid temperature up to +55 °C
- Ambient temperature up to +40 °C
- Maximum operating pressure 10 bar
- Protection rating: IP 65
PATENTS – TRADE MARKS – MODELS
- Registered Community Model No. 868062
- Patent No. IT 1388969, IT 1388970
- EASYPRESS® registered trademark No. 0001334481
ACCESSORIES
- GSR Special three-piece coupling with o-ring seal (1″)

AVAILABLE UPON REQUEST
- EASYPRESS version with 0.8 bar restart pressure

- EASYPRESS version with restart pressure 2.2 bar

- Version with power cable with Schuko plug and motor pump connection cable
Documents / Resources
![]() | EASYPRESS Automatic Control Device |
References
- User Manualmanual.tools


Necesito ayuda .
Tengo un guardamotor en la línea a la que está conectada la bomba . Cuando salimos de casa quito la corriente a la bomba y dejo el easy Press conectado . Y aún así , al conectar de nuevo el guardamotor tengo que resetear el easypress . No hay manera de desconectar la bomba tener que rearmar luego el easyprees .
Gracias .
Tengo un guardamotor en la línea a la que está conectada la bomba . Cuando salimos de casa quito la corriente a la bomba y dejo el easy Press conectado . Y aún así , al conectar de nuevo el guardamotor tengo que resetear el easypress . No hay manera de desconectar la bomba tener que rearmar luego el easyprees .
Gracias .
How can I prevent the Pedrollo EASYPRESS from requiring a manual reset after the pump's motor protector is switched back on?
The Pedrollo EASYPRESS is designed to protect the pump from various issues, including dry running and frequent start-ups. When you disconnect the power to the pump via the motor protector but leave the EASYPRESS powered, the device may detect a lack of flow or pressure change when it attempts to start the pump, leading to a "Dry Running" or "Out of Service" lockout state.
To avoid having to manually reset the device every time, consider the following:
If the red "Status" LED is blinking or steady when you restore power, refer to the interface guide on the front of the device to identify if it is signaling "Dry Running" or "Frequent Start-up," as these states require a manual press of the START button to resume operation.
Read the full Q&A page
Dali je moguće smanjiti pritisak na Pedrollo easy press 2
Is it possible to reduce the pressure on the Pedrollo EASYPRESS 2?
No, it is not possible to manually adjust or reduce the pressure on the Pedrollo EASYPRESS. The device is an electronic controller with fixed factory settings.
The EASYPRESS operates based on a pre-set restart pressure. According to the manual, there are three distinct versions available depending on your needs, but these are fixed at the time of manufacture:
The device stops the pump when the flow rate drops below 2 liters per minute, meaning the maximum pressure reached in the system will always be the maximum pressure your specific pump is capable of delivering. If the pressure in your system is too high, you would need to install a separate pressure reducing valve on the outlet of the pump or choose a pump with a lower head pressure.
Read the full Q&A page
Pressure pump power blink what the problem
What does it mean when the power light on my Pedrollo EASYPRESS is blinking?
The Pedrollo EASYPRESS uses specific blinking patterns on its LED indicators to signal different operating statuses or faults. Based on the manual, here are the common causes for blinking lights:
To resolve this, try pressing the START button to manual reset the device. If the blinking persists, check for water supply issues (dry run) or leaks in your plumbing. For a precise diagnosis, compare the specific rhythm of the blink (fast, slow, or alternating with the Status LED) against the visual guide located on the front face of your EASYPRESS unit.
Read the full Q&A page
Cum măresc presiunea de oprire
How do I increase the stopping pressure on the Pedrollo EASYPRESS?
The Pedrollo EASYPRESS is an electronic flow and pressure sensor device that does not have an adjustable stopping (cut-out) pressure. According to the product description, the device automatically deactivates the pump when the water flow stops or drops below 2 liters per minute.
The stopping pressure is determined by the maximum pressure your specific pump can reach at zero flow. If you need to change the restart (cut-in) pressure, please note that this is factory-set and depends on the specific model version you purchased:
Because the device relies on a flow sensor to stop the pump rather than a pressure switch, there are no internal screws or settings to manually increase the shut-off pressure.
Read the full Q&A page
come ridurre la pressione di arresto della pompa?
How can I reduce the pump's stop pressure?
Based on the technical specifications for the Pedrollo EASYPRESS, the stop pressure (shut-off pressure) is not adjustable. The device is designed to deactivate the pump automatically when the water flow stops or drops below 2 liters per minute (2 l/min).
The EASYPRESS operates based on flow detection for stopping and a fixed pressure threshold for starting. While the restart pressure is factory-set (standard at 1.5 bar, with 0.8 bar or 2.2 bar versions available upon request), the stop pressure is always determined by the maximum pressure your specific pump can reach once the flow has ceased.
If you need to limit the maximum pressure in your system, you would typically need to install a separate pressure reducing valve on the delivery line or use a different type of controller with adjustable cut-out settings.
Read the full Q&A page